419
Views
17
CrossRef citations to date
0
Altmetric
Research Article

An implementation to read and write IAEA phase-space files in GEANT4-based simulations

, , &
Pages 200-208 | Received 30 Mar 2011, Accepted 23 Sep 2011, Published online: 18 Nov 2011

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Sandra Oliver, Belén Juste, Rafael Miró & Gumersindo Verdú. (2023) Toolkit implementation to exchange phase-space files between IAEA and MCNP6 monte Carlo code format. International Journal of Radiation Biology 99:3, pages 373-383.
Read now

Articles from other publishers (16)

Sreekala Unnikrishnan, S K Gupta, P Raghukumar & N S Shine. (2023) Monte carlo simulation of electron beams from varian truebeam linear accelerator used in radiotherapy: estimation of initial beam parameters. Journal of Physics: Conference Series 2603:1, pages 012042.
Crossref
Linda Laakkonen, Jouko Lehtomäki, Alexander Cahill, Magdalena Constantin, Antti Kulmala & Ari Harju. (2023) Monte Carlo modeling of Halcyon and Ethos radiotherapy beam using CAD geometry: validation and IAEA-compliant phase space. Physics in Medicine & Biology 68:4, pages 044002.
Crossref
Selvaraj Balaji, Chung-Chi Lee, Tsukasa Aso, Tung-Ho Wu, Yueh Chiang, Luu Dang Hoang Oanh, Chien-Kai Tseng, Chia-Ray Chen & Tsi-Chian Chao. (2022) Investigation of the effects of the step size of Geant4 electromagnetic physics on the depth dose simulation of a small field proton beam. Radiation Physics and Chemistry 195, pages 110050.
Crossref
Omrane Kadri & Abdulrahman Alfuraih. (2022) Buildup Factor Computation and Percentage Depth Dose Simulation of Tissue Mimicking Materials for an External Photon Beam (0.15–15 MeV). Applied Sciences 12:9, pages 4250.
Crossref
Taha Hachemi, Zine-El-Abidine Chaoui & Saad Khoudri. (2021) PENELOPE simulations and experiment for 6 MV clinac iX accelerator for standard and small static fields. Applied Radiation and Isotopes 174, pages 109749.
Crossref
Bin Zhang, Tian-Ci Xie, Zhuang Qin, Hao-Peng Li, Song Li, Wen-Hui Zhao, Zi-Yin Chen, Jun Xu, Elfed Lewis & Wei-Min Sun. (2021) GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor*. Chinese Physics B 30:4, pages 048701.
Crossref
Zhenguo Cui, Songlin Sha & Yanling Bai. (2021) A structural analytic method on the phase space data of Linac 4 MV photons based on the real world. Physica Medica 82, pages 109-113.
Crossref
Tae Hoon Kim, Thomas Schaarschmidt, Hye Jeong Yang, Yong Kyun Kim, Kook Jin Chun, Yona Choi & Hyun-Tai Chung. (2019) Development of an IAEA phase-space dataset for the Leksell Gamma Knife® Perfexion™ using multi-threaded Geant4 simulations. Physica Medica 64, pages 222-229.
Crossref
Juliana Cristina Martins, Rangoli Saxena, Sebastian Neppl, Abdulaziz Alhazmi, Michael Reiner, Stella Veloza, Claus Belka & Katia Parodi. (2019) Optimization of Phase Space files from clinical linear accelerators. Physica Medica 64, pages 54-68.
Crossref
Giordano Biasi, Marco Petasecca, Susanna Guatelli, Ebert A. Martin, Garry Grogan, Benjamin Hug, Jonathan Lane, Vladimir Perevertaylo, Tomas Kron & Anatoly B. Rosenfeld. (2018) CyberKnife ® fixed cone and Iris™ defined small radiation fields: Assessment with a high-resolution solid-state detector array . Journal of Applied Clinical Medical Physics 19:5, pages 547-557.
Crossref
Rangoli Saxena, Juliana Cristina Martins, Abdulaziz Alhazmi, Sebastian Neppl, Michael Reiner, Claus Belka, Stella Veloza & Katia Parodi. (2018) [OA029] Optimization of phase space files from clinical linear accelerators. Physica Medica 52, pages 12.
Crossref
Zakaria Aboulbanine & Naïma El Khayati. (2018) Validation of a virtual source model of medical linac for Monte Carlo dose calculation using multi-threaded Geant4. Physics in Medicine & Biology 63:8, pages 085008.
Crossref
Á. Perales, M.A. Cortés-Giraldo, H. Miras, R. Arráns & M.I. Gallardo. (2017) Dosimetric impact assessment using a general algorithm in geant4 simulations for a complex-shaped multileaf collimator. Physica Medica 41, pages 39-45.
Crossref
Jaafar EL Bakkali & Tarek EL Bardouni. (2017) Validation of Monte Carlo Geant4 code for a 6 MV Varian linac. Journal of King Saud University - Science 29:1, pages 106-113.
Crossref
M A Cortés-Giraldo & A Carabe. (2015) A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams. Physics in Medicine and Biology 60:7, pages 2645-2669.
Crossref
Alexis Rucci, Claudia Carletti, Walter Cravero & Bojan Strbac. (2014) Use of IAEA's phase-space files for the implementation of a clinical accelerator virtual source model. Physica Medica 30:2, pages 242-248.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.