3,962
Views
107
CrossRef citations to date
0
Altmetric
Original

Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty

, , , &
Pages 697-705 | Received 15 Nov 2005, Accepted 06 Feb 2006, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (8)

Christopher Jantzen, Henrik L Jørgensen, Benn R Duus, Sune L Sporring & Jes B Lauritzen. (2013) Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties. Acta Orthopaedica 84:3, pages 229-236.
Read now
J Rituerto Sin, X Hu & N Emami. (2013) Tribology, corrosion and tribocorrosion of metal on metal implants. Tribology - Materials, Surfaces & Interfaces 7:1, pages 1-12.
Read now
Moeed Akbar, James M. Brewer & M. Helen Grant. (2011) Effect of chromium and cobalt ions on primary human lymphocytes in vitro. Journal of Immunotoxicology 8:2, pages 140-149.
Read now
Toby O Smith, Rachel Nichols, Simon T Donell & Caroline B Hing. (2010) The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review. Acta Orthopaedica 81:6, pages 684-695.
Read now
Jack Farr & William A. Jiranek. (2009) Sports After Knee Arthroplasty: Partial Versus Total Knee Arthroplasty. The Physician and Sportsmedicine 37:4, pages 53-61.
Read now
Enrique Gomez-Barrena, José-Antonio Puertolas, Luis Munuera & Yrjö T Konttinen. (2008) Update on UHMWPE research From the bench to the bedside. Acta Orthopaedica 79:6, pages 832-840.
Read now
Daniel Kluess, Carmen Zietz, Tobias Lindner, Wolfram Mittelmeier, Klaus-Peter Schmitz & Rainer Bader. (2008) Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter. Acta Orthopaedica 79:6, pages 748-754.
Read now
Sannakaisa Virtanen. (2006) Metal release mechanisms in hip replacement. Acta Orthopaedica 77:5, pages 695-696.
Read now

Articles from other publishers (99)

Nicole L. Pratt, Flavia M. Cicuttini, Yuanyuan Wang & Stephen E. Graves. (2022) No increased risk of cancer associated with metal-on-metal or ceramic-on-ceramic procedures compared to other bearing surfaces in patients with total hip arthroplasty: A nationwide linked registry cohort analysis of 167,837 patients. PLOS ONE 17:11, pages e0278241.
Crossref
Charlotte Lee & Michele Hu. (2021) Parkinsonism in a Patient With Metal on Metal Total Hip Replacement Related Elevated Serum Heavy Metal Levels. Cureus.
Crossref
Kathryn A. Whitehead, Mohamed El Mohtadi, Anthony J. Slate, Misha Vaidya & Joels Wilson-Nieuwenhuis. 2021. The Chemistry of Inorganic Biomaterials. The Chemistry of Inorganic Biomaterials 231 289 .
Annamaria Nicolli, Isabella Bortoletti, Stefano Maso & Andrea Trevisan. (2021) Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses. Medicina 57:2, pages 115.
Crossref
Fredrik Wahlqvist, Ing-Liss Bryngelsson, Håkan Westberg, Per Vihlborg & Lena Andersson. (2020) Dermal and inhalable cobalt exposure—Uptake of cobalt for workers at Swedish hard metal plants. PLOS ONE 15:8, pages e0237100.
Crossref
Eli J. CurryThinh T. LeRitopa DasKai KeElise M. SantorellaDebayon PaulMeysam T. ChorsiKhanh T. M. TranJeffrey BaroodyEmily R. BorgesBrian KoAsiyeh GolabchiXiaonan XinDavid RoweLixia YueJianlin FengM. Daniela Morales-AcostaQian WuI-Ping Chen, X. Tracy CuiJoel PachterThanh D. Nguyen. (2019) Biodegradable nanofiber-based piezoelectric transducer. Proceedings of the National Academy of Sciences 117:1, pages 214-220.
Crossref
J. Huang, X. Li & Z.X. Guo. 2020. Biocompatibility and Performance of Medical Devices. Biocompatibility and Performance of Medical Devices 23 46 .
