Validation of photoplethysmography as a method to detect heart rate during rest and exercise

, , &
Pages 264-271 | Received 17 Feb 2015, Accepted 21 Apr 2015, Published online: 26 Jun 2015

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (10)

Morten Pallisgaard Støve & Emil Christian Kjær Hansen. (2022) Accuracy of the Apple Watch Series 6 and the Whoop Band 3.0 for assessing heart rate during resistance exercises. Journal of Sports Sciences 40:23, pages 2639-2644.
Read now
Mansour Ziaei, Alireza Choobineh, Haleh Ghaem & Mohammad Abdoli-Eramaki. (2021) Evaluation of a passive low-back support exoskeleton (Ergo-Vest) for manual waste collection. Ergonomics 64:10, pages 1255-1270.
Read now
Morten P. Støve & Birgit T. Larsen. (2020) Self-monitoring – usability evaluation of heart rate monitoring using wearable devices in patients with acquired brain injury. European Journal of Physiotherapy 22:6, pages 364-372.
Read now
Yanan Zhang, R. Glenn Weaver, Bridget Armstrong, Sarah Burkart, Shuxin Zhang & Michael W. Beets. (2020) Validity of Wrist-Worn photoplethysmography devices to measure heart rate: A systematic review and meta-analysis. Journal of Sports Sciences 38:17, pages 2021-2034.
Read now
Morten Pallisgaard Støve, Rasmus Steengaard Holm, Anne Sofie Kjaersgaard, Kristian Duncker, Mie Ravn Jensen & Birgit Tine Larsen. (2020) Measurement latency significantly contributes to reduced heart rate measurement accuracy in wearable devices. Journal of Medical Engineering & Technology 44:3, pages 125-132.
Read now
Morten Pallisgaard Støve, Emil Haucke, Maria Lysbeck Nymann, Tordur Sigurdsson & Birgit Tine Larsen. (2019) Accuracy of the wearable activity tracker Garmin Forerunner 235 for the assessment of heart rate during rest and activity. Journal of Sports Sciences 37:8, pages 895-901.
Read now
Yang Bai, Paul Hibbing, Constantine Mantis & Gregory J. Welk. (2018) Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR. Journal of Sports Sciences 36:15, pages 1734-1741.
Read now
Nadja Beeler, Lilian Roos, Simon K. Delves, Bertil J. Veenstra, Karl Friedl, Mark J. Buller & Thomas Wyss. (2018) The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers. IISE Transactions on Occupational Ergonomics and Human Factors 6:1, pages 1-10.
Read now
Alexander H. K. Montoye, Joe R. Mitrzyk & Monroe J. Molesky. (2017) Comparative Accuracy of a Wrist-Worn Activity Tracker and a Smart Shirt for Physical Activity Assessment. Measurement in Physical Education and Exercise Science 21:4, pages 201-211.
Read now
Zhen Wang & Shan Fu. (2016) Evaluation of a strapless heart rate monitor during simulated flight tasks. Journal of Occupational and Environmental Hygiene 13:3, pages 185-192.
Read now

Articles from other publishers (84)

Óscar López‐Belmonte, Adrián Febles‐Castro, Ana Gay, Francisco Cuenca‐Fernández, Raúl Arellano & Jesús J. Ruiz‐Navarro. (2023) Validity of the polar verity sense during swimming at different locations and intensities. Scandinavian Journal of Medicine & Science in Sports 33:12, pages 2623-2625.
Crossref
Daniel Koerber, Shawn Khan, Tahmina Shamsheri, Abirami Kirubarajan & Sangeeta Mehta. (2022) Accuracy of Heart Rate Measurement with Wrist-Worn Wearable Devices in Various Skin Tones: a Systematic Review. Journal of Racial and Ethnic Health Disparities 10:6, pages 2676-2684.
Crossref
James W. Navalta, Dustin W. Davis, Elias M. Malek, Bryson Carrier, Nathaniel G. Bodell, Jacob W. Manning, Jeffrey Cowley, Merrill Funk, Marcus M. Lawrence & Mark DeBeliso. (2023) Heart rate processing algorithms and exercise duration on reliability and validity decisions in biceps-worn Polar Verity Sense and OH1 wearables. Scientific Reports 13:1.
