Problems Associated with Clinical Chemistry Quality Control Materials

, &
Pages 59-86 | Published online: 27 Sep 2008

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Ana-Maria Simundic, Geoffrey Baird, Janne Cadamuro, Seán J. Costelloe & Giuseppe Lippi. (2020) Managing hemolyzed samples in clinical laboratories. Critical Reviews in Clinical Laboratory Sciences 57:1, pages 1-21.
Read now
Robert Rej & Patricia Drake. (1991) The Nature of Calibrators in Immunoassays: Are they Commutable with Test Samples? Must they Be?. Scandinavian Journal of Clinical and Laboratory Investigation 51:sup205, pages 47-54.
Read now
A. Uldall. (1987) Quality assurance within clinical chemistry—a brief review emphasizing ‘good laboratory practice’. Scandinavian Journal of Clinical and Laboratory Investigation 47:5, pages 507-518.
Read now
. (1987) 7. Bibliography. Scandinavian Journal of Clinical and Laboratory Investigation 47:sup187, pages 76-91.
Read now
Noel S. Lawson, Guy T. Haven & George W. Williams. (1982) Analyte Stability in Clinical Chemistry Quality Control Materials. CRC Critical Reviews in Clinical Laboratory Sciences 17:1, pages 1-50.
Read now

Articles from other publishers (20)

Christian V. Hulzebos, Libor Vitek, Carlos D. Coda Zabetta, Aleš Dvořák, Paul Schenk, Eline A. E. van der Hagen, Christa Cobbaert & Claudio Tiribelli. (2021) Diagnostic methods for neonatal hyperbilirubinemia: benefits, limitations, requirements, and novel developments. Pediatric Research 90:2, pages 277-283.
Crossref
Yoji Hirabayashi, Yutaka Tsukada, Takuya Sakurai, Hideki Ohno & Takako Kizaki. (2020) Comparative evaluation of methods to determine intra‐individual reference ranges in nutrition support team (NST)‐related tests. Journal of Clinical Laboratory Analysis 35:2.
Crossref
Giuseppe Lippi, Janne Cadamuro, Elisa Danese, Matteo Gelati, Martina Montagnana, Alexander von Meyer, Gian Luca Salvagno & Ana-Maria Simundic. (2018) Internal quality assurance of HIL indices on Roche Cobas c702. PLOS ONE 13:7, pages e0200088.
Crossref
Randolph M. Baral, Navneet K. Dhand & Kathleen P. Freeman. (2016) Commutability and interchangeability of commercial quality control materials with feline plasma for common biochemical analytes. Veterinary Clinical Pathology 45:2, pages 300-310.
Crossref
Randolph M. Baral, John M. Morton, Navneet K. Dhand, Mark B. Krockenberger & Merran Govendir. (2014) Repeatability of results from three in-house biochemistry analyzers and a commercial laboratory analyzer used in small animal practice. Comparative Clinical Pathology 24:4, pages 755-765.
Crossref
Aljoscha Neubauer, Christian Wolter, Christine Falkner & Dieter Neumeier. (1998) Optimizing frequency and number of controls for automatic multichannel analyzers. Clinical Chemistry 44:5, pages 1014-1023.
Crossref
Gianvico Melzi d'Eril, Adriano Anesi, Vittoria Rizzo & Rosita Trotti. (1997) Biological Variation in Protein C, Protein S and Antithrombin Concentrations in Plasma of Healthy Subjects. Clinical Chemistry and Laboratory Medicine 35:4.
Crossref
Callum G. Fraser. (2011) Quality assurance in clinical biochemistry. Proceedings of the Royal Society of Edinburgh. Section B. Biological Sciences 101, pages 251-261.
Crossref
Philip E. Gardiner. (1993) Considerations in the preparation of biological and environmental reference materials for use in the study of the chemical speciation of trace elements. Fresenius' Journal of Analytical Chemistry 345:2-4, pages 287-290.
Crossref
. (1992) Report. Clinical Chemistry and Laboratory Medicine 30:5.
Crossref
C.G. Fraser. (1990) The Necessity of Achieving Good Laboratory Performance. Diabetic Medicine 7:6, pages 490-493.
Crossref
S T Cummings & C G Fraser. (2016) The Authors Reply. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 27:1, pages 96-96.
Crossref
John H. Lumsden & Robert M. Jacobs. (1989) Clinical Chemistry. Veterinary Clinics of North America: Small Animal Practice 19:5, pages 875-897.
Crossref
Herbert K. Naito. (1989) The Need for Accurate Total Cholesterol Measurement: Recommended Analytical Goals, Current State of Reliability, and Guidelines for Better Determinations. Clinics in Laboratory Medicine 9:1, pages 37-60.
Crossref
Callum G Fraser. (2016) Analytical Goals for Glucose Analyses. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 23:4, pages 379-389.
Crossref
M J Peake, Maria Pejakovic & C G Fraser. (2016) The Effect of Instrument Variables on Calculation Factors for Standardisation of Colorimetric Analyses. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine 21:3, pages 188-192.
Crossref
AndréP. De Leenheer, Herman L.C. Steyaert, Linda M.R. Thienpont & Jozef A. Jonckheere. (1983) External quality control of clinical chemistry laboratories in Belgium. Clinica Chimica Acta 133:1, pages 1-14.
Crossref
C.G. Fraser. 1983. Advances in Clinical Chemistry Volume 23. Advances in Clinical Chemistry Volume 23 299 339 .
C.R. Hearne, M.J. Peake, B.M. Duncan & C.G. Fraser. (1982) Comparison of standardization techniques for colorimetric analyses on a centrifugal analyzer. Clinical Biochemistry 15:3, pages 173-178.
Crossref
Klaus Jung, Gottfried Schreiber & Klaus D. Grützmann. (1982) Suitability of commercial control sera for the quality control of activity determination of gamma-glutamyl transferase. Clinica Chimica Acta 120:3, pages 367-371.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.