Imaging with electricity: Report of the European Concerted Action on Impedance Tomography

, &
Pages 201-232 | Published online: 09 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (2)

LiXu Liu, WeiWei Dong, XunMing Ji, LiHua Chen, Ling Chen, Wei He & JianPing Jia. (2006) A new method of noninvasive brain-edema monitoring in stroke: cerebral electrical impedance measurement. Neurological Research 28:1, pages 31-37.
Read now

Articles from other publishers (145)

Junnan Gu, Shenghe Deng, Zhenxing Jiang, Fuwei Mao, Yifan Xue, Le Qin, Jianguo Shi, Jia Yang, Huili Li, Jie Yu, Ke Liu, Ke Wu, Yinghao Cao & Kailin Cai. (2023) Modified Naples prognostic score for evaluating the prognosis of patients with obstructive colorectal cancer. BMC Cancer 23:1.
Crossref
Mi Wang. 2022. Industrial Tomography. Industrial Tomography 31 76 .
Jan Porzuczek. (2021) Multifrequency Impedance Tomography System for Research on Environmental and Thermal Processes. Energies 14:19, pages 6366.
Crossref
Chao Zhang, Meng Dai, Wei Liu, Xiaohui Bai, Jiaming Wu, Canhua Xu, Junying Xia, Feng Fu, Xuetao Shi, Xiuzhen Dong, Faguang Jin & Fusheng You. (2018) Global and regional degree of obstruction determined by electrical impedance tomography in patients with obstructive ventilatory defect. PLOS ONE 13:12, pages e0209473.
Crossref
Vimal Mothi, Yeong Shiong Chiew & Chee Pin Tan. (2018) Development of Electrical Impedance Tomography for Breast Phantom Monitoring. Development of Electrical Impedance Tomography for Breast Phantom Monitoring.
Xuetao Shi, Weichen Li, Fusheng You, Xuyang Huo, Canhua Xu, Zhenyu Ji, Ruigang Liu, Benyuan Liu, Yandong Li, Feng Fu & Xiuzhen Dong. (2018) High-Precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging. IEEE Sensors Journal, pages 1-1.
Crossref
Tohru F. Yamaguchi & Yoshiwo Okamoto. (2018) Computational method for estimating boundary of abdominal subcutaneous fat for absolute electrical impedance tomography. International Journal for Numerical Methods in Biomedical Engineering 34:1, pages e2909.
Crossref
Tobias Menden, Jakob Orschulik, Toni Tholen, Steffen Leonhardt & Marian Walter. (2017) Approach to compensate measurement errors in electrical impedance tomography. Approach to compensate measurement errors in electrical impedance tomography.
B H Brown, R H Smallwood, D C Barber, P V Lawford & D R HoseB H Brown. 2017. Medical Physics and Biomedical Engineering. Medical Physics and Biomedical Engineering 344 398 .
Stefano Mandija, Astrid L.H.M.W. van Lier, Ulrich Katscher, Petar I. Petrov, Sebastian F.W. Neggers, Peter R. Luijten & Cornelis A.T. van den Berg. (2016) A geometrical shift results in erroneous appearance of low frequency tissue eddy current induced phase maps. Magnetic Resonance in Medicine 76:3, pages 905-912.
Crossref
Mi Wang, Qiang Wang & Bishal Karki. (2016) Arts of electrical impedance tomographic sensing. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences 374:2070, pages 20150329.
Crossref
Yan Fu, Chao Tan & Feng Dong. (2016) Analysis of response for magnetic induction tomography with internal source. Measurement 78, pages 260-277.
Crossref
Olaf DösselOlaf Dössel. 2016. Bildgebende Verfahren in der Medizin. Bildgebende Verfahren in der Medizin 399 418 .
Arie Meir & Boris Rubinsky. (2015) Electrical Impedance Tomography of Electrolysis. PLOS ONE 10:6, pages e0126332.
Crossref
M. Wang. 2015. Industrial Tomography. Industrial Tomography 23 59 .
Peter A. Dargaville, Inéz Frerichs & David Tingay. 2015. Pediatric and Neonatal Mechanical Ventilation. Pediatric and Neonatal Mechanical Ventilation 441 471 .