Christoph Bauer, Christoph Stotter, Vivek Jeyakumar, Eugenia Niculescu-Morzsa, Bojana Simlinger, Manel Rodríguez Ripoll, Thomas Klestil, Friedrich Franek & Stefan Nehrer. (2019) Concentration-Dependent Effects of Cobalt and Chromium Ions on Osteoarthritic Chondrocytes. CARTILAGE, pages 194760351988938.
Crossref
Pierre-Emmanuel Ridon, Sophie Putman, Henri Migaud, Charles Berton, Gilles Pasquier & Julien Girard. (2019) Étude comparative à long terme du couple métal-métal en grand diamètre : resurfaçage versus prothèse totale à grand diamètre du couple Durom™. Revue de Chirurgie Orthopédique et Traumatologique 105:5, pages 600-605.
Crossref
Pierre-Emmanuel Ridon, Sophie Putman, Henri Migaud, Charles Berton, Gilles Pasquier & Julien Girard. (2019) Long-term comparative study of large-diameter metal-on-metal bearings: Resurfacing versus total arthroplasty with large-diameter Durom™ bearing. Orthopaedics & Traumatology: Surgery & Research 105:5, pages 943-948.
Crossref
J.S. Hayes & R.G. Richards. 2019. Encyclopedia of Biomedical Engineering. Encyclopedia of Biomedical Engineering 257 269 .
Shayne C. GadJoAnn C. L. Schuh. 2019. Integrated Safety and Risk Assessment for Medical Devices and Combination Products. Integrated Safety and Risk Assessment for Medical Devices and Combination Products 339 400 .
Dahe Li, Wenwen Tong, Denghui Liu, Yuming Zou, Chen Zhang & Weidong Xu. (2017) Astaxanthin mitigates cobalt cytotoxicity in the MG-63 cells by modulating the oxidative stress. BMC Pharmacology and Toxicology 18:1.
Crossref
Xian Huang. 2017. Bioresorbable Materials and Their Application in Electronics. Bioresorbable Materials and Their Application in Electronics.
Michael Hahn, Björn Busse, Mathias Procop, Jozef Zustin, Michael Amling & Alexander Katzer. (2017) Cobalt deposition in mineralized bone tissue after metal-on-metal hip resurfacing: Quantitative μ-X-ray-fluorescence analysis of implant material incorporation in periprosthetic tissue. Journal of Biomedical Materials Research Part B: Applied Biomaterials 105:7, pages 1855-1862.
Crossref
Matthias C.M. Klotz, Sebastian Jäger, Jan-Philippe Kretzer, Nicholas A. Beckmann, Marc Thomsen & Rudi G. Bitsch. (2018) Cementing a Polyethylene Cup into a Well Fixed Acetabular Metal-on-Metal Resurfacing Component? An Experimental Investigation. HIP International 27:4, pages 373-377.
Crossref
Emily E. Hoffman, Alex Lin, Yifeng Liao & Laurence D. Marks. (2016) Grain Boundary Assisted Crevice Corrosion in CoCrMo Alloys. CORROSION 72:11, pages 1445-1461.
Crossref
Gavin Ring, John O'Mullane, Alan O'Riordan & Ambrose Furey. (2016) Trace metal determination as it relates to metallosis of orthopaedic implants: Evolution and current status. Clinical Biochemistry 49:7-8, pages 617-635.
Crossref
Joong-Myung Lee. (2016) The Current Concepts of Total Hip Arthroplasty. Hip & Pelvis 28:4, pages 191.
Crossref
N. Bizzotto, A. Sandri, G. Trivellin, B. Magnan, G.M. Micheloni, A. Zamò, P. Bernardi, A. Sbarbati & D. Regis. (2015) Chromium-induced diffuse dermatitis with lymph node involvement resulting from Langerhans cell histiocytosis after metal-on-metal hip resurfacing. British Journal of Dermatology 172:6, pages 1633-1636.
Crossref
Qizhi Chen & George A. Thouas. (2015) Metallic implant biomaterials. Materials Science and Engineering: R: Reports 87, pages 1-57.
