137
Views
7
CrossRef citations to date
0
Altmetric
Research Article

Deep brain stimulation lead-contact heating during 3T MRI: single- versus dual-channel pulse generator configurations

, , , , , , & show all
Pages 166-174 | Received 13 Jul 2013, Accepted 28 Aug 2013, Published online: 08 Oct 2013

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Xiaohe Ji, Jianfeng Zheng & Ji Chen. (2017) Numerical evaluation of RF-induced heating for various esophageal stent designs under MRI 1.5 Tesla system. Electromagnetic Biology and Medicine 36:4, pages 379-386.
Read now

Articles from other publishers (6)

Clement T. Chow, Sriranga Kashyap, Aaron Loh, Asma Naheed, Nicole Bennett, Laleh Golestanirad & Alexandre Boutet. 2022. Magnetic Resonance Imaging in Deep Brain Stimulation. Magnetic Resonance Imaging in Deep Brain Stimulation 55 72 .
Maria Kantzanou, Stefanos Korfias, Ioannis Panourias, Damianos E. Sakas & Maria A. Karalexi. (2021) Deep Brain Stimulation-Related Surgical Site Infections: A Systematic Review and Meta-Analysis. Neuromodulation: Technology at the Neural Interface 24:2, pages 197-211.
Crossref
Alexandre Boutet, Clement T. Chow, Keshav Narang, Gavin J. B. Elias, Clemens Neudorfer, Jürgen Germann, Manish Ranjan, Aaron Loh, Alastair J. Martin, Walter Kucharczyk, Christopher J. Steele, Ileana Hancu, Ali R. Rezai & Andres M. Lozano. (2020) Improving Safety of MRI in Patients with Deep Brain Stimulation Devices. Radiology 296:2, pages 250-262.
Crossref
G.P. Thomas & B.C. Jobst. 2017. Innovative Neuromodulation. Innovative Neuromodulation 41 59 .
Hee-Jin Park, Jae Hun Seol, Jeonghun Ku & Sohee Kim. (2016) Computational Study on the Thermal Effects of Implantable Magnetic Stimulation Based on Planar Coils. IEEE Transactions on Biomedical Engineering 63:1, pages 158-167.
Crossref
Lin Shi, An-Chao Yang, Da-Wei Meng, Shao-Wu Li, Huan-Guang Liu, Jun-Ju Li, Xiu Wang, Xin Zhang & Jian-Guo Zhang. (2014) Pathological Alterations and Stress Responses near DBS Electrodes after MRI Scans at 7.0T, 3.0T and 1.5T: An In Vivo Comparative Study. PLoS ONE 9:7, pages e101624.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.