Norhayati Mohd Zain & Kanaga Kumari Chelliah. (2014) Breast Imaging Using Electrical Impedance Tomography: Correlation of Quantitative Assessment with Visual Interpretation. Asian Pacific Journal of Cancer Prevention 15:3, pages 1327-1331.
Crossref
B. Brown. 2014. Comprehensive Biomedical Physics. Comprehensive Biomedical Physics 73 90 .
Tohru F. Yamaguchi, Mitsuhiro Katashima, Li-qun Wang & Shinya Kuriki. (2013) Imaging and estimation of human abdominal fat by electrical impedance tomography using multiple voltage measurement patterns. Imaging and estimation of human abdominal fat by electrical impedance tomography using multiple voltage measurement patterns.
Jin Keun Seo & Eung Je Woo. 2013. Nonlinear Inverse Problems in Imaging. Nonlinear Inverse Problems in Imaging 251 294 .
Jin Keun Seo & Eung Je Woo. 2013. Nonlinear Inverse Problems in Imaging. Nonlinear Inverse Problems in Imaging 195 249 .
Carmel Mothersill, Richard Smith, Matthew Henry, Colin Seymour & Raimond Wong. (2012) Alternative Medicine Techniques Have Non-Linear Effects on Radiation Response and Can Alter the Expression of Radiation Induced Bystander Effects. Dose-Response 11:1, pages dose-response.1.
Crossref
Barbara VogtSven PulletzGunnar ElkeZhanqi Zhao, Peter Zabel, Norbert WeilerInéz Frerichs. (2012) Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing. Journal of Applied Physiology 113:7, pages 1154-1161.
Crossref
Marc Bodenstein, Hemei Wang, Stefan Boehme, Andreas Vogt, Robert Kwiecien, Matthias David & Klaus Markstaller. (2012) Influence of crystalloid and colloid fluid infusion and blood withdrawal on pulmonary bioimpedance in an animal model of mechanical ventilation. Physiological Measurement 33:7, pages 1225-1236.
Crossref
E. Degirmenci & B. M. Eyuboglu. (2012) Image Reconstruction in Magnetic Resonance Conductivity Tensor Imaging (MRCTI). IEEE Transactions on Medical Imaging 31:3, pages 525-532.
Crossref
In?z Frerichs, Sven Pulletz, Gunnar Elke, Barbara Gawelczyk, Alexander Frerichs & Norbert Weiler. (2011) Patient examinations using electrical impedance tomography?sources of interference in the intensive care unit. Physiological Measurement 32:12, pages L1-L10.
Crossref
Mohanad Ahmad Shini, Shlomi Laufer & Boris Rubinsky. (2011) SVM for prostate cancer using electrical impedance measurements. Physiological Measurement 32:9, pages 1373-1387.
Crossref
Canhua Xu, Meng Dai, Fusheng You, Xuetao Shi, Feng Fu, Ruigang Liu & Xiuzhen Dong. (2011) An optimized strategy for real-time hemorrhage monitoring with electrical impedance tomography. Physiological Measurement 32:5, pages 585-598.
Crossref
FLORIAN REIFFERSCHEID, GUNNAR ELKE, SVEN PULLETZ, BARBARA GAWELCZYK, INGMAR LAUTENSCHL?GER, MARKUS STEINFATH, NORBERT WEILER & IN?Z FRERICHS. (2011) Regional ventilation distribution determined by electrical impedance tomography: Reproducibility and effects of posture and chest plane. Respirology 16:3, pages 523-531.
Crossref
Youn-Suk ChoiHong-Bae KimJunho ChungHyung-Sik KimJeong-Han YiJe-Kyun Park. (2010) Preclinical Analysis of Irreversible Electroporation on Rat Liver Tissues Using a Microfabricated Electroporator. Tissue Engineering Part C: Methods 16:6, pages 1245-1253.
Crossref
C-H Xu, L Wang, X-T Shi, F-S You, F Fu, R-G Liu, M Dai, Z-W Zhao, G-D Gao & X-Z Dong. (2010) Real-Time Imaging and Detection of Intracranial Haemorrhage by Electrical Impedance Tomography in a Piglet Model. Journal of International Medical Research 38:5, pages 1596-1604.
