Publication Cover
Neurological Research
A Journal of Progress in Neurosurgery, Neurology and Neurosciences
Volume 27, 2005 - Issue sup1
59
Views
32
CrossRef citations to date
0
Altmetric
Articles

Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics: flow quantification in elastic sidewall aneurysm models

, , , &
Pages 120-128 | Published online: 19 Jul 2013

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Ahmed Galal, Farhad Bahrassa, John C. Dalfino & Alan S. Boulos. (2013) Stent-assisted treatment of unruptured and ruptured intracranial aneurysms: clinical and angiographic outcome. British Journal of Neurosurgery 27:5, pages 607-616.
Read now

Articles from other publishers (31)

W. Boisseau, T.E. Darsaut, R. Fahed, B. Drake, H. Lesiuk, J.L. Rempel, J.-C. Gentric, J. Ognard, L. Nico, D. Iancu, D. Roy, A. Weill, M. Chagnon, J. Zehr, P. Lavoie, T.N. Nguyen & J. Raymond. (2023) Stent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial. American Journal of Neuroradiology 44:4, pages 381-389.
Crossref
Farouk Mezali, Saida Benmamar, Khatir Naima, Houari Ameur & Ouared Rafik. (2022) Evaluation of stent effect and thrombosis generation with different blood rheology on an intracranial aneurysm by the Lattice Boltzmann method. Computer Methods and Programs in Biomedicine 219, pages 106757.
Crossref
Julien Ognard, Mohamed Abdelrady & Jean-Christophe Gentric. 2022. Endovascular Surgery of Cerebral Aneurysms. Endovascular Surgery of Cerebral Aneurysms 103 138 .
Khalid M Saqr, Sherif Rashad, Simon Tupin, Kuniyasu Niizuma, Tamer Hassan, Teiji Tominaga & Makoto Ohta. (2019) What does computational fluid dynamics tell us about intracranial aneurysms? A meta-analysis and critical review. Journal of Cerebral Blood Flow & Metabolism 40:5, pages 1021-1039.
Crossref
Jong Young Lee, Young Dae Cho, Hyun-Seung Kang & Moon Hee Han. (2020) Healing of Aneurysm after Treatment Using Flow Diverter Stent : Histopathological Study in Experimental Canine Carotid Side Wall Aneurysm. Journal of Korean Neurosurgical Society 63:1, pages 34-44.
Crossref
Chander Sadasivan, Erica Swartwout, Ari D Kappel, Henry H Woo, David J Fiorella & Barry B Lieber. (2018) In vitro measurement of the permeability of endovascular coils deployed in cerebral aneurysms. Journal of NeuroInterventional Surgery 10:9, pages 896-900.
Crossref
Ronak J Dholakia, Ari D Kappel, Andrew Pagano, Henry H Woo, Baruch B Lieber, David J Fiorella & Chander Sadasivan. (2017) In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents. Interventional Neuroradiology 24:2, pages 150-161.
Crossref
M. H. Babiker, Y. Chun, B. Roszelle, W. Hafner, H. Y. Farsani, L. F. Gonzalez, F. Albuquerque, C. Kealey, D. S. Levi, G. P. Carman & D. H. Frakes. (2016) In Vitro Investigation of a New Thin Film Nitinol-Based Neurovascular Flow Diverter. Journal of Medical Devices 10:4.
Crossref
S.V. Frolov, S.V. Sindeev, D. Liepsch & A. Balasso. (2016) Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids. Technology and Health Care 24:3, pages 317-333.
Crossref
Lei Wang, Baochang Shi & Zhenhua Chai. (2016) A lattice Boltzmann study of the asymmetry effect on the hemodynamics in stented fusiform aneurysms. Computers & Mathematics with Applications 71:1, pages 328-348.
Crossref
Y. Shi, G. H. Tang & W. Q. Tao. (2015) Lattice Boltzmann Study of Non-Newtonian Blood Flow in Mother and Daughter Aneurysm and a Novel Stent Treatment. Advances in Applied Mathematics and Mechanics 6:2, pages 165-178.
Crossref
Ajit S. Mallik, Katja Nuss, Peter W. Kronen, Karina Klein, Agnieszka Karol, Brigitte von Rechenberg, Daniel A. Rüfenacht, Isabel Wanke & Zsolt Kulcsár. (2013) A new-generation, low-permeability flow diverting device for treatment of saccular aneurysms. European Radiology 24:1, pages 12-18.
Crossref
Xiao-ning Qiu, Zhi-min Fei, Jue Zhang & Zhao-min Cao. (2013) Influence of high-porosity mesh stent on hemodynamics of intracranial aneurysm: A computational study. Journal of Hydrodynamics 25:6, pages 848-855.
Crossref
