216
Views
33
CrossRef citations to date
0
Altmetric
Original Articles

ELECTROCHEMICAL OXIDATION OF MELOXICAM AND ITS DETERMINATION IN TABLET DOSAGE FORM

, , &
Pages 739-748 | Received 15 Sep 2000, Accepted 18 Dec 2000, Published online: 02 Feb 2007

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Bengi Uslu & Sibel A. Ozkan. (2007) Electroanalytical Application of Carbon Based Electrodes to the Pharmaceuticals. Analytical Letters 40:5, pages 817-853.
Read now

Articles from other publishers (32)

Akshay Krishnakumar, Rupesh Kumar Mishra, Sachin Kadian, Amin Zareei, Ulisses Heredia Rivera & Rahim Rahimi. (2022) Printed graphene-based electrochemical sensor with integrated paper microfluidics for rapid lidocaine detection in blood. Analytica Chimica Acta 1229, pages 340332.
Crossref
Renáta Šelešovská, Frederika Hlobeňová, Jana Skopalová, Petr Cankař, Lenka Janíková & Jaromíra Chýlková. (2020) Electrochemical oxidation of anti-inflammatory drug meloxicam and its determination using boron doped diamond electrode. Journal of Electroanalytical Chemistry 858, pages 113758.
Crossref
Nasr Y. Khalil & Khalid F. Aldosari. 2020. Profiles of Drug Substances, Excipients, and Related Methodology. Profiles of Drug Substances, Excipients, and Related Methodology 159 197 .
Leyla Karadurmus, I. Firat Sahin, Sevinc Kurbanoglu & Sibel A. Ozkan. (2019) Electrochemical Determination of Non-Steroidal Anti-Inflammatory Drugs. Current Analytical Chemistry 15:4, pages 485-501.
Crossref
Abdulbari Mahdi Mahood & Nahawnd H. Najm. (2019) Spectrophotometric Estamation of Meloxicam Using Charge Transfer Complex. IOP Conference Series: Materials Science and Engineering 571:1, pages 012081.
Crossref
Mehmet E. Eroğlu, Dilek E. Bayraktepe, Kamran Polat & Zehra Yazan. (2019) Electro-Oxidation Mechanism of Meloxicam and Electrochemical Sensing Platform Based on Graphene Nanoparticles for its Sensing Pharmaceutical Sample. Current Pharmaceutical Analysis 15:4, pages 346-354.
Crossref
Ghazal Ghobadpour, Fatemeh Farjami & Farshid Fasihi. (2018) Sensitive Electrochemical Monitoring of Piroxicam in Pharmaceuticals Using Carbon Ionic Liquid Electrode. Current Pharmaceutical Analysis 15:1, pages 45-50.
Crossref
K. Louati, I. Bargaoui & F. Safta. (2018) Development and validation of ultra-performance liquid chromatography method for the determination of meloxicam and its impurities in active pharmaceutical ingredients. Annales Pharmaceutiques Françaises 76:3, pages 187-200.
Crossref
Urooj Amjad, Aref Lashin, Rashda Abbasi, Usman Ali Rana, Nassir Al-Arifi, Gul Shahzada Khan, Saqib Ali, Heinz-Bernhard Kraatz & Afzal Shah. (2016) pH and Temperature Responsive Electrooxidation of Thiazole Derivatives and Preliminary Screening of Their Antioxidant Activity. Journal of The Electrochemical Society 163:5, pages H350-H358.
Crossref
Gabriela V. Ferrari, José Natera, M. Paulina Montaña, Vanesa Muñoz, Eduardo L. Gutiérrez, Walter Massad, Sandra Miskoski & Norman A. García. (2015) Scavenging of photogenerated ROS by Oxicams. Possible biological and environmental implications. Journal of Photochemistry and Photobiology B: Biology 153, pages 233-239.
Crossref
Nadereh Rahbar, Zahra Ramezani & Ahmad Babapour. (2015) Electro-Oxidation Mechanism and Direct Square-Wave Voltammetric Determination of Lidocaine With a Carbon-Paste Electrode. Jundishapur Journal of Natural Pharmaceutical Products 10:1.
Crossref
Nalini Kanta Sahoo, Madhusmita Sahu, Podilapu Srinivasa Rao, N Sandhya Rani, JNV Indira Devi & Goutam Ghosh. (2014) Validation of assay indicating method development of meloxicam in bulk and some of its tablet dosage forms by RP-HPLC. SpringerPlus 3:1.
Crossref
Mohammad Bagher Gholivand, Ghodratollah Malekzadeh & Ali Ashraf Derakhshan. (2014) Boehmite nanoparticle modified carbon paste electrode for determination of piroxicam. Sensors and Actuators B: Chemical 201, pages 378-386.
Crossref
Srikanth Cheemalapati, Balamurugan Devadas & Shen-Ming Chen. (2014) Novel poly- l -lysine/carboxyl-group enriched graphene oxide/modified electrode preparation, characterization and applications for the electrochemical determination of meloxicam in pharmaceutical tablets and blood serum . Anal. Methods 6:20, pages 8426-8434.
Crossref
Ali Babaei, Masoud Sohrabi & Mohammad Afrasiabi. (2012) A Sensitive Simultaneous Determination of Epinephrine and Piroxicam Using a Glassy Carbon Electrode Modified with a Nickel Hydroxide Nanoparticles/Multiwalled Carbon Nanotubes Composite. Electroanalysis 24:12, pages 2387-2394.
