364
Views
25
CrossRef citations to date
0
Altmetric
Research Article

Hydrodynamic Flows Around Tablets in Different Pharmacopeial Dissolution Tests

, , , &
Pages 655-662 | Published online: 17 Jun 2002

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Yan Wu, D. O. Kildsig & E. S. Ghaly. (2004) Effect of Hydrodynamic Environment on Tablets Dissolution Rate. Pharmaceutical Development and Technology 9:1, pages 25-37.
Read now

Articles from other publishers (24)

Shotaro Ikuta, Hidetoshi Nakagawa, Toshiya Kai & Kiyohiko Sugano. (2024) Bicarbonate buffer dissolution test with gentle mechanistic stress for bioequivalence prediction of enteric-coated pellet formulations. European Journal of Pharmaceutical Sciences 192, pages 106622.
Crossref
Shotaro Ikuta, Hidetoshi Nakagawa, Toshiya Kai & Kiyohiko Sugano. (2023) Development of bicarbonate buffer flow-through cell dissolution test and its application in prediction of in vivo performance of colon targeting tablets. European Journal of Pharmaceutical Sciences 180, pages 106326.
Crossref
Freja Fredholt, Camilla Di Meo, Stine Sloth, Anette Müllertz & Ragna Berthelsen. (2022) Direct visualizing of paracetamol immediate release tablet disintegration in vivo and in vitro. European Journal of Pharmaceutics and Biopharmaceutics 180, pages 63-70.
Crossref
Hiroyuki Yoshida, Keita Teruya, Yasuhiro Abe, Takayuki Furuishi, Kaori Fukuzawa, Etsuo Yonemochi & Ken-ichi Izutsu. (2021) Altered Media Flow and Tablet Position as Factors of How Air Bubbles Affect Dissolution of Disintegrating and Non-disintegrating Tablets Using a USP 4 Flow-Through Cell Apparatus. AAPS PharmSciTech 22:7.
Crossref
Kaushalendra Chaturvedi, Harsh S. Shah, Rusha Sardhara, Kajal Nahar, Rutesh H. Dave & Kenneth R. Morris. (2021) Protocol development, validation, and troubleshooting of in-situ fiber optic bathless dissolution system (FODS) for a pharmaceutical drug testing. Journal of Pharmaceutical and Biomedical Analysis 195, pages 113833.
Crossref
Hiroyuki Yoshida, Yasuhiro Abe, Naomi Tomita & Ken-ichi Izutsu. (2020) Utilization of Diluted Compendial Media as Dissolution Test Solutions with Low Buffer Capacity for the Investigation of Dissolution Rate of Highly Soluble Immediate Release Drug Products. Chemical and Pharmaceutical Bulletin 68:7, pages 664-670.
Crossref
Andres F. Martinez, Kushal Sinha, Nandkishor Nere, Russell Slade & Steven Castleberry. (2020) Characterization of the Hydrodynamics in the USP Basket Apparatus Using Computational Fluid Dynamics. Journal of Pharmaceutical Sciences 109:3, pages 1231-1241.
Crossref
Vaibhav Rastogi, Pragya Yadav, Niharika Lal, Pallavi Rastogi, B.K. Singh, Navneet Verma & Anurag Verma. (2018) Mathematical prediction of pharmacokinetic parameters-an in-vitro approach for investigating pharmaceutical products for IVIVC. Future Journal of Pharmaceutical Sciences 4:2, pages 175-184.
Crossref
Yoshiko Takeuchi, Rina Usui, Hidekazu Ikezaki, Kohei Tahara & Hirofumi Takeuchi. (2017) Characterization of orally disintegrating films: A feasibility study using an electronic taste sensor and a flow-through cell. Journal of Drug Delivery Science and Technology 39, pages 104-112.
Crossref
Lijie Wang, Kai Chen, Haoyang Wen, Defang Ouyang, Xue Li, Yunyun Gao, Weisan Pan & Xinggang Yang. (2016) Design and Evaluation of Hydrophilic Matrix System Containing Polyethylene Oxides for the Zero-Order Controlled Delivery of Water-Insoluble Drugs. AAPS PharmSciTech 18:1, pages 82-92.
