1,663
Views
11
CrossRef citations to date
0
Altmetric
Original Articles

Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty

A retrieval analysis of 102 inlays

, , , , , & show all
Pages 62-69 | Received 06 Mar 2016, Accepted 31 Jul 2016, Published online: 26 Oct 2016

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Koen T van Hamersveld, Perla J Marang–van de Mheen, Lennard A Koster, Rob G H H Nelissen, Sören Toksvig-Larsen & Bart L Kaptein. (2019) Marker-based versus model-based radiostereometric analysis of total knee arthroplasty migration: a reanalysis with comparable mean outcomes despite distinct types of measurement error. Acta Orthopaedica 90:4, pages 366-372.
Read now

Articles from other publishers (10)

Yushy Zhou, Dylan Harries & James D. Stoney. (2023) A Polished Cobalt-Chrome Baseplate is Not Associated with a Lower Revision Rate than Matt Titanium in a Single Total Knee Arthroplasty Implant System with Identical Baseplate Design. The Journal of Arthroplasty.
Crossref
Monu Jabbal, A Hamish RW Simpson & Phil Walmsley. (2023) Mechanisms of bone loss in revision total knee arthroplasty and current treatment options. Orthopedic Reviews 15.
Crossref
Masahiro Hasegawa, Shine Tone, Yohei Naito & Akihiro Sudo. (2023) Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties. Materials 16:6, pages 2140.
Crossref
Anirudh Sharma, Vijay Killampalli & Arpit Patel. (2022) Locking mechanism failure between tibial baseplate and polyethylene insert in cruciate retaining total knee arthroplasty. Journal of Clinical Orthopaedics and Trauma 34, pages 102013.
Crossref
Allen D. Nicholson, Joshua I. Mathew, Chelsea N. Koch, Andreas Kontaxis, Timothy Wright, Samuel A. Taylor, Theodore A. Blaine, Joshua S. Dines, David M. Dines, Michael C. Fu, Russell F. Warren & Lawrence V. Gulotta. (2022) Backside polyethylene wear in reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery 31:3, pages 545-552.
Crossref
Rohan M. Bhalekar, Matthew E. Nargol, Nish Shyam, Antoni V. F. Nargol, Stephen R. Wells, Ryan Collier, Moreica Pabbruwe, Thomas J. Joyce & David J. Langton. (2021) Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial inserts. The Bone & Joint Journal 103-B:12, pages 1791-1801.
Crossref
Dominic T. Mathis, Joshua Schmidli, Michael T. Hirschmann, Felix Amsler, Johann Henckel, Harry Hothi & Alister Hart. (2021) Comparative retrieval analysis of antioxidant polyethylene: bonding of vitamin-E does not reduce in-vivo surface damage. BMC Musculoskeletal Disorders 22:1.
Crossref
Steffen Braun, Maximilian Uhler, Therese Bormann, Stefan Schroeder, Sebastian Jaeger, Robert Sonntag & Jan Philippe Kretzer. (2021) Backside wear in total knee replacement: A new quantitative measurement method and a comparison of polished cobalt-chromium tibial trays with titanium tibial trays. Wear 466-467, pages 203552.
Crossref
Łukasz Łapaj & Justyna Rozwalka. (2020) Retrieval analysis of TiN (titanium nitride) coated knee replacements: Coating wear and degradation in vivo. Journal of Biomedical Materials Research Part B: Applied Biomaterials 108:4, pages 1251-1261.
Crossref
Zhenxian Chen, Jing Zhang, Yongchang Gao, Shibin Chen, Xuan Zhang & Zhongmin Jin. (2019) Effects of interference assembly of a tibial insert on the tibiofemoral contact mechanics in total knee replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 233:9, pages 948-953.
Crossref