Citations (42)
Keep up to date with the latest research on this topic with citation updates for this article.
Articles from other publishers (42)
Chadakarn Sirasitthichoke, Satish Perivilli, Mark R. Liddell & Piero M. Armenante. (2023) Particle Image Velocimetry (PIV) measurements of USP Apparatus 1 hydrodynamics with 500 mL fill volume. International Journal of Pharmaceutics 647, pages 123492.
Crossref
Crossref
Zongming Gao & Anjanette Smith. (2023) The Effect of Sampling Cannula on In Vitro Dissolution Testing with USP Paddle Method. The AAPS Journal 25:3.
Crossref
Crossref
Alexander M. Kubinski, Gayathri Shivkumar, Reuben A. Georgi, Susan George, James Reynolds, Ricardo D. Sosa & Tzuchi R. Ju. (2023) Predictive Drug Release Modeling Across Dissolution Apparatuses I and II using Computational Fluid Dynamics. Journal of Pharmaceutical Sciences 112:3, pages 808-819.
Crossref
Crossref
Marina Navas-Bachiller, Tim Persoons & Deirdre M. D'Arcy. (2022) Exploring bulk volume, particle size and particle motion definitions to increase the predictive ability of in vitro dissolution simulations. European Journal of Pharmaceutical Sciences 174, pages 106185.
Crossref
Crossref
Satish Perivilli, Steven Walfish, Erika Stippler & Mark R. Liddell. (2022) Impact of Select Geometric and Operational Parameters on Hydrodynamics in Dissolution Apparatus 2 (Paddle Apparatus): A Design of Experiments Analysis Based on Computational Fluid Dynamics Simulations. Pharmaceutical Research 39:5, pages 919-934.
Crossref
Crossref
Chadakarn Sirasitthichoke, Satish Perivilli, Mark R. Liddell & Piero M. Armenante. (2021) Experimental determination of the velocity distribution in USP Apparatus 1 (basket apparatus) using Particle Image Velocimetry (PIV). International Journal of Pharmaceutics: X 3, pages 100078.
Crossref
Crossref
Chadakarn Sirasitthichoke, Sanjaykumar Patel, Kevin G. Reuter, Andre Hermans, Gerard Bredael & Piero M. Armenante. (2021) Influence of basket mesh size on the hydrodynamics in the USP rotating basket dissolution testing Apparatus 1. International Journal of Pharmaceutics 607, pages 120976.
Crossref
Crossref
Alok Ranjan & Prateek K. Jha. (2021) Studying Drug Release through Polymeric Controlled Release Formulations in United States Pharmacopoeia 2 Apparatus Using Multiphysics Simulation and Experiments. Molecular Pharmaceutics 18:7, pages 2600-2611.
Crossref
Crossref
S Hemamanjushree & Vamshi Krishna Tippavajhala. (2020) Simulation of Unit Operations in Formulation Development of Tablets Using Computational Fluid Dynamics. AAPS PharmSciTech 21:3.
Crossref
Crossref
Andres F. Martinez, Kushal Sinha, Nandkishor Nere, Russell Slade & Steven Castleberry. (2020) Characterization of the Hydrodynamics in the USP Basket Apparatus Using Computational Fluid Dynamics. Journal of Pharmaceutical Sciences 109:3, pages 1231-1241.
Crossref
Crossref
Saeed A. Qureshi. 2020. Drug Delivery Trends. Drug Delivery Trends
167
195
.
Yukteshwar Baranwal, Andrés D. Román-Ospino, Golshid Keyvan, Jung Myung Ha, Eon Pyo Hong, Fernando J. Muzzio & Rohit Ramachandran. (2019) Prediction of dissolution profiles by non-destructive NIR spectroscopy in bilayer tablets. International Journal of Pharmaceutics 565, pages 419-436.
Crossref
Crossref
Kristoffer E. Johansson, Jakob Plum, Majid Mosleh, Cecilie M. Madsen, Thomas Rades & Anette Müllertz. (2018) Characterization of the Hydrodynamics in a Miniaturized Dissolution Apparatus. Journal of Pharmaceutical Sciences 107:4, pages 1095-1103.