Crossref
Hyun-Jung Choi, Seung-Jae Lim, Youn-Soo Park & Soo-Youn Lee. (2015) Simple and robust ICP-MS method for simultaneous determination of serum Co and Cr in routine clinical practice. Clinica Chimica Acta 439, pages 91-96.
Crossref
A.J. Hart, S.A. Sabah, B. Sampson, J.A. Skinner, J.J. Powell, L. Palla, K.J.J. Pajamäki, T. Puolakka, A. Reito & A. Eskelinen. (2014) Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses. Journal of Bone and Joint Surgery 96:13, pages 1091-1099.
Crossref
Michel J. Le Duff, Alicia J. Johnson & Harlan C. Amstutz. (2018) Do Hardened Femoral Heads Reduce Blood Metal Ion Concentrations after Hip Resurfacing?. HIP International 24:4, pages 327-332.
Crossref
Matevž Topolovec, Andrej Cör & Ingrid Milošev. (2014) Metal-on-metal vs. metal-on-polyethylene total hip arthroplasty tribological evaluation of retrieved components and periprosthetic tissue. Journal of the Mechanical Behavior of Biomedical Materials 34, pages 243-252.
Crossref
Henryk Matusiewicz. (2014) Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review. Acta Biomaterialia 10:6, pages 2379-2403.
Crossref
Mariam Al-Hamad, Michel J. Le Duff, Karren M. Takamura & Harlan C. Amstutz. (2014) Acetabular Component Thickness Does Not Affect Mid-term Clinical Results in Hip Resurfacing. Clinical Orthopaedics and Related Research? 472:5, pages 1528-1534.
Crossref
Pooja Panigrahi, Yifeng Liao, Mathew T. Mathew, Alfons Fischer, Markus A. Wimmer, Joshua J. Jacobs & Laurence D. Marks. (2014) Intergranular pitting corrosion of CoCrMo biomedical implant alloy. Journal of Biomedical Materials Research Part B: Applied Biomaterials 102:4, pages 850-859.
Crossref
Maria Burbano, Robert Russell, Michael Huo, Robert Welch, Diana Roy & Danieli Rodrigues. (2014) Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris. Materials 7:3, pages 1866-1879.
Crossref
Yoshimitsu Okazaki. (2014) Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator. Journal of the Mechanical Behavior of Biomedical Materials 31, pages 152-163.
Crossref
Zhefeng Chen, Zhen Wang, Qing Wang, Weiding Cui, Feng Liu & Weimin Fan. (2014) Changes in Early Serum Metal Ion Levels and Impact on Liver, Kidney, and Immune Markers Following Metal-on-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 29:3, pages 612-616.
Crossref
Jelle J. Halma, Daniel A. Godefrooij, Rienk Eshuis, Steven M. van Gaalen & Arthur de Gast. (2014) Excellent Survivorship of the Morscher Monoblock Cup With a 28-mm Metasul-on-Metasul Bearing at a Mean of 5-Year Follow-Up. The Journal of Arthroplasty 29:2, pages 405-409.
Crossref
S.H. Riza, S.H. Masood & C. Wen. 2014. Comprehensive Materials Processing. Comprehensive Materials Processing 285 301 .
Ciro Villani & Alessandro Calistri. 2014. Imaging of Prosthetic Joints. Imaging of Prosthetic Joints 53 59 .
Maik Stiehler, Stephan Kirschner & Klaus-Peter Günther. 2014. European Surgical Orthopaedics and Traumatology. European Surgical Orthopaedics and Traumatology 2621 2634 .
H. John Cooper & Joshua J. Jacobs. 2014. Metal-on-Metal Bearings. Metal-on-Metal Bearings 135 151 .
John J. Devlin, Adam C. Pomerleau, Jeffrey Brent, Brent W. Morgan, Scott Deitchman & Michael Schwartz. (2013) Clinical Features, Testing, and Management of Patients with Suspected Prosthetic Hip-Associated Cobalt Toxicity: a Systematic Review of Cases. Journal of Medical Toxicology 9:4, pages 405-415.