Crossref
Filippo Scalise, Ferruccio Cavanna, Chiara Godio & Egidio P. Beretta. (2023) Exercise Intensity and Activity Energy Expenditure of Professional Golf Players in Official Competitive Setting. Sports Health: A Multidisciplinary Approach, pages 194173812311751.
Crossref
V. Devaki, Madan Kumar Lakshmanan & T. Jayanthi. (2023) On the Development of a Wearable Multi-Spectral Photoplethysmographic Device for Heart Rate Detection. On the Development of a Wearable Multi-Spectral Photoplethysmographic Device for Heart Rate Detection.
Rafael Silva, Gonçalo Salvador, Patrícia Bota, Ana Fred & Hugo Plácido da Silva. (2022) Impact of sampling rate and interpolation on photoplethysmography and electrodermal activity signals’ waveform morphology and feature extraction. Neural Computing and Applications 35:8, pages 5661-5677.
Crossref
Pilar Martín-Escudero, Ana María Cabanas, María Luisa Dotor-Castilla, Mercedes Galindo-Canales, Francisco Miguel-Tobal, Cristina Fernández-Pérez, Manuel Fuentes-Ferrer & Romano Giannetti. (2023) Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?. Bioengineering 10:2, pages 254.
Crossref
Jie Han, Weihua Ou, Jiahao Xiong & Shihua Feng. (2022) Remote Heart Rate Estimation by Pulse Signal Reconstruction Based on Structural Sparse Representation. Electronics 11:22, pages 3738.
Crossref
Carla Alfonso, Miguel A. Garcia-Gonzalez, Eva Parrado, Jessyca Gil-Rojas, Juan Ramos-Castro & Lluis Capdevila. (2022) Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology. Scientific Reports 12:1.
Crossref
Ren-Jay Shei, Ian G. Holder, Alicia S. Oumsang, Brittni A. Paris & Hunter L. Paris. (2022) Wearable activity trackers–advanced technology or advanced marketing?. European Journal of Applied Physiology 122:9, pages 1975-1990.
Crossref
Mario Mekhael, Chan Ho Lim, Abdel Hadi El Hajjar, Charbel Noujaim, Christopher Pottle, Noor Makan, Lilas Dagher, Yichi Zhang, Nour Chouman, Dan L Li, Tarek Ayoub & Nassir Marrouche. (2022) Studying the Effect of Long COVID-19 Infection on Sleep Quality Using Wearable Health Devices: Observational Study. Journal of Medical Internet Research 24:7, pages e38000.
Crossref
Craig J. GoergenMacKenzie J. Tweardy, Steven R. Steinhubl, Stephan W. Wegerich, Karnika Singh, Rebecca J. Mieloszyk & Jessilyn Dunn. (2022) Detection and Monitoring of Viral Infections via Wearable Devices and Biometric Data. Annual Review of Biomedical Engineering 24:1, pages 1-27.
Crossref
Pamela Song. (2022) Can Fitness Trackers Track Sleep?. Journal of Sleep Medicine 19:1, pages 1-5.
Crossref
Oğulhan KAYABAŞ, Mutlu CUĞ & Cemalettin BUDAK. (2022) FOTOPLETİSMOGRAFİ TEKNOLOJİSİNE DAYALI KALP ATIM HIZI ÖLÇÜMÜ YAPAN GİYİLEBİLİR AKILLI SAATLERİN KARŞILAŞTIRMALI DEĞERLENDİRİLMESİ: HUAWEI HONOR BAND 5 VS XIAOMI MI SMART BAND 5. Ankara Üniversitesi Beden Eğitimi ve Spor Yüksekokulu SPORMETRE Beden Eğitimi ve Spor Bilimleri Dergisi, pages 106-118.
Crossref
Alexander Bigazzi, Fajar Ausri, Luke Peddie, Dillon Fitch & Eli Puterman. (2022) Physiological markers of traffic-related stress during active travel. Transportation Research Part F: Traffic Psychology and Behaviour 84, pages 223-238.