Qinghai HuangJinyu XuJiyong ChengShengzhang WangKuizhong WangJian-Min Liu. (2013) Hemodynamic Changes by Flow Diverters in Rabbit Aneurysm Models. Stroke 44:7, pages 1936-1941.
Crossref
Zsolt Kulcsár, Sophia L. Göricke, Elke R. Gizewski, Marc Schlamann, Ulrich Sure, I. Erol Sandalcioglu, Susanne Ladd, Petra Mummel, Oliver Kastrup, Michael Forsting & Isabel Wanke. (2013) Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates. Neuroradiology 55:4, pages 459-465.
Crossref
Changsheng Huang, Zhenhua Chai & Baochang Shi. (2015) Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm. Communications in Computational Physics 13:3, pages 916-928.
Crossref
Chang-Ho Yu, Kaoru Matsumoto, Shuya Shida, Dong Joon Kim & Makoto Ohta. (2012) A steady flow analsys on a cerebral aneurysm model with several stents for new stent design using PIV. Journal of Mechanical Science and Technology 26:5, pages 1333-1340.
Crossref
Woowon Jeong & Kyehan Rhee. (2012) Hemodynamics of Cerebral Aneurysms: Computational Analyses of Aneurysm Progress and Treatment. Computational and Mathematical Methods in Medicine 2012, pages 1-11.
Crossref
Boris Lubicz. (2010) Frontiers of stent-assisted aneurysm coiling. Neuroradiology 53:12, pages 937-938.
Crossref
Youngjae Chun, Soojung Claire Hur, Colin P Kealey, Daniel S Levi, K P Mohanchandra, Dino Di Carlo, Jeff D Eldredge, Fernando Vinuela & Gregory P Carman. (2011) Intra-aneurysmal flow reductions in a thin film nitinol flow diverter. Smart Materials and Structures 20:5, pages 055021.
Crossref
Timothy J. Gundert, Shawn C. Shadden, Andrew R. Williams, Bon-Kwon Koo, Jeffrey A. Feinstein & John F. LaDisaJr.Jr.. (2011) A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models. Annals of Biomedical Engineering 39:5, pages 1423-1437.
Crossref
Yong Hyun Kim, Xiaofeng Xu & Joon Sang Lee. (2010) The Effect of Stent Porosity and Strut Shape on Saccular Aneurysm and its Numerical Analysis with Lattice Boltzmann Method. Annals of Biomedical Engineering 38:7, pages 2274-2292.
Crossref
L. Augsburger, P. Reymond, E. Fonck, Z. Kulcsar, M. Farhat, M. Ohta, N. Stergiopulos & D. A. Rüfenacht. (2009) Methodologies to assess blood flow in cerebral aneurysms: Current state of research and perspectives. Journal of Neuroradiology 36:5, pages 270-277.
Crossref
Sunil Appanaboyina, Fernando Mut, Rainald Löhner, Christopher Putman & Juan Cebral. (2009) Simulation of intracranial aneurysm stenting: Techniques and challenges. Computer Methods in Applied Mechanics and Engineering 198:45-46, pages 3567-3582.
Crossref
Luca Augsburger, Mohamed Farhat, Philippe Reymond, Edouard Fonck, Zsolt Kulcsar, Nikos Stergiopulos & Daniel A. Rüfenacht. (2009) Effect of Flow Diverter Porosity on Intraaneurysmal Blood FlowEffekt der Porosität von „flow diverters“ auf den intraaneurysmatischen Blutfluss. Clinical Neuroradiology 19:3, pages 204-214.
Crossref
Boris Lubicz, Alexandra Bandeira, Michaël Bruneau, Aloys Dewindt, Danielle Balériaux & Olivier De Witte. (2009) Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms. Neuroradiology 51:6, pages 419-425.
Crossref
Christopher S. Eddleman, Michael C. Hurley, Bernard R. Bendok & H. Hunt Batjer. (2009) Cavernous carotid aneurysms: to treat or not to treat?. Neurosurgical Focus 26:5, pages E4.
Crossref
Isabel Wanke & Michael Forsting. (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:12, pages 991-998.
Crossref
S. Appanaboyina, F. Mut, R. Löhner, C. M. Putman & J. R. Cebral. (2008) Computational fluid dynamics of stented intracranial aneurysms using adaptive embedded unstructured grids. International Journal for Numerical Methods in Fluids 57:5, pages 475-493.
Crossref
. (2008) . Journal of the Society of Mechanical Engineers 111:1075, pages 538.
Crossref
Frank Ahlhelm, Christian Roth, Ralf Kaufmann, Gernot Schulte-Altedorneburg, Bernd F. M. Romeike & Wolfgang Reith. (2007) Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device. Neuroradiology 49:12, pages 1023-1028.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.