Crossref
Crossref
Satish Perivilli, Richard Prevost & Erika Stippler. (2017) Velocity Field Visualization in USP Dissolution Apparatus 3 Using Particle Image Velocimetry. Pharmaceutical Research 34:6, pages 1330-1337.
Crossref
Crossref
Y. Chen, Z. Gao & J.Z. Duan. 2017. Developing Solid Oral Dosage Forms. Developing Solid Oral Dosage Forms
355
380
.
Konstantinos Stamatopoulos, Federico Alberini, Hannah Batchelor & Mark J.H. Simmons. (2016) Use of PLIF to assess the mixing performance of small volume USP 2 apparatus in shear thinning media. Chemical Engineering Science 145, pages 1-9.
Crossref
Crossref
Eduardo Hernandez, Pallavi Pawar, Golshid Keyvan, Yifan Wang, Natasha Velez, Gerardo Callegari, Alberto Cuitino, Bozena Michniak-Kohn, Fernando J. Muzzio & Rodolfo J. Romañach. (2016) Prediction of dissolution profiles by non-destructive near infrared spectroscopy in tablets subjected to different levels of strain. Journal of Pharmaceutical and Biomedical Analysis 117, pages 568-576.
Crossref
Crossref
Konstantinos Stamatopoulos, Hannah K. Batchelor, Federico Alberini, John Ramsay & Mark J.H. Simmons. (2015) Understanding the impact of media viscosity on dissolution of a highly water soluble drug within a USP 2 mini vessel dissolution apparatus using an optical planar induced fluorescence (PLIF) method. International Journal of Pharmaceutics 495:1, pages 362-373.
Crossref
Crossref
Hiroyuki Yoshida, Akemi Kuwana, Hiroko Shibata, Ken-ichi Izutsu & Yukihiro Goda. (2015) Particle Image Velocimetry Evaluation of Fluid Flow Profiles in USP 4 Flow-Through Dissolution Cells. Pharmaceutical Research 32:9, pages 2950-2959.
Crossref
Crossref
Leon Shargel & Isadore KanferPradeep Sathe, John Duan & Lawrence Yu. 2013. Generic Drug Product Development. Generic Drug Product Development
183
206
.
Houari Ameur & Mohamed Bouzit. (2013) 3D hydrodynamics and shear rates’ variability in the United States Pharmacopeia Paddle Dissolution Apparatus. International Journal of Pharmaceutics 452:1-2, pages 42-51.
Crossref
Crossref
Yimin Wang & Piero M. Armenante. (2012) A Novel Off-Center Paddle Impeller (OPI) Dissolution Testing System for Reproducible Dissolution Testing of Solid Dosage Forms. Journal of Pharmaceutical Sciences 101:2, pages 746-760.
Crossref
Crossref
Thomas Hörmann, Daniele Suzzi & Johannes G. Khinast. (2011) Mixing and Dissolution Processes of Pharmaceutical Bulk Materials in Stirred Tanks: Experimental and Numerical Investigations. Industrial & Engineering Chemistry Research 50:21, pages 12011-12025.
Crossref
Crossref
Ge Bai, Yimin Wang & Piero M. Armenante. (2011) Velocity profiles and shear strain rate variability in the USP Dissolution Testing Apparatus 2 at different impeller agitation speeds. International Journal of Pharmaceutics 403:1-2, pages 1-14.
Crossref
Crossref
Deanna M. Mudie, Gordon L. Amidon & Gregory E. Amidon. (2010)
Physiological Parameters for Oral Delivery and
in Vitro
Testing
. Molecular Pharmaceutics 7:5, pages 1388-1405.
Crossref
Crossref
Kiyohiko Sugano. (2010) Aqueous Boundary Layers Related to Oral Absorption of a Drug: From Dissolution of a Drug to Carrier Mediated Transport and Intestinal Wall Metabolism. Molecular Pharmaceutics 7:5, pages 1362-1373.
Crossref
Crossref
Ville Rimpiläinen, Marko Kuosmanen, Jarkko Ketolainen, Kristiina Järvinen, Marko Vauhkonen & Lasse M. Heikkinen. (2010) Electrical impedance tomography for three-dimensional drug release monitoring. European Journal of Pharmaceutical Sciences 41:2, pages 407-413.