Crossref
Li Zhangyong, Xu Likun, Wei Jinmin, Liang Xiaoyan & Guo Yijun. (2010) Modeling the electrical characteristics of the stomach and reconstructing image. Modeling the electrical characteristics of the stomach and reconstructing image.
Fei Yang & Robert P. Patterson. (2010) A novel impedance-based tomography approach for stenotic plaque detection: A simulation study. International Journal of Cardiology 144:2, pages 279-283.
Crossref
Jiabin Jia, Mi Wang, H. Inaki Schlaberg & Hua Li. (2010) A novel tomographic sensing system for high electrically conductive multiphase flow measurement. Flow Measurement and Instrumentation 21:3, pages 184-190.
Crossref
T Yamaguchi, K Maki & M Katashima. (2010) Practical human abdominal fat imaging utilizing electrical impedance tomography. Physiological Measurement 31:7, pages 963-978.
Crossref
Archontis Giannakidis & Maria Petrou. 2010. Advances in Imaging and electron Physics. Advances in Imaging and electron Physics 129 172 .
Zheng Xu, Qian Li & Wei He. 2010. Life System Modeling and Intelligent Computing. Life System Modeling and Intelligent Computing 42 50 .
Rodrigo Alecio Stiz, Pedro Bertemes, Airton Ramos & Volney Coelho Vincence. (2009) Wide Band Howland Bipolar Current Source using AGC Amplifier. IEEE Latin America Transactions 7:5, pages 514-518.
Crossref
R.J. Sadleir, Te Tang, A.S. Tucker, P. Borum & M. Weiss. (2009) Detection of intraventricular blood using EIT in a neonatal piglet model. Detection of intraventricular blood using EIT in a neonatal piglet model.
A. Ivorra, M. Shini & B. Rubinsky. (2009) Linear Superposition Electrical Impedance Tomography Imaging With Multiple Electrical/Biopsy Probes. IEEE Transactions on Biomedical Engineering 56:5, pages 1465-1472.
Crossref
Jun Gu, W. Yin, Yannian Rui, Chao Wang & Huaxiang Wang. (2009) A new resistor network based forward model for electrical impedance tomography sensors. A new resistor network based forward model for electrical impedance tomography sensors.
R J Sadleir & Te Tang. (2009) Electrode configurations for detection of intraventricular haemorrhage in the premature neonate. Physiological Measurement 30:1, pages 63-79.
Crossref
Jin Keun Seo & Eung Je Woo. 2009. Mathematical Modeling in Biomedical Imaging I. Mathematical Modeling in Biomedical Imaging I 1 71 .
Michal M. Radai, Marina Arad, Sharon Zlochiver, Haim Krief, Tzvika Engelman & Shimon Abboud. (2008) A Novel Telemedicine System for Monitoring Congestive Heart Failure Patients. Congestive Heart Failure 14:5, pages 239-244.
Crossref
Xinfu Liu, Jinhe Liu, Zhanping Du, Quanming Zhao, Junying Zhao & Yuhui Huang. (2008) The Research on Non-destructive Testing Method of Sheet Resistance in Micro Area of Silicon Wafer Based on EIT Technology. The Research on Non-destructive Testing Method of Sheet Resistance in Micro Area of Silicon Wafer Based on EIT Technology.
R E Sokolovsky, S Zlochiver & S Abboud. (2008) Stroke volume estimation in heart failure patients using bioimpedance: a realistic simulation of the forward problem. Physiological Measurement 29:6, pages S139-S149.
Crossref
Mohanad Shini & Boris Rubinsky. (2008) Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography. Physiological Measurement 29:1, pages 109-126.
Crossref
Kim Hwa Lim, Guining Shi, Kyle McCarter, Rhett George, Gary Ybarra, William T. Joines, Scott Wartenberg & Qing Huo Liu. (2007) 2D EIT for biomedical imaging: Design, measurement, simulation, and image reconstruction. Microwave and Optical Technology Letters 49:12, pages 2989-2998.
Crossref
Hao Wang, Guo qiang Liu, Lingtong Jiang & Shiqiang Li. (2007) Inverse Problem of Magnetoacoustic Tomography with Magnetic Induction. Inverse Problem of Magnetoacoustic Tomography with Magnetic Induction.