Crossref
Xinxia Li, Chenghong Hu, Airong Meng, Yanmei Guo, Yang Chen & Rongqing Dang. (2022) Heart rate variability and heart rate monitoring of nurses using PPG and ECG signals during working condition: A pilot study . Health Science Reports 5:1.
Crossref
Eveline Mestrom, Ruben Deneer, Alberto G Bonomi, Jenny Margarito, Jos Gelissen, Reinder Haakma, Hendrikus H M Korsten, Volkher Scharnhorst & R Arthur Bouwman. (2021) Validation of Heart Rate Extracted From Wrist-Based Photoplethysmography in the Perioperative Setting: Prospective Observational Study. JMIR Cardio 5:2, pages e27765.
Crossref
Wiesław Szaj, Wiktoria Wojnarowska & Bogdan Pajdo. (2021) First Evaluation of the PTN-104 Plethysmographic Sensor for Heart Rate Measurement. Measurement Science Review 21:5, pages 117-122.
Crossref
Ömer Muhsin DÜNDAR & Ahmet AYDIN. (2021) SPORCULARIN KALP ATIM HIZININ ESP-NOW KULLANILARAK KABLOSUZ İLETİMİHeart Rate in Athletes and Wireless Transmission Using ESP-NOW. Konya Journal of Engineering Sciences 9:3, pages 633-646.
Crossref
Matthew R. Lujan, Ignacio Perez-Pozuelo & Michael A. Grandner. (2021) Past, Present, and Future of Multisensory Wearable Technology to Monitor Sleep and Circadian Rhythms. Frontiers in Digital Health 3.
Crossref
Brian C. RiderScott A. Conger, Grace L. DitzenbergerSummer S. BestemanClaire M. BouretAdam M. Coughlin. (2021) Examining the Accuracy of the Polar A360 Monitor. Journal of Strength and Conditioning Research 35:8, pages 2165-2169.
Crossref
Jan M Mühlen, Julie Stang, Esben Lykke Skovgaard, Pedro B Judice, Pablo Molina-Garcia, William Johnston, Luís B Sardinha, Francisco B Ortega, Brian Caulfield, Wilhelm Bloch, Sulin Cheng, Ulf Ekelund, Jan Christian Brønd, Anders Grøntved & Moritz Schumann. (2021) Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network. British Journal of Sports Medicine 55:14, pages 767-779.
Crossref
Szabolcs Béres & László Hejjel. (2021) The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers. Biomedical Signal Processing and Control 68, pages 102589.
Crossref
David Joseph Muggeridge, Kirsty Hickson, Aimie Victoria Davies, Oonagh M Giggins, Ian L Megson, Trish Gorely & Daniel R Crabtree. (2021) Measurement of Heart Rate Using the Polar OH1 and Fitbit Charge 3 Wearable Devices in Healthy Adults During Light, Moderate, Vigorous, and Sprint-Based Exercise: Validation Study. JMIR mHealth and uHealth 9:3, pages e25313.
Crossref
Ishita Ray, Daniyal Liaqat, Moshe Gabel & Eyal de Lara. (2021) Skin tone, Confidence, and Data Quality of Heart Rate Sensing in WearOS Smartwatches. Skin tone, Confidence, and Data Quality of Heart Rate Sensing in WearOS Smartwatches.
Jane A. Leopold, Roger B. Davis & Elliott M. Antman. (2021) Data from Digital Health Devices Informs Ideal Cardiovascular Health. Journal of Personalized Medicine 11:3, pages 189.
Crossref
Nur Intan Fathehah Mohd Lahil, Farrah Wong, Ali Chekima, Sariah Abang, Normah Awang Besar, Aroland Jilui Kiring, Yew Hoe Tung, Chung Seng Kheau & Jamal Ahmad Dargham. (2021) Non-Invasive Blood Pressure and Heart Rate Sensing Using Photoplethysmogram Sensor. Non-Invasive Blood Pressure and Heart Rate Sensing Using Photoplethysmogram Sensor.