Crossref
Crossref
Deirdre M. D’Arcy, Bo Liu, Geoff Bradley, Anne Marie Healy & Owen I. Corrigan. (2009) Hydrodynamic and Species Transfer Simulations in the USP 4 Dissolution Apparatus: Considerations for Dissolution in a Low Velocity Pulsing Flow. Pharmaceutical Research 27:2, pages 246-258.
Crossref
Crossref
Maziar Kakhi. (2009) Mathematical modeling of the fluid dynamics in the flow-through cell. International Journal of Pharmaceutics 376:1-2, pages 22-40.
Crossref
Crossref
Ge Bai & Piero M. Armenante. (2009) Hydrodynamic, mass transfer, and dissolution effects induced by tablet location during dissolution testing. Journal of Pharmaceutical Sciences 98:4, pages 1511-1531.
Crossref
Crossref
Michelle Long & Yisheng Chen. 2009. Developing Solid Oral Dosage Forms. Developing Solid Oral Dosage Forms
319
340
.
Jennifer J. Sheng, Paul J. Sirois, Jennifer B. Dressman & Gordon L. Amidon. (2008) Particle diffusional layer thickness in a USP dissolution apparatus II: A combined function of particle size and paddle speed. Journal of Pharmaceutical Sciences 97:11, pages 4815-4829.
Crossref
Crossref
Ge Bai & Piero M. Armenante. (2007) Velocity Distribution and Shear Rate Variability Resulting from Changes in the Impeller Location in the USP Dissolution Testing Apparatus II. Pharmaceutical Research 25:2, pages 320-336.
Crossref
Crossref
G.e. Bai, Piero M. Armenante & Russell V. Plank. (2007) Experimental and computational determination of blend time in USP Dissolution Testing Apparatus II. Journal of Pharmaceutical Sciences 96:11, pages 3072-3086.
Crossref
Crossref
Ge Bai, Piero M. Armenante, Russell V. Plank, Michael Gentzler, Kenneth Ford & Paul Harmon. (2007) Hydrodynamic Investigation of USP Dissolution Test Apparatus II. Journal of Pharmaceutical Sciences 96:9, pages 2327-2349.
Crossref
Crossref
Dave A. Miller, Mirko Gamba, Dorothea Sauer, Troy P. Purvis, Noel T. Clemens & Robert O. WilliamsIIIIII. (2007) Evaluation of the USP dissolution test method A for enteric-coated articles by planar laser-induced fluorescence. International Journal of Pharmaceutics 330:1-2, pages 61-72.
Crossref
Crossref
Shahrzad Missaghi & Reza Fassihi. (2005) Release characterization of dimenhydrinate from an eroding and swelling matrix: selection of appropriate dissolution apparatus. International Journal of Pharmaceutics 293:1-2, pages 35-42.
Crossref
Crossref
Jennifer L. Baxter, Joseph Kukura & Fernando J. Muzzio. (2005) Hydrodynamics-induced variability in the USP apparatus II dissolution test. International Journal of Pharmaceutics 292:1-2, pages 17-28.
Crossref
Crossref
Shrutidevi Agrawal & Ramesh Panchagnula. (2004) Dissolution test as a surrogate for quality evaluation of rifampicin containing fixed dose combination formulations. International Journal of Pharmaceutics 287:1-2, pages 97-112.
Crossref
Crossref
F. Štěpánek. (2004) Computer-Aided Product Design. Chemical Engineering Research and Design 82:11, pages 1458-1466.
Crossref
Crossref
J Kukura, J.L Baxter & F.J Muzzio. (2004) Shear distribution and variability in the USP Apparatus 2 under turbulent conditions. International Journal of Pharmaceutics 279:1-2, pages 9-17.
Crossref
Crossref
Leonard G. McCarthy, Geoff Bradley, James C. Sexton, Owen I. Corrigan & Anne Marie Healy. (2004) Computational fluid dynamics modeling of the paddle dissolution apparatus: Agitation rate, mixing patterns, and fluid velocities. AAPS PharmSciTech 5:2, pages 50-59.
Crossref
Crossref