Qingyu Ma & Bin He. (2007) Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction. Physics in Medicine and Biology 52:16, pages 5085-5099.
Crossref
Jianjun Zhang, Weili Yan, Guizhi Xu & Quanming Zhao. (2007) A New Algorithm to Reconstruct EIT Images: Node-Back-Projection Algorithm. A New Algorithm to Reconstruct EIT Images: Node-Back-Projection Algorithm.
Guizhi Xu, Renping Wang, Shuai Zhang, Shuo Yang, Gusphyl A. Justin, Mingui Sun & Weili Yan. (2007) A 128-Electrode Three Dimensional Electrical Impedance Tomography System. A 128-Electrode Three Dimensional Electrical Impedance Tomography System.
Hamid Dehghani & Manuchehr Soleimani. (2007) Numerical modelling errors in electrical impedance tomography. Physiological Measurement 28:7, pages S45-S55.
Crossref
Yair Granot, Antoni Ivorra & Boris Rubinsky. (2007) Frequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications. International Journal of Biomedical Imaging 2007, pages 1-9.
Crossref
. 2007. Bioimpedance and Bioelectricity Basics. Bioimpedance and Bioelectricity Basics 435 459 .
M. Rafiei-Naeini, P. Wright & H. McCann. 2007. 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography 324 327 .
Haluk Altunel, B. M. Eyüboğlu & A. Köksal. 2007. World Congress on Medical Physics and Biomedical Engineering 2006. World Congress on Medical Physics and Biomedical Engineering 2006 3940 3943 .
Canhua Xu, Xiuzhen Dong, Feng Fu, Wanjun Shuai, Xiaodong Liu & Chan Zhang. 2007. World Congress on Medical Physics and Biomedical Engineering 2006. World Congress on Medical Physics and Biomedical Engineering 2006 3882 3885 .
Sven Pulletz, Huibert R van Genderingen, Gunnar Schmitz, Günther Zick, Dirk Schädler, Jens Scholz, Norbert Weiler & Inez Frerichs. (2006) Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT. Physiological Measurement 27:5, pages S115-S127.
Crossref
D Barber. 2006. Medical Devices and Systems. Medical Devices and Systems 17-1 17-14 .
B. Murat Eyüboglu. 2006. Wiley Encyclopedia of Biomedical Engineering. Wiley Encyclopedia of Biomedical Engineering.
Sverre Grimnes & Ørjan G. Martinsen. 2006. Wiley Encyclopedia of Biomedical Engineering. Wiley Encyclopedia of Biomedical Engineering.
J Jossinet, A Fournier-Desseux & A Matias. (2006) Assessment of electrical impedance endotomography for hardware specification. Biomedical Imaging and Intervention Journal 2:2.
Crossref
Ohin Kwon, Hyunchan Pyo, Jin Keun Seo & Eung Je Woo. (2006) Mathematical framework for Bz-based MREIT model in electrical impedance imaging. Computers & Mathematics with Applications 51:5, pages 817-828.
Crossref
Jianjun Zhang, Guizhi Xu, Quanming Zhao & Weili Yan. (2006) Using Polynomial Curve Fitting Method to Improve Image Quality in EIT. Using Polynomial Curve Fitting Method to Improve Image Quality in EIT.
Zhang Shuai, Xu Guizhi, Wu Huanli, Geng Duyan & Yan Weili. (2006) Multi-frequency EIT Hardware System Based on DSP. Multi-frequency EIT Hardware System Based on DSP.
I. Frerichs, J. Scholz & N. Weiler. 2006. Yearbook of Intensive Care and Emergency Medicine. Yearbook of Intensive Care and Emergency Medicine 437 447 .
I. Frerichs, J. Scholz & N. Weiler. 2006. Intensive Care Medicine. Intensive Care Medicine 437 447 .
Anne Fournier-Desseux & Jacques Jossinet. (2005) Assessment of 1-lead and 2-lead electrode patterns in electrical impedance endotomography. Physiological Measurement 26:4, pages 337-349.
Crossref
Nuo Gao, Shan-an Zhu & Bin He. (2005) Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study. Journal of Zhejiang University-SCIENCE B 6:5, pages 438-445.