Tricia Shumate, Magdalen Link, James Furness, Kevin Kemp-Smith, Vini Simas & Mike Climstein. (2021) Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities. PeerJ 9, pages e10893.
Crossref
Andrew R. JAGIM, Nicolas KOCH-GALLUP, Clayton L. CAMIC, Leah KROENING, Charles NOLTE, Cassidy SCHROEDER, Lindsay GRAN & Jacob L. ERICKSON. (2021) The accuracy of fitness watches for the measurement of heart rate and energy expenditure during moderate intensity exercise. The Journal of Sports Medicine and Physical Fitness 61:2.
Crossref
Masaki Kobayashi, Tomoyuki Shinohara & Shigeru Usuda. (2021) Accuracy of wrist-worn heart rate monitors during physical therapy sessions among hemiparetic inpatients with stroke. Journal of Physical Therapy Science 33:1, pages 45-51.
Crossref
Valeria Villani, Massimiliano Righi, Lorenzo Sabattini & Cristian Secchi. (2020) Wearable Devices for the Assessment of Cognitive Effort for Human–Robot Interaction. IEEE Sensors Journal 20:21, pages 13047-13056.
Crossref
Antti Puranen, Tuomas Halkola, Ole Kirkeby & Antti Vehkaoja. (2020) Effect of skin tone and activity on the performance of wrist-worn optical beat-to-beat heart rate monitoring. Effect of skin tone and activity on the performance of wrist-worn optical beat-to-beat heart rate monitoring.
James W. Navalta, Jeffrey Montes, Nathaniel G. Bodell, Robert W. Salatto, Jacob W. Manning & Mark DeBeliso. (2020) Concurrent heart rate validity of wearable technology devices during trail running. PLOS ONE 15:8, pages e0238569.
Crossref
Bernard Fong, A.C.M. Fong & C.K. Li. 2020. Telemedicine Technologies. Telemedicine Technologies 71 113 .
Tanut Choksatchawathi, Puntawat Ponglertnapakorn, Apiwat Ditthapron, Pitshaporn Leelaarporn, Thayakorn Wisutthisen, Maytus Piriyajitakonkij & Theerawit Wilaiprasitporn. (2020) Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach. IEEE Sensors Journal 20:13, pages 7433-7446.
Crossref
Gloria Cosoli, Susanna Spinsante & Lorenzo Scalise. (2020) Wrist-worn and chest-strap wearable devices: Systematic review on accuracy and metrological characteristics. Measurement 159, pages 107789.
Crossref
Benjamin W. Nelson, Carissa A. Low, Nicholas Jacobson, Patricia Areán, John Torous & Nicholas B. Allen. (2020) Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research. npj Digital Medicine 3:1.
Crossref
Hsueh-Wen Chow & Chao-Ching Yang. (2020) Accuracy of Optical Heart Rate Sensing Technology in Wearable Fitness Trackers for Young and Older Adults: Validation and Comparison Study. JMIR mHealth and uHealth 8:4, pages e14707.
Crossref
Bjørn Harald Olstad & Christoph Zinner. (2020) Validation of the Polar OH1 and M600 optical heart rate sensors during front crawl swim training. PLOS ONE 15:4, pages e0231522.
Crossref
Qinghua He & Ruikang Wang. (2020) Hyperspectral imaging enabled by an unmodified smartphone for analyzing skin morphological features and monitoring hemodynamics. Biomedical Optics Express 11:2, pages 895.
Crossref
Piyush Sharma, Syed Anas Imtiaz & Esther Rodriguez-Villegas. (2019) Acoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist. Scientific Reports 9:1.
Crossref
Olivia Walch, Yitong Huang, Daniel Forger & Cathy Goldstein. (2019) Sleep stage prediction with raw acceleration and photoplethysmography heart rate data derived from a consumer wearable device. Sleep 42:12.
Crossref
Cyrille Herkert, Jos Johannes Kraal, Eline Maria Agnes van Loon, Martijn van Hooff & Hareld Marijn Clemens Kemps. (2019) Usefulness of Modern Activity Trackers for Monitoring Exercise Behavior in Chronic Cardiac Patients: Validation Study. JMIR mHealth and uHealth 7:12, pages e15045.
