Argus II retinal prosthesis malrotation and repositioning with intraoperative optical coherence tomography in a posterior staphyloma

&
Pages 2213-2216 | Published online: 24 Nov 2015

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (2)

Avni P Finn, Dilraj S Grewal & Lejla Vajzovic. (2018) Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes. Clinical Ophthalmology 12, pages 1089-1097.
Read now
Alexandre Matet, Nawel Amar, Saddek Mohand-Said, José-Alain Sahel & Pierre-Olivier Barale. (2016) Argus II retinal prosthesis implantation with scleral flap and autogenous temporalis fascia as alternative patch graft material: a 4-year follow-up. Clinical Ophthalmology 10, pages 1565-1571.
Read now

Articles from other publishers (13)

Nimra Ghani, Jahnvi Bansal, Abhishek Naidu & Khurram M. Chaudhary. (2023) Long term positional stability of the Argus II retinal prosthesis epiretinal implant. BMC Ophthalmology 23:1.
Crossref
David Avraham & Yitzhak Yitzhaky. (2022) Simulating the perceptual effects of electrode–retina distance in prosthetic vision. Journal of Neural Engineering 19:3, pages 035001.
Crossref
Lucy T Xu, Aleksandra V Rachitskaya, Meghan J DeBenedictis, James Bena, Shannon Morrison & Alex Yuan. (2019) Correlation between Argus II array–retina distance and electrical thresholds of stimulation is improved by measuring the entire array. European Journal of Ophthalmology 31:1, pages 194-203.
Crossref
Abhishek Naidu, Nimra Ghani, Mohammad Saad Yazdanie & Khurram Chaudhary. (2020) Effect of the electrode array-retina gap distance on visual function in patients with the Argus II retinal prosthesis. BMC Ophthalmology 20:1.
Crossref
Stanislao Rizzo, Pierre-Olivier Barale, Sarah Ayello-Scheer, Robert G Devenyi, Marie Noelle Delyfer, Jean-François Korobelnik, Aleksandra Rachitskaya, Alex Yuan, K Thiran Jayasundera, David N Zacks, James T Handa, Sandra R Montezuma, Dara Koozekanani, Paulo Stanga, Lyndon da Cruz, Peter Walter, Albert J Augustin, Lisa C Olmos de Koo, Allen C Ho, Bernd Kirchhof, Paul Hahn, Lejla Vajzovic, Raymond Iezzi, David Gaucher, J Fernando Arevalo, Ninel Z Gregori, Peter Wiedemann, Emin Özmert, Jennifer I Lim, Flavio A Rezende, Suber S Huang, Francesco Merlini, Uday Patel, Robert J Greenberg, Sally Justus, Daniela Bacherini, Laura Cinelli & Mark S Humayun. (2020) Hypotony and the Argus II retinal prosthesis: causes, prevention and management. British Journal of Ophthalmology 104:4, pages 518-523.
Crossref
Lyubomyr M. Lytvynchuk, Christiane I. Falkner-Radler, Andrzej Grzybowski, Carl G. Glittenberg, Farnusch Shams-Mafi, Siamak Ansari-Shahrezaei & Susanne Binder. (2019) Influence of optic media of the human eye on the imaging of Argus® II retinal prosthesis with intraoperative spectral-domain optical coherence tomographyEinfluss der optischen Medien des menschlichen Auges auf die Bildgebung einer Argus®-II-Retinaprothese mit intraoperativer Spectral-Domain optischer Kohärenztomografie. Spektrum der Augenheilkunde 34:1, pages 1-9.
Crossref
Keiko Kataoka & Hiroko Terasaki. 2020. Macular Surgery. Macular Surgery 167 177 .
Ninel Z. Gregori, Natalia F. Callaway, Catherine Hoeppner, Alex Yuan, Aleksandra Rachitskaya, William Feuer, Hossein Ameri, J. Fernando Arevalo, Albert J. Augustin, David G. Birch, Gislin Dagnelie, Salvatore Grisanti, Janet L. Davis, Paul Hahn, James T. Handa, Allen C. Ho, Suber S. Huang, Mark S. Humayun, Raymond IezziJr.Jr., K. Thiran Jayasundera, Gregg T. Kokame, Byron L. Lam, Jennifer I. Lim, Naresh Mandava, Sandra R. Montezuma, Lisa Olmos de Koo, Peter Szurman, Lejla Vajzovic, Peter Wiedemann, James Weiland, Jiong Yan & David N. Zacks. (2018) Retinal Anatomy and Electrode Array Position in Retinitis Pigmentosa Patients After Argus II Implantation: An International Study. American Journal of Ophthalmology 193, pages 87-99.
Crossref
Marie-Noëlle Delyfer, David Gaucher, Marc Govare, Audrey Cougnard-Grégoire, Jean-François Korobelnik, Soufiane Ajana, Saddek Mohand-Saïd, Sarah Ayello-Scheer, Fouzia Rezaiguia-Studer, Hélène Dollfus, José-Alain Sahel & Pierre-Olivier Barale. (2018) Adapted Surgical Procedure for Argus II Retinal Implantation: Feasibility, Safety, Efficiency, and Postoperative Anatomic Findings. Ophthalmology Retina 2:4, pages 276-287.
Crossref
Marianeli Rodriguez, Ninel Z. Gregori, Luiz Roisman, Byron L. Lam & Philip J. Rosenfeld. (2018) Swept-Source OCT Imaging of the Argus II Epiretinal Prosthesis. Ophthalmology Retina 2:4, pages 380-382.
Crossref
Atsuro Uchida, Sunil K. Srivastava & Justis P. Ehlers. (2018) Update on the Intraoperative OCT: Where Do We Stand?. Current Ophthalmology Reports 6:1, pages 24-35.
Crossref
Francesco Parmeggiani, Katia De Nadai, Angela Piovan, Andrea Binotto, Sara Zamengo & Marzio Chizzolini. (2017) Optical Coherence Tomography Imaging in the Management of the Argus II Retinal Prosthesis System. European Journal of Ophthalmology 27:1, pages 16-21.
Crossref
Aleksandra V. Rachitskaya, Alex Yuan, Meghan J. Marino, Jamie Reese & Justis P. Ehlers. (2016) Intraoperative OCT Imaging of the Argus II Retinal Prosthesis System. Ophthalmic Surgery, Lasers and Imaging Retina 47:11, pages 999-1003.
Crossref