Crossref
J.F. Edd, L. Horowitz & B. Rubinsky. (2005) Temperature Dependence of Tissue Impedivity in Electrical Impedance Tomography of Cryosurgery. IEEE Transactions on Biomedical Engineering 52:4, pages 695-701.
Crossref
Suk Hoon Oh, Byung Il Lee, Eung Je Woo, Soo Yeol Lee, Tae-Seong Kim, Ohin Kwon & Jin Keun Seo. (2005) Electrical conductivity images of biological tissue phantoms in MREIT. Physiological Measurement 26:2, pages S279-S288.
Crossref
Hamid Dehghani, Nirmal Soni, Ryan Halter, Alex Hartov & Keith D Paulsen. (2005) Excitation patterns in three-dimensional electrical impedance tomography. Physiological Measurement 26:2, pages S185-S197.
Crossref
R. V. Davalos, L. M. Mir & B. Rubinsky. (2005) Tissue Ablation with Irreversible Electroporation. Annals of Biomedical Engineering 33:2, pages 223-231.
Crossref
Jin Keun Seo, Ohin Kwon & Eung Je Woo. (2005) Magnetic resonance electrical impedance tomography (MREIT): conductivity and current density imaging. Journal of Physics: Conference Series 12, pages 140-155.
Crossref
L. X. Liu, W. W. Dong, J. Wang, Q. Wu, W. He & Y. J. Jia. 2005. Intracranial Pressure and Brain Monitoring XII. Intracranial Pressure and Brain Monitoring XII 137 140 .
Gary Saulnier. 2004. Electrical Impedance Tomography. Electrical Impedance Tomography.
Eung Je Woo, Jin Keun Seo & Soo Yeol Lee. 2004. Electrical Impedance Tomography. Electrical Impedance Tomography.
David Holder. 2004. Electrical Impedance Tomography. Electrical Impedance Tomography.
Trevor York. 2004. Electrical Impedance Tomography. Electrical Impedance Tomography.
L. Tugan Muftuler, Mark Hamamura, Ozlem Birgul & Orhan Nalcioglu. (2016) Resolution and Contrast in Magnetic Resonance Electrical Impedance Tomography (MREIT) and its Application to Cancer Imaging. Technology in Cancer Research & Treatment 3:6, pages 599-609.
Crossref
J.K. Seo, O. Kwon, H. Ammari & E.J. Woo. (2004) A Mathematical Model for Breast Cancer Lesion Estimation: Electrical Impedance Technique Using TS2000 Commercial System. IEEE Transactions on Biomedical Engineering 51:11, pages 1898-1906.
Crossref
Jin Keun Seo, Hyun Chan Pyo, Chunjae Park, Ohin Kwon & Eung Je Woo. (2004) Image reconstruction of anisotropic conductivity tensor distribution in MREIT: computer simulation study. Physics in Medicine and Biology 49:18, pages 4371-4382.
Crossref
G. Xu, Q. Yang, S. Yang, F. Liu & W. Yan. (2004) Electrical Characteristics of Real Head Model Based on Electrical Impedance Tomography. IEEE Transactions on Appiled Superconductivity 14:2, pages 1617-1620.
Crossref
R H Ireland, J C Tozer, A T Barker & D C Barber. (2004) Towards magnetic detection electrical impedance tomography: data acquisition and image reconstruction of current density in phantoms and in vivo . Physiological Measurement 25:3, pages 775-796.
Crossref
U ur Baysal & Jens Haueisen. (2004) Use of a priori information in estimating tissue resistivities—application to human data in vivo . Physiological Measurement 25:3, pages 737-748.
Crossref
Rafael Davalos & Boris Rubinsky. (2004) Electrical Impedance Tomography of Cell Viability in Tissue With Application to Cryosurgery. Journal of Biomechanical Engineering 126:2, pages 305-309.
Crossref
R.V. Davalos, D.M. Otten, L.M. Mir & B. Rubinsky. (2004) Electrical Impedance Tomography for Imaging Tissue Electroporation. IEEE Transactions on Biomedical Engineering 51:5, pages 761-767.
Crossref
David M. Otten, Gary Onik & Boris Rubinsky. (2016) Distributed Network Imaging and Electrical Impedance Tomography of Minimally Invasive Surgery. Technology in Cancer Research & Treatment 3:2, pages 125-134.