Crossref
Mario Budig, Volker Höltke & Michael Keiner. (2019) Accuracy of optical heart rate measurement and distance measurement of a fitness tracker and their consequential use in sportsDie Genauigkeit der optischen Herzfrequenz- und Entfernungsmessung eines Fitness-Trackers und die daraus folgende Nutzung im sportlichen Training. German Journal of Exercise and Sport Research 49:4, pages 402-409.
Crossref
Andre Matthias Müller, Nan Xin Wang, Jiali Yao, Chuen Seng Tan, Ivan Cherh Chiet Low, Nicole Lim, Jeremy Tan, Agnes Tan & Falk Müller-Riemenschneider. (2019) Heart Rate Measures From Wrist-Worn Activity Trackers in a Laboratory and Free-Living Setting: Validation Study. JMIR mHealth and uHealth 7:10, pages e14120.
Crossref
Szabolcs Béres, Lőrinc Holczer & László Hejjel. (2019) On the Minimal Adequate Sampling Frequency of the Photoplethysmogram for Pulse Rate Monitoring and Heart Rate Variability Analysis in Mobile and Wearable Technology. Measurement Science Review 19:5, pages 232-240.
Crossref
Andrew G. Siddall, Steven D. Powell, Sarah C. Needham‐Beck, Victoria C. Edwards, Jane E.S. Thompson, Sarah S. Kefyalew, Priya A. Singh, Elise R. Orford, Michelle C. Venables, Sarah Jackson, Julie P. Greeves, Sam D. Blacker & Steve D. Myers. (2019) Validity of energy expenditure estimation methods during 10 days of military training. Scandinavian Journal of Medicine & Science in Sports 29:9, pages 1313-1321.
Crossref
Passler, Müller & Senner. (2019) In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?. Sensors 19:17, pages 3641.
Crossref
Khasnur Abd Malek, Mazapuspavina Md-Yasin, Ilham Ameera Ismail, Zahirah Tharek, Nik Munirah Nik Mohd Nasir, Hashbullah Ismail, Hock Chuan Lim, Mohamed Fareq Malek & Nahar Azmi Mohamed. (2019) Exercise Intensity in Exergaming: An approach by GameFiTT. Exercise Intensity in Exergaming: An approach by GameFiTT.
Borja Sañudo, Moisés De Hoyo, Alejandro Muñoz-López, John Perry & Grant Abt. (2019) Pilot Study Assessing the Influence of Skin Type on the Heart Rate Measurements Obtained by Photoplethysmography with the Apple Watch. Journal of Medical Systems 43:7.
Crossref
Imali T. Hettiarachchi, Samer Hanoun, Darius Nahavandi & Saeid Nahavandi. (2019) Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities. PLOS ONE 14:5, pages e0217288.
Crossref
Tim Collins, Sandra I. Woolley, Salome Oniani, Ivan Miguel Pires, Nuno M. Garcia, Sean J. Ledger & Anand Pandyan. (2019) Version Reporting and Assessment Approaches for New and Updated Activity and Heart Rate Monitors. Sensors 19:7, pages 1705.
Crossref
Benjamin W Nelson & Nicholas B Allen. (2019) Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study. JMIR mHealth and uHealth 7:3, pages e10828.
Crossref
Yong-Yan Fan, Yan-Guang Li, Jian Li, Wen-Kun Cheng, Zhao-Liang Shan, Yu-Tang Wang & Yu-Tao Guo. (2019) Diagnostic Performance of a Smart Device With Photoplethysmography Technology for Atrial Fibrillation Detection: Pilot Study (Pre-mAFA II Registry). JMIR mHealth and uHealth 7:3, pages e11437.
Crossref
Jongmin Hwang, Jun Kim, Kee-Joon Choi, Min Soo Cho, Gi-Byoung Nam & You-Ho Kim. (2019) Assessing Accuracy of Wrist-Worn Wearable Devices in Measurement of Paroxysmal Supraventricular Tachycardia Heart Rate. Korean Circulation Journal 49:5, pages 437.
