35
Views
16
CrossRef citations to date
0
Altmetric
Original Article

Coulter counter model S and model S-plus measurements of mean erythrocyte volume (MCV) are influenced by the mean erythrocyte haemoglobin concentration (MCHC)

, &
Pages 717-721 | Received 28 Jan 1981, Accepted 26 May 1981, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Marta Stahl & A. Carsten Hansen. (1984) Interference by cold agglutinins with the measurement of particle concentrations in the Coulter Counter® Model S-Plus IV. Scandinavian Journal of Clinical and Laboratory Investigation 44:7, pages 583-586.
Read now

Articles from other publishers (15)

Jo Ann Molnar. 2020. Rodak's Hematology. Rodak's Hematology 174 200 .
K.V. Gilev, E.S. Yastrebova, D.I. Strokotov, M.A. Yurkin, N.A. Karmadonova, A.V. Chernyshev, V.V. Lomivorotov & V.P. Maltsev. (2017) Advanced consumable-free morphological analysis of intact red blood cells by a compact scanning flow cytometer. Cytometry Part A 91:9, pages 867-873.
Crossref
Konstantin V. Gilev, Maxim A. Yurkin, Ekaterina S. Chernyshova, Dmitry I. Strokotov, Andrei V. Chernyshev & Valeri P. Maltsev. (2016) Mature red blood cells: from optical model to inverse light-scattering problem. Biomedical Optics Express 7:4, pages 1305.
Crossref
Benjamin Rappaz, Alexander Barbul, Yves Emery, Rafi Korenstein, Christian Depeursinge, Pierre J. Magistretti & Pierre Marquet. (2008) Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedance volume analyzer. Cytometry Part A 73A:10, pages 895-903.
Crossref
Albert Huisman, Ron Stokwielder & Wouter W. van Solinge. (2004) Mathematical Correction of the In Vitro Storage–Related Increase in Erythrocyte Mean Cell Volume of an Automated Hematology Analyzer—the Cell-Dyn 4000. Laboratory Hematology 10:2, pages 68-73.
Crossref
Young Ran Kim, Ronny van't Oever, Marilou Landayan & James Bearden. (2003) Automated red blood cell differential analysis on a multi‐angle light scatter/fluorescence hematology analyzer. Cytometry Part B: Clinical Cytometry 56B:1, pages 43-54.
Crossref
Corinne Ferrero-Vacher, Karine Maerfeld, Mireille Fraye, Laurence Ollier, Isabelle Sudaka-Sammarcelli, Danièle Nakul-Aquaronne, Frédéric Berthier & Jacques Bayle. (2002) Évaluation du CELL-DYN 4000® Abbott automate d'hématologie. Revue Française des Laboratoires 2002:340, pages 53-64.
Crossref
Ingrid Balga, Max Solenthaler & Miha Furlan. (2000) Should Whole-Body Red Cell Mass Be Measured or Calculated?. Blood Cells, Molecules, and Diseases 26:1, pages 25-31.
Crossref
J. Pastor, R. Cuenca, R. Velarde, I. Marco, L. Vińas & S. Lavin. (1998) Evaluation of a Haematological Analyser (Sysmex F-800) with Equine Blood. Journal of Veterinary Medicine Series A 45:1-10, pages 119-126.
Crossref
Josep Pastor, Rafaela Cuenca, Roser Velarde, Lluis Viñas & Santiago Lavin. (2009) Evaluation of a Hematology Analyzer With Canine and Feline Blood. Veterinary Clinical Pathology 26:3, pages 138-147.
Crossref
R.F. HINCHLIFFE, D. NORCLIFFE, L.M. FARRAR & J.S. LILLEYMAN. (1996) Mean cell haemoglobin concentration in subjects with haemoglobin C, D, E and S traits. Clinical & Laboratory Haematology 18:4, pages 245-248.
Crossref
G.S. PATERAKIS, N.P. LAOUTARIS, S.V. ALEXIA, P.V. SIOUROUNIS, A.K. STAMULAKATOU, E.E. PREMETIS, Ch. SAKELLARIOU, G.N. TERZOGLOU, I.G. PAPASSOTIRIOU & D. LOUKOPOULOS. (2008) The effect of red cell shape on the measurement of red cell volume. A proposed method for the comparative assessment of this effect among various haematology analysers. Clinical & Laboratory Haematology 16:3, pages 235-245.
Crossref
W.N. PATTON, R.J. CAVE & R.I. HARRIS. (2008) A study of changes in red cell volume and haemoglobin concentration during phlebotomy induced iron deficiency and iron repletion using the Technicon H1. Clinical & Laboratory Haematology 13:2, pages 153-161.
Crossref
A J P F Lombarts, A L Koevoet & B Leijnse. (2016) Basic Principles and Problems of Haemocytometry. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 23:4, pages 390-404.
Crossref
D. H. Tycko, M. H. Metz, E. A. Epstein & A. Grinbaum. (1985) Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. Applied Optics 24:9, pages 1355.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.