Crossref
C. Park, O. Kwon, E.J. Woo & J.K. Seo. (2004) Electrical Conductivity Imaging Using Gradient<tex>$B_z$</tex>Decomposition Algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT). IEEE Transactions on Medical Imaging 23:3, pages 388-394.
Crossref
Shekhar Bhansali, Helen Benjamin, Vandana Upadhyay, H. Thurman Henderson, Chong H. Ahn, Nihat Okulan & Kwang Wook Oh. (2004) Modeling multilayered MEMS-based micro-fluidic systems. JOM 56:3, pages 57-61.
Crossref
Jacques Jossinet & Anne Desseux. (2004) Electrical impedance endotomography: sensitivity distribution against bipolar current patterns. Physiological Measurement 25:1, pages 355-364.
Crossref
F Thiel & C Hartung. (2004) Multikanalsystem zur nichtinvasiven Funktions- und Zustandsanalyse von Organen und Gewebe / A Multichannel Device for the Noninvasive Analysis of the State and Function of Organs and Tissues. Biomedizinische Technik/Biomedical Engineering 49:9, pages 233-237.
Crossref
Guizhi Xu, Qing Wu, Qingxin Yang, Ying Li & Weili Yan. (2004) A reconstruction algorithm based on wavelet network in electrical impedance tomography. A reconstruction algorithm based on wavelet network in electrical impedance tomography.
Suk Hoon Oh, Byung Il Lee, Eung Je Woo, Soo Yeol Lee, Min Hyoung Cho, Ohin Kwon & Jin Keun Seo. (2003) Conductivity and current density image reconstruction using harmonic B z algorithm in magnetic resonance electrical impedance tomography . Physics in Medicine and Biology 48:19, pages 3101-3116.
Crossref
Rafael V. Davalos, Boris Rubinsky & Lluis M. Mir. (2003) Theoretical analysis of the thermal effects during in vivo tissue electroporation. Bioelectrochemistry 61:1-2, pages 99-107.
Crossref
Andrew P Bagshaw, Adam D Liston, Richard H Bayford, Andrew Tizzard, Adam P Gibson, A.Thomas Tidswell, Matthew K Sparkes, Hamid Dehghani, Colin D Binnie & David S Holder. (2003) Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method. NeuroImage 20:2, pages 752-764.
Crossref
Byung Il Lee, Suk Hoon Oh, Eung Je Woo, Soo Yeol Lee, Min Hyoung Cho, Ohin Kwon, Jin Keun Seo, June-Yub Lee & Woon Sik Baek. (2003) Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes. Physics in Medicine and Biology 48:13, pages 1971-1986.
Crossref
 zlem Birg l, B Murat Ey boglu & Y Ziya Ider. (2003) Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns. Physics in Medicine and Biology 48:5, pages 653-671.
Crossref
Y Zou & Z Guo. (2003) A review of electrical impedance techniques for breast cancer detection. Medical Engineering & Physics 25:2, pages 79-90.
Crossref
Ohin Kwon, Jeong Rock Yoon, Jin Keun Seo, Eung Je Woo & Young Gu Cho. (2003) Estimation of anomaly location and size using electrical impedance tomography. IEEE Transactions on Biomedical Engineering 50:1, pages 89-96.
Crossref
Wuliang Yin & Huaxiang Wang. (2003) An image reconstruction algorithm based on matrix direct inverse for electrical resistance tomography. An image reconstruction algorithm based on matrix direct inverse for electrical resistance tomography.
Guizhi Xu, Qingxin Yang, Ying Li, Qing Wu & Weili Yan. (2003) The electrical properties of real head model based on electrical impedance tomography (EIT). The electrical properties of real head model based on electrical impedance tomography (EIT).
B.L.P. da Silva, F.R. Avila & M.N. Souza. (2003) Results of an EIT prototype able to supply static images. Results of an EIT prototype able to supply static images.
Cornelius T. Leondes. 2002. Computational Methods in Biophysics, Biomaterials, Biotechnology and Medical Systems. Computational Methods in Biophysics, Biomaterials, Biotechnology and Medical Systems 1177 1199 .
Jacques Jossinet, Emmanuel Marry & Adrien Matias. (2002) Electrical impedance endotomography. Physics in Medicine and Biology 47:13, pages 2189-2202.
