5,464
Views
27
CrossRef citations to date
0
Altmetric
Original Article

Cobalt-chromium alloys in fixed prosthodontics in Sweden

ORCID Icon, , &
Pages 53-62 | Received 22 Jun 2017, Accepted 25 Jul 2017, Published online: 11 Aug 2017

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (3)

Uva Narayanan C & Suya Prem Anand P. (2023) Selective laser melting and post-processing stages for enhancing the material behavior of cobalt-chromium alloy in total hip replacement: a review. Materials and Manufacturing Processes 38:5, pages 495-515.
Read now
Burcu Yuksel & Serap Arsal Yildirim. (2022) Determination of cytogenetic abnormalities in buccal mucosa of dental laboratory technicians. Archives of Environmental & Occupational Health 77:2, pages 165-172.
Read now
Ketil Hegerstrøm Haugli, Morten Syverud & Jan Tore Samuelsen. (2020) Ion release from three different dental alloys – effect of dynamic loading and toxicity of released elements. Biomaterial Investigations in Dentistry 7:1, pages 71-79.
Read now

Articles from other publishers (24)

Maria Kassapidou, Victoria Franke Stenport, Carina B. Johansson, Morten Syverud, Petra Hammarström Johansson, Johan Börjesson & Lars Hjalmarsson. (2023) Cobalt-chromium alloys in fixed prosthodontics: Investigations of mechanical properties and microstructure. The Journal of Prosthetic Dentistry.
Crossref
P. E. Lushchik, I. V. Rafalski, V. T. Minchenya, L. P. Dolgi, A. V. Zablotski & A. Yu. Korolev. (2023) Structure and properties of Co‑Cr alloys for biocompatible medical products. Litiyo i Metallurgiya (FOUNDRY PRODUCTION AND METALLURGY):4, pages 108-114.
Crossref
Adina Oana Armencia, Magda Antohe, Cătălina Iulia Săveanu, Dana Budală, Carina Balcoș, Otilia-Sanda Prelipceanu, Marius Prelipceanu & Dragoș Ionuț Vicoveanu. (2022) Analytical Study Regarding the Behavior of Cr-Co and Ni-Cr in Saliva. Medicina 58:11, pages 1524.
Crossref
Aswini K Kar, Purnendu Bhushan, Sadananda Hota, Anjana Raut, Nikita Jaiswal & Purna C Mishra. (2022) Stress Distribution Analysis of Implant-supported Fixed Prosthesis Framework Material in Peri-implant Bone Using Optimization: A 3D FEA Study. World Journal of Dentistry 13:S1, pages S58-S65.
Crossref
Brigitte Grosgogeat, Alina Vaicelyte, Rémy Gauthier, Christine Janssen & Marc Le Borgne. (2022) Toxicological Risks of the Cobalt–Chromium Alloys in Dentistry: A Systematic Review. Materials 15:17, pages 5801.
Crossref
Faris A. Alshahrani, Fatemah AlToraibily, Maryam Alzaid, Amr A. Mahrous, Maram A. Al Ghamdi & Mohammed M. Gad. (2022) An Updated Review of Salivary pH Effects on Polymethyl Methacrylate (PMMA)-Based Removable Dental Prostheses. Polymers 14:16, pages 3387.
Crossref
Sheida Nilsson, Victoria Franke Stenport, Marco Nilsson & Catharina Göthberg. (2022) A retrospective clinical study of fixed tooth- and implant-supported prostheses in titanium and cobalt-chromium-ceramic: 5–9-year follow-up. Clinical Oral Investigations 26:10, pages 6097-6103.
Crossref
Fellwa AlRasheed & Khalid AlWazzan. (2022) The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses. The Saudi Dental Journal 34:4, pages 288-297.
Crossref
Willi Andrei Uriciuc, Adina Bianca Boșca, Anida-Maria Băbțan, Horațiu Vermeșan, Cecilia Cristea, Mihaela Tertiș, Petru Pășcuță, Gheorghe Borodi, Maria Suciu, Lucian Barbu-Tudoran, Cătălin Ovidiu Popa & Aranka Ilea. (2022) Study on the Surface of Cobalt-Chromium Dental Alloys and Their Behavior in Oral Cavity as Cast Materials. Materials 15:9, pages 3052.
Crossref