Crossref
Ravi Kondama Reddy, Rubin Pooni, Dessi P Zaharieva, Brian Senf, Joseph El Youssef, Eyal Dassau, Francis J Doyle III, Mark A Clements, Michael R Rickels, Susana R Patton, Jessica R Castle, Michael C Riddell & Peter G Jacobs. (2018) Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study. JMIR mHealth and uHealth 6:12, pages e10338.
Crossref
Francesco Sartor, Jos Gelissen, Ralph van Dinther, David Roovers, Gabriele B. Papini & Giuseppe Coppola. (2018) Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients. BMC Sports Science, Medicine and Rehabilitation 10:1.
Crossref
Joseph M. Stock, Ryan T. Pohlig, Matthew J. Botieri, David G. Edwards & Gregory M. Dominick. (2018) Heart Rate Equivalency of the Fitbit Charge HR During Continuous Aerobic Exercise. Journal for the Measurement of Physical Behaviour 1:3, pages 122-129.
Crossref
Yonggu Lee, Jun-Young Park, Yeon-Woo Choi, Hyun-Kyung Park, Seok-Hyun Cho, Sung Ho Cho & Young-Hyo Lim. (2018) A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology. Scientific Reports 8:1.
Crossref
Francesco Sartor, Gabriele Papini, Lieke Gertruda Elisabeth Cox & John Cleland. (2018) Methodological Shortcomings of Wrist-Worn Heart Rate Monitors Validations. Journal of Medical Internet Research 20:7, pages e10108.
Crossref
Orlando S. Hoilett, Ashlyn M. Twibell, Rohit Srivastava & Jacqueline C. Linnes. (2018) Kick LL: A Smartwatch for Monitoring Respiration and Heart Rate using Photoplethysmography. Kick LL: A Smartwatch for Monitoring Respiration and Heart Rate using Photoplethysmography.
Lorenzo Scalise & Gloria Cosoli. (2018) Wearables for health and fitness: Measurement characteristics and accuracy. Wearables for health and fitness: Measurement characteristics and accuracy.
Peter Düking, Franz Konstantin Fuss, Hans-Christer Holmberg & Billy Sperlich. (2018) Recommendations for Assessment of the Reliability, Sensitivity, and Validity of Data Provided by Wearable Sensors Designed for Monitoring Physical Activity. JMIR mHealth and uHealth 6:4, pages e102.
Crossref
Katrin Hänsel, Romina Poguntke, Hamed Haddadi, Akram Alomainy & Albrecht Schmidt. (2018) What to Put on the User. What to Put on the User.
André Henriksen, Martin Haugen Mikalsen, Ashenafi Zebene Woldaregay, Miroslav Muzny, Gunnar Hartvigsen, Laila Arnesdatter Hopstock & Sameline Grimsgaard. (2018) Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables. Journal of Medical Internet Research 20:3, pages e110.
Crossref
Gloria Pelizzo, Anna Guddo, Aurora Puglisi, Annalisa De Silvestri, Calogero Comparato, Mario Valenza, Emanuele Bordonaro & Valeria Calcaterra. (2018) Accuracy of a Wrist-Worn Heart Rate Sensing Device during Elective Pediatric Surgical Procedures. Children 5:3, pages 38.
Crossref
Johannes Schneider, Marc Schroth, Jorg Ottenbacher & Wilhelm Stork. (2018) A novel wearable sensor device for continuous monitoring of cardiac activity during sleep. A novel wearable sensor device for continuous monitoring of cardiac activity during sleep.
Simone Benedetto, Christian Caldato, Elia Bazzan, Darren C. Greenwood, Virginia Pensabene & Paolo Actis. (2018) Assessment of the Fitbit Charge 2 for monitoring heart rate. PLOS ONE 13:2, pages e0192691.
Crossref
Harishchandra Dubey, Ramdas Kumaresan & Kunal Mankodiya. (2016) Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts. Journal of Ambient Intelligence and Humanized Computing 9:1, pages 137-150.