Crossref
J. Jossinet, E. Marry & A. Montalibet. (2002) Electrical impedance endo-tomography: imaging tissue from inside. IEEE Transactions on Medical Imaging 21:6, pages 560-565.
Crossref
N. Polydorides, W.R.B. Lionheart & H. McCann. (2002) Krylov subspace iterative techniques: on the detection of brain activity with electrical impedance tomography. IEEE Transactions on Medical Imaging 21:6, pages 596-603.
Crossref
Hyun Soo Khang, Byung Il Lee, Suk Hoon Oh, Eung Je Woo, Soo Yeol Lee, Min Hyoung Cho, Ohin Kwon, Jeong Rock Yoon & Jin Keun Seo. (2002) J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images. IEEE Transactions on Medical Imaging 21:6, pages 695-702.
Crossref
A. Koksal, M. Eyuboglu & M. Demirbilek. (2002) A quasi-static analysis for a class of induced-current EIT systems using discrete coils. IEEE Transactions on Medical Imaging 21:6, pages 688-694.
Crossref
S. Levy, D. Adam & Y. Bresler. (2002) Electromagnetic impedance tomography (EMIT): a new method for impedance imaging. IEEE Transactions on Medical Imaging 21:6, pages 676-687.
Crossref
R.V. Davalos, B. Rubinsky & D.M. Otten. (2002) A feasibility study for electrical impedance tomography as a means to monitor tissue electroporation for molecular medicine. IEEE Transactions on Biomedical Engineering 49:4, pages 400-403.
Crossref
Victor P. Palamodov. (2002) Gabor analysis of the continuum model for impedance tomography. Arkiv för Matematik 40:1, pages 169-187.
Crossref
C A González-Correa, G Screaton, D R Hose, B H Brown, N J Avis & F Kleinermann. (2002) Resistivity changes in conductive silicone sheets under stretching. Physiological Measurement 23:1, pages 183-188.
Crossref
Ohin Kwon, Eung Je Woo, Jeong-Rock Yoon & Jin Keun Seo. (2002) Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm. IEEE Transactions on Biomedical Engineering 49:2, pages 160-167.
Crossref
M Wang. (2002) Inverse solutions for electrical impedance tomography based on conjugate gradients methods. Measurement Science and Technology 13:1, pages 101-117.
Crossref
Brian H Brown. (2001) Medical impedance tomography and process impedance tomography: a brief review. Measurement Science and Technology 12:8, pages 991-996.
Crossref
Trevor York. (2001) Status of electrical tomography in industrial applications. Journal of Electronic Imaging 10:3, pages 608.
Crossref
D. Jennings & I. D. Schneider. (2001) Front-end architecture for a multifrequency electrical impedance tomography system. Medical & Biological Engineering & Computing 39:3, pages 368-374.
Crossref
R.J. Sadleir & R.A. Fox. (2001) Detection and quantification of intraperitoneal fluid using electrical impedance tomography. IEEE Transactions on Biomedical Engineering 48:4, pages 484-491.
Crossref
Y.G. Cho, O. Kwon, J.K. Seo, E.J. Woo & J.R. Yoon. (2001) Anomaly detection using impedance measurements on the boundary. Anomaly detection using impedance measurements on the boundary.
O. Kwon, J.K. Seo, E.J. Woo, J.R. Yoon, S.Y. Lee & M.H. Cho. (2001) Resistivity image reconstruction using J-substitution algorithm for MREIT. Resistivity image reconstruction using J-substitution algorithm for MREIT.
M. P. O'Connell, J. Tidy, S. J. Wisher, N. J. Avis, B. H. Brown & S. W. Lindow. (2005) An in vivo comparative study of the pregnant and nonpregnant cervix using electrical impedance measurements . BJOG: An International Journal of Obstetrics & Gynaecology 107:8, pages 1040-1041.
Crossref
Ugur Baysal & B Murat Eyüboglu. (2000) Tissue resistivity estimation in the presence of positional and geometrical uncertainties. Physics in Medicine and Biology 45:8, pages 2373-2388.
Crossref
B Murat Eyüboglu, Adnan Köksal & Mehmet Demirbilek. (2000) Distinguishability analysis of an induced current EIT system using discrete coils. Physics in Medicine and Biology 45:7, pages 1997-2009.