Crossref
Albrecht Hartmann, Franziska Hannemann, Jörg Lützner, Andreas Seidler, Hans Drexler, Klaus-Peter Günther & Jochen Schmitt. (2013) Metal Ion Concentrations in Body Fluids after Implantation of Hip Replacements with Metal-on-Metal Bearing – Systematic Review of Clinical and Epidemiological Studies. PLoS ONE 8:8, pages e70359.
Crossref
M. Thomsen, J.P. Kretzer, V. Krenn & P. Thomas. (2013) Unterschiedliche Erscheinungsbilder bei Patienten mit Metall-Metall-Gleitpaarungs-ProthesenDifferent symptoms in patients with prostheses with metal-metal bearings. Der Orthopäde 42:8, pages 637-642.
Crossref
Richard M.R. Dyrkacz, Jan-M. Brandt, Olanrewaju A. Ojo, Thomas R. Turgeon & Urs P. Wyss. (2013) The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints. The Journal of Arthroplasty 28:6, pages 1036-1040.
Crossref
Yoshimitsu Okazaki & Emiko Gotoh. (2013) Metal ion effects on different types of cell line, metal ion incorporation into L929 and MC3T3-E1 cells, and activation of macrophage-like J774.1 cells. Materials Science and Engineering: C 33:4, pages 1993-2001.
Crossref
James P. Yoon, Michel J. Le Duff, Alicia J. Johnson, Karren M. Takamura, Edward Ebramzadeh & Harlan C. Amstutz. (2012) Contact Patch to Rim Distance Predicts Metal Ion Levels in Hip Resurfacing. Clinical Orthopaedics and Related Research® 471:5, pages 1615-1621.
Crossref
Harlan C. Amstutz, Patricia A. Campbell, Frederick J. Dorey, Alicia J. Johnson, Anastasia K. Skipor & Joshua J. Jacobs. (2013) Do Ion Concentrations after Metal-on-Metal Hip Resurfacing Increase Over Time? A Prospective Study. The Journal of Arthroplasty 28:4, pages 695-700.
Crossref
Matthew F. Gornet, J. K. Burkus, M. L. Harper, F. W. Chan, A. K. Skipor & J. J. Jacobs. (2012) Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty. European Spine Journal 22:4, pages 741-746.
Crossref
C. Van Der Straeten & K. De Smet. 2013. The Hip Resurfacing Handbook. The Hip Resurfacing Handbook 506 520 .
R. Gill, P. Campbell & K. De Smet. 2013. The Hip Resurfacing Handbook. The Hip Resurfacing Handbook 267 278 .
K.J. Hamelynck & R.G. Woering. 2013. The Hip Resurfacing Handbook. The Hip Resurfacing Handbook 3 10 .
W Maurer-Ertl, J Friesenbichler, P Sadoghi, M Pechmann, M Trennheuser & A Leithner. (2012) Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up. BMC Musculoskeletal Disorders 13:1.
Crossref
Walter van der Weegen, Henk J Hoekstra, Thea Sijbesma, Shennah Austen & Rudolf W Poolman. (2012) Hip resurfacing in a district general hospital: 6-year clinical results using the ReCap hip resurfacing system. BMC Musculoskeletal Disorders 13:1.
Crossref
Hugo C van der Veen, Inge van den Akker-Scheek, Sjoerd K Bulstra & Jos JAM van Raay. (2012) Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial. BMC Musculoskeletal Disorders 13:1.
Crossref
Nicola Maffulli, Angelo Del Buono & Vincenzo Denaro. (2012) Hip artroplasty: A transient reason not to be pregnant. The Surgeon 10:6, pages 347-349.
Crossref
Heiko Meyer, Tina Mueller, Gesine Goldau, Kathrin Chamaon, Marcel Ruetschi & Christoph H. Lohmann. (2012) Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties. Clinical Orthopaedics and Related Research? 470:11, pages 3101-3108.
Crossref
Wan-Seob Cho, Kenneth Dart, Dominika J Nowakowska, Xiaozhong Zheng, Ken Donaldson & Sarah EM Howie. (2012) Adjuvanticity and toxicity of cobalt oxide nanoparticles as an alternative vaccine adjuvant. Nanomedicine 7:10, pages 1495-1505.