Crossref
Julia Pietilä, Saeed Mehrang, Johanna Tolonen, Elina Helander, Holly Jimison, Misha Pavel & Ilkka Korhonen. 2018. EMBEC & NBC 2017. EMBEC & NBC 2017 145 148 .
JOHN F. HORTON, PRO STERGIOU, TAK S. FUNG & LARRY KATZ. (2017) Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise. Medicine & Science in Sports & Exercise 49:12, pages 2600-2607.
Crossref
Jason Nogic, Paul Min Thein, James Cameron, Sam Mirzaee, Abdul Ihdayhid & Arthur Nasis. (2017) The utility of personal activity trackers (Fitbit Charge 2) on exercise capacity in patients post acute coronary syndrome [UP-STEP ACS Trial]: a randomised controlled trial protocol. BMC Cardiovascular Disorders 17:1.
Crossref
Junichirou Ishio & Naoya Abe. (2017) Measuring Affective Well-Being by the Combination of the Day Reconstruction Method and a Wearable Device: Case Study of an Aging and Depopulating Community in Japan. Augmented Human Research 2:1.
Crossref
Jorge L. Storniolo, Gaspare Pavei & Alberto E. Minetti. (2017) A “Wearable” Test for Maximum Aerobic Power: Real-Time Analysis of a 60-m Sprint Performance and Heart Rate Off-Kinetics. Frontiers in Physiology 8.
Crossref
Alexander Wilhelm Gorny, Seaw Jia Liew, Chuen Seng Tan & Falk Müller-Riemenschneider. (2017) Fitbit Charge HR Wireless Heart Rate Monitor: Validation Study Conducted Under Free-Living Conditions. JMIR mHealth and uHealth 5:10, pages e157.
Crossref
Jakub Parak, Maria Uuskoski, Jan Machek & Ilkka Korhonen. (2017) Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running. JMIR mHealth and uHealth 5:7, pages e97.
Crossref
Pedro Fonseca, Tim Weysen, Maaike S. Goelema, Els I.S. Møst, Mustafa Radha, Charlotte Lunsingh Scheurleer, Leonie van den Heuvel & Ronald M. Aarts. (2017) Validation of Photoplethysmography-Based Sleep Staging Compared With Polysomnography in Healthy Middle-Aged Adults. Sleep 40:7.
Crossref
Alexander J. Casson, Rachel Saunders & John C. Batchelor. (2017) Five Day Attachment ECG Electrodes for Longitudinal Bio-Sensing Using Conformal Tattoo Substrates. IEEE Sensors Journal 17:7, pages 2205-2214.
Crossref
Erin E Dooley, Natalie M Golaszewski & John B Bartholomew. (2017) Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices. JMIR mHealth and uHealth 5:3, pages e34.
Crossref
Jos Hendrikx, Loes S Ruijs, Lieke GE Cox, Paul MC Lemmens, Erik GP Schuijers & Annelies HC Goris. (2017) Clinical Evaluation of the Measurement Performance of the Philips Health Watch: A Within-Person Comparative Study. JMIR mHealth and uHealth 5:2, pages e10.
Crossref
Jens Muehlsteff, Erik Bresch, Lars Schmitt, Jos Gelissen & Peter Bingley. (2016) Comparison of pulse wave velocity derived from accelerometer and reflective photo-plethysmography signals placed at the carotid and femoral artery. Comparison of pulse wave velocity derived from accelerometer and reflective photo-plethysmography signals placed at the carotid and femoral artery.
Matthew P. Wallen, Sjaan R. Gomersall, Shelley E. Keating, Ulrik Wisløff & Jeff S. Coombes. (2016) Accuracy of Heart Rate Watches: Implications for Weight Management. PLOS ONE 11:5, pages e0154420.
Crossref
Sarah E Stahl, Hyun-Sung An, Danae M Dinkel, John M Noble & Jung-Min Lee. (2016) How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?. BMJ Open Sport & Exercise Medicine 2:1, pages e000106.
Crossref
Peter Düking, Andreas Hotho, Hans-Christer Holmberg, Franz Konstantin Fuss & Billy Sperlich. (2016) Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies. Frontiers in Physiology 7.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.