Crossref
R. Kleffel, I. D. Schneider & D. Jennings. (2000) Synthesis of a digitally controlled impedance element. Medical & Biological Engineering & Computing 38:4, pages 395-400.
Crossref
Inéz Frerichs. (2000) Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. Physiological Measurement 21:2, pages R1-R21.
Crossref
F Kleinermann, N J Avis & F A Alhargan. (2000) Analytical solution to the three-dimensional electrical forward problem for a circular cylinder. Inverse Problems 16:2, pages 461-468.
Crossref
C M Towers, H McCann, M Wang, P C Beatty, C J D Pomfrett & M S Beck. (2000) 3D simulation of EIT for monitoring impedance variations within the human head. Physiological Measurement 21:1, pages 119-124.
Crossref
R. J. Sadleir, R. A. Fox & V. F. Turner. (2000) Inflatable belt for the application of electrode arrays . Review of Scientific Instruments 71:2, pages 530-535.
Crossref
D.M. Otten & B. Rubinsky. (2000) Cryosurgical monitoring using bioimpedance measurements-a feasibility study for electrical impedance tomography. IEEE Transactions on Biomedical Engineering 47:10, pages 1376-1381.
Crossref
Florian E. W. Schmidt, Martin E. Fry, Elizabeth M. C. Hillman, Jeremy C. Hebden & David T. Delpy. (2000) A 32-channel time-resolved instrument for medical optical tomography. Review of Scientific Instruments 71:1, pages 256-265.
Crossref
D Barber. 1999. The Biomedical Engineering Handbook, Second Edition. 2 Volume Set. The Biomedical Engineering Handbook, Second Edition. 2 Volume Set.
Gerard H. Markx & Christopher L. Davey. (1999) The dielectric properties of biological cells at radiofrequencies: applications in biotechnology. Enzyme and Microbial Technology 25:3-5, pages 161-171.
Crossref
N.G. Gencer & M.N. Tek. (1999) Electrical conductivity imaging via contactless measurements. IEEE Transactions on Medical Imaging 18:7, pages 617-627.
Crossref
Ugur Baysal & B Murat Eyüboglu. (1999) Use of a priori information in estimating tissue resistivities - application to measured data . Physics in Medicine and Biology 44:7, pages 1677-1689.
Crossref
Pasi K Kauppinen, Jari A.K Hyttinen, Tiit K??bi & Jaakko Malmivuo. (1999) Multiple lead recordings improve accuracy of bio-impedance plethysmographic technique. Medical Engineering & Physics 21:5, pages 371-375.
Crossref
Kyungho Cho & Sin Kim. (1999) Adaptive mesh grouping in electrical impedance tomography for bubble visualization. KSME International Journal 13:6, pages 504-515.
Crossref
MICHAL M. RADAI, SHIMON ABBOUD & MOSHE ROSENFELD. (1999) Evaluation of Impedance Technique for Detecting Breast Carcinoma Using a 2-D Numerical Model of the Torso. Annals of the New York Academy of Sciences 873:1 ELECTRICAL BI, pages 360-369.
Crossref
Nevzat G Gençer & M Nejat Tek. (1999) Forward problem solution for electrical conductivity imaging via contactless measurements. Physics in Medicine and Biology 44:4, pages 927-940.
Crossref
Michal M. Radai, Shimon Abboud & Boris Rubinsky. (1999) Evaluation of the Impedance Technique for Cryosurgery in a Theoretical Model of the Head. Cryobiology 38:1, pages 51-59.
Crossref
O. Birgui, B.M. Eyuboglu & Y.Z. Ider. (1999) Magnetic resonance conductivity imaging. Magnetic resonance conductivity imaging.
M. Eyuboglu, A. Koksal & M. Demirbilek. (1999) Discrete coil induced current impedance tomography. Discrete coil induced current impedance tomography.
Ugur Baysal & B Murat Eyüboglu. (1998) Use of a priori information in estimating tissue resistivities - a simulation study . Physics in Medicine and Biology 43:12, pages 3589-3606.
Crossref
B Hofmann. (1998) Approximation of the inverse electrical impedance tomography problem by an inverse transmission problem. Inverse Problems 14:5, pages 1171-1187.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.