89
Views
22
CrossRef citations to date
0
Altmetric
Original Research

Goldmann tonometer error correcting prism: clinical evaluation

, , , , , & show all
Pages 835-840 | Published online: 03 May 2017

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Robert Edward T Ang, Neiman Vincent R Bargas, Gladness Henna A Martinez, George Michael N Sosuan & Maria Isabel Nabor-Umali. (2022) Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy. Clinical Ophthalmology 16, pages 1623-1637.
Read now
Mingwu Wang, John Berdahl & Sean McCafferty. (2021) Corneal Crosslinking Biomechanics Evaluated by a Novel and Easily Implemented Differential Tonometry Method. Current Eye Research 46:11, pages 1614-1620.
Read now
Nathan Radcliffe, John Berdahl, Mitchel Ibach, Justin Schweitzer, Jason Levine & Sean McCafferty. (2020) Improved Efficacy of Topical Latanoprost 0.005% Demonstrated by Corneal Biomechanical Correcting Modified Goldmann Prism. Clinical Ophthalmology 14, pages 2245-2253.
Read now
Kevin Gillmann, Giorgio Enrico Bravetti, Laetitia Jessy Niegowski & Kaweh Mansouri. (2019) Using sensors to estimate intraocular pressure: a review of intraocular pressure telemetry in clinical practice. Expert Review of Ophthalmology 14:6, pages 263-276.
Read now
Sean J McCafferty, Eniko T Enikov, Jim Schwiegerling & Sean M Ashley. (2018) Goldmann tonometry tear film error and partial correction with a shaped applanation surface. Clinical Ophthalmology 12, pages 71-78.
Read now

Articles from other publishers (17)

Rémi Yaïci & Gerd Geerling. (2023) Tonometrie: Rückblick und Ausblick (Teil 2). Klinische Monatsblätter für Augenheilkunde.
Crossref
Rémi Yaïci & Gerd Geerling. (2023) Tonometrie: Rückblick und Ausblick (Teil 2). Augenheilkunde up2date 13:01, pages 49-63.
Crossref
Robert Edward T. Ang, Andrew Rixon, Khin Kilgore & Justin Schweitzer. (2022) Goldmann and modified Goldmann tonometry measuring intraocular pressure changes in eyes which underwent myopic laser in situ Keratomileusis and photorefractive keratectomy. BMC Ophthalmology 22:1.
Crossref
Rémi Yaïci & Gerd Geerling. (2022) Tonometrie: Rückblick und Ausblick (Teil 1). Klinische Monatsblätter für Augenheilkunde.
Crossref
Rémi Yaïci & Gerd Geerling. (2022) Tonometrie: Rückblick und Ausblick (Teil 1). Augenheilkunde up2date 12:04, pages 349-365.
Crossref
Kyoung Ohn, Young Ho Noh, Jung Il Moon & Younhea Jung. (2022) Measurement of corneal biomechanical properties in diabetes mellitus using the Corvis ST. Medicine 101:36, pages e30248.
Crossref
Jinping Hu, Jun Liu, Jingting Xia, Jingyu Yan, Zheng Liu & Dan Ma. (2022) The effectiveness of a three-step sterilization method for Goldmann tonometer prism: A cross-sectional study. Indian Journal of Ophthalmology 70:1, pages 138.
Crossref
Kevin Gillmann, Robert Wasilewicz, Kirsten Hoskens, Sonja Simon-Zoula & Kaweh Mansouri. (2021) Continuous 24-hour measurement of intraocular pressure in millimeters of mercury (mmHg) using a novel contact lens sensor: Comparison with pneumatonometry. PLOS ONE 16:3, pages e0248211.
Crossref
Lisa Ramm, Robert Herber, Eberhard Spoerl, Lutz E Pillunat & Naim Terai. (2019) Intraocular pressure measurements in diabetes mellitus. European Journal of Ophthalmology 30:6, pages 1432-1439.
Crossref
Kevin Gillmann, Cara C. Young, Jordan Stanley, Leonard K. Seibold, Kirsten Hoskens, Neha Midha, Malik Y. Kahook & Kaweh Mansouri. (2020) Relationship Between Contact Lens Sensor Output Parameters and Visual Field Progression in Open-angle Glaucoma: Assessment of a Practical Tool to Guide Clinical Risk-assessment. Journal of Glaucoma 29:6, pages 461-466.
Crossref
María Iglesias, Francisco Yebra, Bachar Kudsieh, Andrea Laiseca, Cristina Santos, Jeroni Nadal, Rafael Barraquer & Ricardo P. Casaroli-Marano. (2020) New applanation tonometer for myopic patients after laser refractive surgery. Scientific Reports 10:1.
Crossref
Magdalena Jędzierowska & Robert Koprowski. (2019) Novel dynamic corneal response parameters in a practice use: a critical review. BioMedical Engineering OnLine 18:1.
Crossref
Lisa Ramm, Robert Herber, Eberhard Spoerl, Frederik Raiskup, Lutz E. Pillunat & Naim Terai. (2019) Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST. Journal of Ophthalmology 2019, pages 1-9.
Crossref
Lisa Ramm, Robert Herber, Eberhard Spoerl, Lutz E. Pillunat & Naim Terai. (2019) Measurement of Corneal Biomechanical Properties in Diabetes Mellitus Using the Ocular Response Analyzer and the Corvis ST. Cornea 38:5, pages 595-599.
Crossref
Sean McCafferty, Jason Levine, Jim Schwiegerling & Eniko T. Enikov. (2018) Goldmann and error correcting tonometry prisms compared to intracameral pressure. BMC Ophthalmology 18:1.
Crossref
Sean McCafferty, Kyle Tetrault, Ann McColgin, Warren Chue, Jason Levine & Melissa Muller. (2018) Intraocular Pressure Measurement Accuracy and Repeatability of a Modified Goldmann Prism: Multicenter Randomized Clinical Trial. American Journal of Ophthalmology 196, pages 145-153.
Crossref
Dae Hwan ShinJeong Hun BaeJoon Mo Kim. (2018) The Effect of a Fixed Combination of 0.0015% Tafluprost-0.5% Timolol in Normal Tension Glaucoma Patients. Journal of the Korean Ophthalmological Society 59:8, pages 752.
Crossref