Crossref
Hiroyuki Yoshida, Akemi Kuwana, Hiroko Shibata, Ken-ichi Izutsu & Yukihiro Goda. (2016) Effects of Pump Pulsation on Hydrodynamic Properties and Dissolution Profiles in Flow-Through Dissolution Systems (USP 4). Pharmaceutical Research 33:6, pages 1327-1336.
Crossref
Hiroyuki Yoshida, Akemi Kuwana, Hiroko Shibata, Ken-ichi Izutsu & Yukihiro Goda. (2015) Particle Image Velocimetry Evaluation of Fluid Flow Profiles in USP 4 Flow-Through Dissolution Cells. Pharmaceutical Research 32:9, pages 2950-2959.
Crossref
Jozef Al-Gousous & Peter Langguth. (2015) Oral Solid Dosage Form Disintegration Testing — The Forgotten Test. Journal of Pharmaceutical Sciences 104:9, pages 2664-2675.
Crossref
Asma Radwan, Manfred Wagner, Gordon L. Amidon & Peter Langguth. (2014) Bio-predictive tablet disintegration: Effect of water diffusivity, fluid flow, food composition and test conditions. European Journal of Pharmaceutical Sciences 57, pages 273-279.
Crossref
C. Ferrero & M.R. Jiménez-Castellanos. (2014) In vitro release testing of matrices based on starch–methyl methacrylate copolymers: Effect of tablet crushing force, dissolution medium pH and stirring rate. International Journal of Pharmaceutics 461:1-2, pages 270-279.
Crossref
Anne Seidlitz & Werner Weitschies. (2012) In-vitro dissolution methods for controlled release parenterals and their applicability to drug-eluting stent testing. Journal of Pharmacy and Pharmacology 64:7, pages 969-985.
Crossref
G. Shiko, L.F. Gladden, A.J. Sederman, P.C. Connolly & J.M. Butler. (2011) MRI Studies of the Hydrodynamics in a USP 4 Dissolution Testing Cell. Journal of Pharmaceutical Sciences 100:3, pages 976-991.
Crossref
Emmanuel Scheubel, Marc Lindenberg, Eric Beyssac & Jean-Michel Cardot. (2010) Small Volume Dissolution Testing as a Powerful Method during Pharmaceutical Development. Pharmaceutics 2:4, pages 351-363.
Crossref
Saeed A Qureshi. (2004) Improved drug dissolution and product characterization using a crescent-shaped spindle. Journal of Pharmacy and Pharmacology 56:9, pages 1135-1141.
Crossref
Dave A. Miller, Mirko Gamba, Dorothea Sauer, Troy P. Purvis, Noel T. Clemens & Robert O. WilliamsIIIIII. (2007) Evaluation of the USP dissolution test method A for enteric-coated articles by planar laser-induced fluorescence. International Journal of Pharmaceutics 330:1-2, pages 61-72.
Crossref
Deirdre M. D’Arcy, Owen I. Corrigan & Anne Marie Healy. (2006) Evaluation of hydrodynamics in the basket dissolution apparatus using computational fluid dynamics—Dissolution rate implications. European Journal of Pharmaceutical Sciences 27:2-3, pages 259-267.
Crossref
Saeed A. Qureshi. (2004) Choice of rotation speed (rpm) for bio-relevant drug dissolution testing using a crescent-shaped spindle. European Journal of Pharmaceutical Sciences 23:3, pages 271-275.
Crossref
J Kukura, J.L Baxter & F.J Muzzio. (2004) Shear distribution and variability in the USP Apparatus 2 under turbulent conditions. International Journal of Pharmaceutics 279:1-2, pages 9-17.
Crossref
Brett Kralj & Robert A.W Dryfe. (2003) The rotating paddle cell. Electrochemistry Communications 5:4, pages 325-328.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.