Crossref
Juliane Fritzsche, Cornelia Borisch & Christof Schaefer. (2012) Case Report: High Chromium and Cobalt Levels in a Pregnant Patient with Bilateral Metal-on-Metal Hip Arthroplasties. Clinical Orthopaedics and Related Research® 470:8, pages 2325-2331.
Crossref
William P. Barrett, Kirk A. Kindsfater & James P. Lesko. (2012) Large-Diameter Modular Metal-on-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 27:6, pages 976-983.e1.
Crossref
Masahiro Hasegawa, Kakunoshin Yoshida, Hiroki Wakabayashi & Akihiro Sudo. (2012) Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 27:6, pages 990-996.
Crossref
Barry Sampson & Alister Hart. (2012) Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 49:2, pages 118-131.
Crossref
Joerg Friesenbichler, Werner Maurer-Ertl, Patrick Sadoghi, Thomas Lovse, Reinhard Windhager & Andreas Leithner. (2011) Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis. International Orthopaedics 36:3, pages 539-544.
Crossref
J. Huang & Z.X. Guo. 2012. Biocompatibility and Performance of Medical Devices. Biocompatibility and Performance of Medical Devices 37 61 .
Sanket R. Diwanji, Pascal‐André Vendittoli & Martin Lavigne. 2011. Evidence‐Based Orthopedics. Evidence‐Based Orthopedics 137 152 .
Rhett K. Hallows, Christopher E. Pelt, Jill A. Erickson & Christopher L. Peters. (2011) Serum Metal Ion Concentration: Comparison Between Small and Large Head Metal-on-Metal Total Hip Arthroplasty. The Journal of Arthroplasty 26:8, pages 1176-1181.
Crossref
Ryan G. Molli, Adolph V. LombardiJr.Jr., Keith R. Berend, Joanne B. Adams & Michael A. Sneller. (2011) Metal-on-Metal vs Metal-on-Improved Polyethylene Bearings in Total Hip Arthroplasty. The Journal of Arthroplasty 26:6, pages 8-13.
Crossref
U. E. Pazzaglia, P. Apostoli, T. Congiu, S. Catalani, M. Marchese & G. Zarattini. (2011) Cobalt, chromium and molybdenum ions kinetics in the human body: data gained from a total hip replacement with massive third body wear of the head and neuropathy by cobalt intoxication. Archives of Orthopaedic and Trauma Surgery 131:9, pages 1299-1308.
Crossref
Nils Jacobsen. (2011) Munnhulekreft, dentale biomaterialer og inflammasjon. Den norske tannlegeforenings Tidende 121:10.
Crossref
Martin Lavigne, Etienne L. Belzile, Alain Roy, François Morin, Traian Amzica & Pascal-André Vendittoli. (2011) Comparison of Whole-Blood Metal Ion Levels in Four Types of Metal-on-Metal Large-Diameter Femoral Head Total Hip Arthroplasty: The Potential Influence of the Adapter Sleeve. Journal of Bone and Joint Surgery 93:Supplement_2, pages 128-136.
Crossref
Paul R. Kim, Paul E. Beaulé, Michael Dunbar, Joshua K.L. Lee, Nicholas Birkett, Michelle C. Turner, Nagarajkumar Yenugadhati, Vic Armstrong & Daniel Krewski. (2011) Cobalt and Chromium Levels in Blood and Urine Following Hip Resurfacing Arthroplasty with the Conserve Plus Implant. Journal of Bone and Joint Surgery 93:Supplement_2, pages 107-117.
Crossref
Grace A. Afolaranmi, Catherine Henderson & M. Helen Grant. (2011) Effect of chromium and cobalt ions on phase I and phase II enzymatic activities in vitro in freshly isolated rat hepatocytes. Toxicology in Vitro 25:1, pages 125-130.
Crossref
Jing Yang, Bin Shen, ZongKe Zhou, Fuxing Pei & PengDe Kang. (2011) Changes in Cobalt and Chromium Levels After Metal-on-Metal Hip Resurfacing in Young, Active Chinese Patients. The Journal of Arthroplasty 26:1, pages 65-70.e1.