Lia Stanciu & Susana Diaz-Amaya. 2022. Introductory Biomaterials. Introductory Biomaterials 31 55 .
Vinay Sivaswamy & Sahana Vasudevan. 2022. Dental Implants and Oral Microbiome Dysbiosis. Dental Implants and Oral Microbiome Dysbiosis 1 12 .
Alireza Hashemi Ashtiani, Nahal Mardasi & Amirhossein Fathi. (2021) Effect of multiple firings on the shear bond strength of presintered cobalt-chromium alloy and veneering ceramic. The Journal of Prosthetic Dentistry.
Crossref
Willi Andrei Uriciuc, Adina Bianca Boșca, Anida Maria Babtan, Claudia Nicoleta Feurden, Anca Ionel, Horațiu Vermeșan, Cătălin Ovidiu Popa & Aranka Ilea. (2021) Optimization of the Manufacturing Process by Molding Cobalt-Chrome Alloys in Assembled Dental Frameworks. Prosthesis 3:3, pages 245-260.
Crossref
Farah Bechir, Simona Maria Bataga, Elena Ungureanu, Diana Maria Vranceanu, Mariana Pacurar, Edwin Sever Bechir & Cosmin Mihai Cotrut. (2021) Experimental Study Regarding the Behavior at Different pH of Two Types of Co-Cr Alloys Used for Prosthetic Restorations. Materials 14:16, pages 4635.
Crossref
Luis Fernando Velásquez-GarcíaYosef Kornbluth. (2021) Biomedical Applications of Metal 3D Printing. Annual Review of Biomedical Engineering 23:1, pages 307-338.
Crossref
Patrick Hegele, Jonas von Kobylinski, Leonhard Hitzler, Christian Krempaszky & Ewald Werner. (2021) In-Situ XRD Study of Phase Transformation Kinetics in a Co-Cr-W-Alloy Manufactured by Laser Powder-Bed Fusion. Crystals 11:2, pages 176.
Crossref
Sarah Hashemi Astaneh, Leonardo P. Faverani, Cortino Sukotjo & Christos G. Takoudis. (2021) Atomic layer deposition on dental materials: Processing conditions and surface functionalization to improve physical, chemical, and clinical properties - A review. Acta Biomaterialia 121, pages 103-118.
Crossref
Alina Vaicelyte, Christine Janssen, Marc Le Borgne & Brigitte Grosgogeat. (2020) Cobalt–Chromium Dental Alloys: Metal Exposures, Toxicological Risks, CMR Classification, and EU Regulatory Framework. Crystals 10:12, pages 1151.
Crossref
Maria Kassapidou, Lars Hjalmarsson, Carina B. Johansson, Petra Hammarström Johansson, Else Morisbak, Ann Wennerberg & Victoria Franke Stenport. (2020) Cobalt–chromium alloys fabricated with four different techniques: Ion release, toxicity of released elements and surface roughness. Dental Materials 36:11, pages e352-e363.
Crossref
Maryam Tilton, April Armstrong, Jennifer Sanville, Matthew Chin, Michael W. Hast, Gregory S. Lewis & Guha P. Manogharan. (2019) Biomechanical Testing of Additive Manufactured Proximal Humerus Fracture Fixation Plates. Annals of Biomedical Engineering 48:1, pages 463-476.
Crossref
Yu. G. Aliakseyeu, A. Yu. Korolyov & V. S. Niss. (2019) Electrolytic-plasma polishing of cobalt-chromium alloys for medical products. Proceedings of the National Academy of Sciences of Belarus, Physical-Technical Series 64:3, pages 296-303.
Crossref
Ragala Jhansi, Allu Venkata Reddy, Kasina Sitaram Prasad, Yarlagadda Siva Kiran & Dola Sundeep. (2019) A Comparative Assessment of Flexural Bond Strength of Ni–Cr Metal–Ceramic Alloy on Repeated Castings. International Journal of Prosthodontics and Restorative Dentistry 9:3, pages 70-76.
Crossref
Morgan Lowther, Sophie Louth, Amy Davey, Azad Hussain, Paola Ginestra, Luke Carter, Neil Eisenstein, Liam Grover & Sophie Cox. (2019) Clinical, industrial, and research perspectives on powder bed fusion additively manufactured metal implants. Additive Manufacturing 28, pages 565-584.
Crossref
Hesham Nouh. 2019. Digital Restorative Dentistry. Digital Restorative Dentistry 207 227 .