Crossref
Karel Vytras. 2012. Electroanalysis with Carbon Paste Electrodes. Electroanalysis with Carbon Paste Electrodes.
Mohammad Bagher Gholivand & Nashmil Karimian. (2011) Development of piroxicam sensor based on molecular imprinted polymer-modified carbon paste electrode. Materials Science and Engineering: C 31:8, pages 1844-1851.
Crossref
P. Prabhu, R. Suresh Babu & S. Sriman Narayanan. (2011) Amperometric determination of l-dopa by nickel hexacyanoferrate film modified gold nanoparticle graphite composite electrode. Sensors and Actuators B: Chemical 156:2, pages 606-614.
Crossref
S. I. M. Zayed. (2011) Differential Pulse Anodic Voltammetric Determination of Tiapride Hydrochloride in Pharmaceutical Preparation and Human Urine Using Carbon Paste Electrodes. Analytical Sciences 27:5, pages 535-539.
Crossref
Marion Coting Braga, Thais Boscolo Requeijo, Andressa Maia Cruz Franco, Nina Coichev & Horacio Dorigan Moya. (2011) Quantification of some nonsteroidal anti-inflammatory drugs as reducing agents of Cu(ii)/4,4′-dicarboxy-2,2′-biquinoline complexes in cationic micellar medium. Analytical Methods 3:7, pages 1637.
Crossref
Parandis Daneshgar, Parviz Norouzi, Mohammad Ganjali, Rasoul Dinarvand & Ali Moosavi-Movahedi. (2009) Determination of Diclofenac on a Dysprosium Nanowire- Modified Carbon Paste Electrode Accomplished in a Flow Injection System by Advanced Filtering. Sensors 9:10, pages 7903-7918.
Crossref
Huazhen Ye, Bin Qiu, Jing Chen, Jinming Lin & Guonan Chen. (2009) Flow-injection analysis for meloxicam based on tris(2,2′-bipyridine) ruthenium(II)-Ce(IV) chemiluminescent system. Luminescence 24:4, pages 260-265.
Crossref
Parandis Daneshgar, Parviz Norouzi, Mohammad Reza Ganjali & Faeze Dousty. (2009) A Dysprosium Nanowire Modified Carbon Paste Electrode for Determination of Nanomplar Level of Diphenhydramin by Continuous Square Wave Voltammetry in Flow Injection System. International Journal of Electrochemical Science 4:3, pages 444-457.
Crossref
Parandis Daneshgar, Parviz Norouzi, Mohammad Reza Ganjali, Amin Ordikhani-Seyedlar & Hasan Eshraghi. (2009) A dysprosium nanowire modified carbon paste electrode for determination of levodopa using fast Fourier transformation square-wave voltammetry method. Colloids and Surfaces B: Biointerfaces 68:1, pages 27-32.
Crossref
Silvana E. Vignaduzzo, Patricia M. Castellano & Teodoro S. Kaufman. (2008) Method development and validation for the simultaneous determination of meloxicam and pridinol mesylate using RP-HPLC and its application in drug formulations. Journal of Pharmaceutical and Biomedical Analysis 46:2, pages 219-225.
Crossref
Abdolkarim Abbaspour & Roya Mirzajani. (2007) Electrochemical monitoring of piroxicam in different pharmaceutical forms with multi-walled carbon nanotubes paste electrode. Journal of Pharmaceutical and Biomedical Analysis 44:1, pages 41-48.
Crossref
Khalil Farhadi & and Ahmad Karimpour. (2007) Electrochemical Determination of Meloxicam in Pharmaceutical Preparation and Biological Fluids Using Oxidized Glassy Carbon Electrodes. Chemical and Pharmaceutical Bulletin 55:4, pages 638-642.
Crossref
Cheng Wang, Zhi Wang, Jun Guan & Xiao Hu. (2006) Voltammetric Determination of Meloxicam in Pharmaceutical Formulation and Human Serum at Glassy Carbon Electrode Modified by Cysteic Acid Formed by Electrochemical Oxidation of L-cysteine. Sensors 6:9, pages 1139-1152.
Crossref
Angel A.J. Torriero, Carlos E. Tonn, Leonides Sereno & Julio Raba. (2006) Electrooxidation mechanism of non-steroidal anti-inflammatory drug piroxicam at glassy carbon electrode. Journal of Electroanalytical Chemistry 588:2, pages 218-225.
Crossref
Elham Anwer Taha, Nahla Nour Salama & Laila El-Sayed Abdel Fattah. (2006) Spectrofluorimetric and Spectrophotometric Stability-Indicating Methods for Determination of Some Oxicams Using 7-Chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). Chemical and Pharmaceutical Bulletin 54:5, pages 653-658.
Crossref
R. Nageswara Rao, S. Meena & A. Raghuram Rao. (2005) An overview of the recent developments in analytical methodologies for determination of COX-2 inhibitors in bulk drugs, pharmaceuticals and biological matrices. Journal of Pharmaceutical and Biomedical Analysis 39:3-4, pages 349-363.
Crossref
Emirhan Nemutlu & Sedef Kir. (2003) Method development and validation for the analysis of meloxicam in tablets by CZE. Journal of Pharmaceutical and Biomedical Analysis 31:2, pages 393-400.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.