Crossref
A. Moroni, L. Savarino, M. Hoque, M. Cadossi & N. Baldini. (2010) Do Ion Levels In Hip Resurfacing Differ From Metal-on-metal THA at Midterm?. Clinical Orthopaedics and Related Research® 469:1, pages 180-187.
Crossref
Karel J. Hamelynck, David J. Woodnutt, Robin Rice & Genio Bongaerts. 2011. Tribology in Total Hip Arthroplasty. Tribology in Total Hip Arthroplasty 113 119 .
C. Delaunay, I. Petit, I.D. Learmonth, P. Oger & P.-A. Vendittoli. (2010) Couple de frottement métal–métal des prothèses totales de hanches: surveillance du relargage des ions métalliques cobalt et chrome. Revue de Chirurgie Orthopédique et Traumatologique 96:8, pages 990-1001.
Crossref
C. Delaunay, I. Petit, I.D. Learmonth, P. Oger & P.A. Vendittoli. (2010) Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern. Orthopaedics & Traumatology: Surgery & Research 96:8, pages 894-904.
Crossref
Takao Imanishi, Masahiro Hasegawa & Akihiro Sudo. (2010) Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery 130:12, pages 1447-1450.
Crossref
Ajay Malviya, Jayasree Ramaskandhan, James P. Holland & Elizabeth A. Lingard. (2010) Metal-on-Metal Total Hip Arthroplasty. Journal of Bone and Joint Surgery 92:7, pages 1675-1683.
Crossref
P.-A. VendittoliA. RoyS. MottardJ. GirardD. LusignanM. Lavigne. (2010) Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations. The Journal of Bone and Joint Surgery. British volume 92-B:1, pages 12-19.
Crossref
Mauro Cataldi & Anna Cavaccini. 2010. xPharm: The Comprehensive Pharmacology Reference. xPharm: The Comprehensive Pharmacology Reference 1 26 .
Jeannette Ø. Penny & Soren Overgaard. (2009) Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?. Journal of Biomedical Materials Research Part B: Applied Biomaterials 92B:1, pages 1-4.
Crossref
Vijay Krishna Raghunathan, Elizabeth M. Ellis & M. Helen Grant. (2009) Response to chronic exposure to hexavalent chromium in human monocytes. Toxicology in Vitro 23:4, pages 647-652.
Crossref
Alexander Zeh, Claudia Becker, Michael Planert, Peter Lattke & David Wohlrab. (2008) Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick™ type artificial lumbar disc (Medtronic Sofamor Danek). Archives of Orthopaedic and Trauma Surgery 129:6, pages 741-746.
Crossref
Anton H. Hosman, Henny C. van der Mei, Sjoerd K. Bulstra, Henk J. Busscher & Daniëlle Neut. (2008) Metal‐on‐metal bearings in total hip arthroplasties: Influence of cobalt and chromium ions on bacterial growth and biofilm formation. Journal of Biomedical Materials Research Part A 88A:3, pages 711-716.
Crossref
RICHARD A. HOCKING & STEVEN J. MACDONALD. 2009. Evidence-Based Orthopaedics. Evidence-Based Orthopaedics 565 571 .
J. Girard, M. Lavigne, P.A. Vendittoli & H. Migaud. (2008) Resurfaçage de hanche : état actuel des connaissances. Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur 94:8, pages 715-730.
Crossref
B. Sonny Bal, Ashok Khandkar, R. Lakshminarayanan, Ian Clarke, Aaron A. Hoffman & Mohamed N. Rahaman. (2008) Testing of silicon nitride ceramic bearings for total hip arthroplasty. Journal of Biomedical Materials Research Part B: Applied Biomaterials 87B:2, pages 447-454.
Crossref
R. De HaanC. PattynH. S. GillD. W. MurrayP. A. CampbellK. De Smet. (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. The Journal of Bone and Joint Surgery. British volume 90-B:10, pages 1291-1297.
Crossref
Christian Heisel, Nikolaus Streich, Michael Krachler, Eike Jakubowitz & J. Philippe Kretzer. (2008) Characterization of the Running-in Period in Total Hip Resurfacing Arthroplasty: An in Vivo and in Vitro Metal Ion Analysis. Journal of Bone and Joint Surgery 90:Supplement_3, pages 125-133.
Crossref
R. Bader, D. Klüß, L. Gerdesmeyer & E. Steinhauser. (2008) Biomechanische Aspekte zur Implantatverankerung und Kinematik von OberflächenersatzhüftendoprothesenBiomechanical aspects of the implant fixation and kinematics of hip resurfacing systems. Der Orthopäde 37:7, pages 634-643.
Crossref
K.-P. Günther, W.-C. Witzleb, M. Stiehler & S. Kirschner. (2008) Revisionschirurgie des OberflächenersatzesRevision surgery of hip resurfacing. Der Orthopäde 37:7, pages 685-694.
Crossref
Antonio Moroni, Lucia Savarino, Matteo Cadossi, Nicola Baldini & Sandro Giannini. (2008) Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?. Clinical Orthopaedics and Related Research 466:3, pages 700-707.
Crossref
Chang Ich Hur, Taek Rim Yoon, Sang Gwon Cho, Eun Kyoo Song & Jong Keun Seon. (2008) Serum Ion Level After Metal-on-metal THA in Patients With Renal Failure. Clinical Orthopaedics and Related Research 466:3, pages 696-699.
Crossref
L. Lidgren. (2008) Chronic inflammation, joint replacement and malignant lymphoma. The Journal of Bone and Joint Surgery. British volume 90-B:1, pages 7-10.
Crossref
Andrew Taylor, Simon Branch, Martin P. Day, Marina Patriarca & Mark White. (2008) Atomic spectrometry update. Clinical and biological materials, foods and beverages. Journal of Analytical Atomic Spectrometry 23:4, pages 595.
Crossref
Mustafa Gokhan Bilgili. (2008) Letters to the Editor. The Journal of Arthroplasty 23:1, pages 156.
Crossref
Patricia A. Campbell & Karren Midori Takamura. 2008. Hip Resurfacing. Hip Resurfacing 133 148 .
Michael A Mont, Thorsten M Seyler, Slif D Ulrich, Paul E Beaule, Harold S Boyd, Michael J Grecula, Victor M Goldberg, William R Kennedy, David R Marker, Thomas P Schmalzried, Edward A Sparling, Thomas Parker Vail & Harlan C Amstutz. (2007) Effect of Changing Indications and Techniques on Total Hip Resurfacing. Clinical Orthopaedics & Related Research 465, pages 63-70.
Crossref
Masanori Ogawa, Yoshiaki Nakajima & Yoko Endo. (2007) Four Cases of Chemical Burns Thought to Be Caused by Exposure to Chromic Acid Mist. Journal of Occupational Health 49:5, pages 402-404.
Crossref
Joerg Luetzner, Frank Krummenauer, Attila Michael Lengel, Joerg Ziegler & Wolf-Christoph Witzleb. (2007) Serum Metal Ion Exposure after Total Knee Arthroplasty. Clinical Orthopaedics & Related Research 461, pages 136-142.
Crossref
J. Ziegler, M. Amlang, M. Bottesi, S. Kirschner, W.-C. Witzleb & K.-P. Günther. (2007) Ergebnisse endoprothetischer Versorgung bei Patienten vor dem 50. LebensjahrResults for endoprosthetic care in patients younger than 50 years. Der Orthopäde 36:4, pages 325-336.
Crossref
Ian D Learmonth & C Patrick Case. (2007) Metallic debris from orthopaedic implants. The Lancet 369:9561, pages 542-544.
Crossref
Francesco Benazzo, Paolo Dalla Pria, Wolfram Mittelmeier, D. Tigani, C. Zorzi, D. Ganzer, C. H. Lohmann, E. G. Cimbrelo, C. R. Merchan, E. M. Saura, A. U. Lizaur, J. F. Couceiro & S. Burelli. 2007. Bioceramics and Alternative Bearings in Joint Arthroplasty. Bioceramics and Alternative Bearings in Joint Arthroplasty 145 148 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.