424
Views
36
CrossRef citations to date
0
Altmetric
Original Article

Metal ions in body fluids after arthroplasty

, , , , &
Pages 415-418 | Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

E. Chassot, H. Oudadesse, Y. Barbotteau, J. L. Irigaray, S. Terver, G. Vanneuville & Ph. Moretto. (2002) TENTATIVE FOR TRACE ELEMENTS EVALUATION BY PIXE METHOD VERSUS DEPTH IN SOFT TISSUES NEAR METALLIC IMPLANTS. Journal of Trace and Microprobe Techniques 20:4, pages 571-580.
Read now
Seppo Santavirta, Anthony Gristina & YrjÖ T. Konttinen. (1992) Cemented versus cementless hip arthroplasty A review of prosthetic biocompatibility. Acta Orthopaedica Scandinavica 63:2, pages 225-232.
Read now
Courtland G. Lewis, Robert M. Belniak, Sidney M. Hopfer & F. William Sunderman. (1991) Cobalt in periprosthetic soft tissue: Observations in 6 revision cases. Acta Orthopaedica Scandinavica 62:5, pages 447-450.
Read now

Articles from other publishers (31)

Murat AKKUŞ. (2019) Pektus Bar’lı Olguların Serum ve İdrar Örneklerinde Eser Elementlerin Değerlendirilmesi. Dicle Tıp Dergisi 46:3, pages 499-504.
Crossref
Ghulam Khadija, Ayisha Saleem, Zafrin Akhtar, Zahra Naqvi, Maham Gull, Mahnoor Masood, Sana Mukhtar, Momna Batool, Nida Saleem, Tahir Rasheed, Naira Nizam, Ather Ibrahim & Furhan Iqbal. (2018) Short term exposure to titanium, aluminum and vanadium (Ti 6Al 4V) alloy powder drastically affects behavior and antioxidant metabolites in vital organs of male albino mice. Toxicology Reports 5, pages 765-770.
Crossref
Bikramjit BasuBikramjit Basu. 2017. Biomaterials for Musculoskeletal Regeneration. Biomaterials for Musculoskeletal Regeneration 253 289 .
Fabjola Bilo, Laura Borgese, Josef Prost, Mirjam Rauwolf, Anna Turyanskaya, Peter Wobrauschek, Peter Kregsamer, Christina Streli, Ugo Pazzaglia & Laura E. Depero. (2015) Atomic layer deposition to prevent metal transfer from implants: An X-ray fluorescence study. Applied Surface Science 359, pages 215-220.
Crossref
Burak Dikici, Ziya Esen, Ozgur Duygulu & Serap Gungor. 2015. Advances in Metallic Biomaterials. Advances in Metallic Biomaterials 275 303 .
Christina M. Arnholt, Daniel W. MacDonald, Mariya Tohfafarosh, Jeremy L. Gilbert, Clare M. Rimnac, Steven M. Kurtz, Gregg Klein, Michael A. Mont, Javad Parvizi, Harold E. Cates, Gwo-Chin Lee, Arthur Malkani & Mattheuw Kraay. (2014) Mechanically Assisted Taper Corrosion in Modular TKA. The Journal of Arthroplasty 29:9, pages 205-208.
Crossref
Mohammad Ali Saghiri, Armen Asatourian, Afshin Haraji, Golam H. Ramezani, Franklin Garcia-Godoy, Mark Scarbecz & Nader Sheibani. (2014) The Influence of Endodontic Broken Stainless Steel Instruments on the Urinary Levels of Iron. Biological Trace Element Research 158:3, pages 330-333.
Crossref
Vuong-Hung Pham, Seung-Hee Lee, Yuanlong Li, Hyoun-Ee Kim, Kwan-Ha Shin & Young-Hag Koh. (2013) Utility of tantalum (Ta) coating to improve surface hardness in vitro bioactivity and biocompatibility of Co–Cr. Thin Solid Films 536, pages 269-274.
Crossref
Yoshimitsu Okazaki & Emiko Gotoh. (2013) Metal ion effects on different types of cell line, metal ion incorporation into L929 and MC3T3-E1 cells, and activation of macrophage-like J774.1 cells. Materials Science and Engineering: C 33:4, pages 1993-2001.
Crossref
Michael M. Morlock, Joachim Kunze, Markus A. Wimmer & Christoph H. Lohmann. (2012) Metal-on-Metal: Ion Levels as an Intervention Strategy. Seminars in Arthroplasty 23:4, pages 283-285.
Crossref
B. Aksakal, M. Gavgali & B. Dikici. (2009) The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS Implants. Journal of Materials Engineering and Performance 19:6, pages 894-899.
Crossref
Ajay Malviya, Jayasree Ramaskandhan, James P. Holland & Elizabeth A. Lingard. (2010) Metal-on-Metal Total Hip Arthroplasty. Journal of Bone and Joint Surgery 92:7, pages 1675-1683.
Crossref
Rong Sen Yang, Huei Ping Tzeng, Feng Ming Ho, Chia Chi Chuang, Bo Lin Chen, Chun-Fa Huang, Ya-Wen Chen, Ruei Ming Chen & Shing Hwa Liu. (2009) Titanium implants alter endothelial function and vasoconstriction via a protein kinase C-regulated pathway. Acta Biomaterialia 5:8, pages 3258-3264.
Crossref
Sun Kyu Kim & Vuong Hung Pham. (2009) Cell adhesion property of cathodic arc plasma deposited CrN thin film. JOM 61:9, pages 59-62.
Crossref
M Khan, J H Kuiper & J B Richardson. (2007) Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty? . Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 221:8, pages 929-942.
Crossref
I Bruce McPhee & Cheryl E. Swanson. (2007) Metal Ion Levels in Patients With Stainless Steel Spinal Instrumentation. Spine 32:18, pages 1963-1968.
Crossref
E. Chassot, J.L. Irigaray, S. Terver & G. Vanneuville. (2005) Analytical method used for PIXE analyses. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 229:3-4, pages 479-488.
Crossref
A.K. Shukla, R. Balasubramaniam & S. Bhargava. (2005) Effect of replacement of V by Fe and Nb on passive film behavior of Ti?6Al?4V in simulated body fluid conditions. Journal of Alloys and Compounds 389:1-2, pages 144-152.
Crossref
Y Okazaki & E Gotoh. (2005) Corrosion Resistance, Mechanical Properties, Fatigue Properties, and Tissue Response of Ti-15Zr-4Nb-4Ta Alloy. Journal of ASTM International 2:9, pages 12783.
Crossref
Yoshimitsu Okazaki & Emiko Gotoh. (2005) Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26:1, pages 11-21.
Crossref
ROBERT M. URBAN, JOSHUA J. JACOBS, MICHAEL J. TOMLINSON, JOHN GAVRILOVIC, JONATHAN BLACK & MICHEL PEOC'H. (2000) Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement*. The Journal of Bone and Joint Surgery-American Volume 82:4, pages 457-477.
Crossref
Joshua J. Jacobs, Craig Silverton, Nadim J. Hallab, Anastasia K. Skipor, Leslie Patterson, Jonathan Black & Jorge O. Galante. (1999) Metal Release and Excretion From Cementless Titanium Alloy Total Knee Replacements. Clinical Orthopaedics and Related Research 358, pages 173???180.
Crossref
Yoshimitsu Okazaki, Sethumadhvan Rao, Shigeo Asao, Tetsuya Tateishi, Shin-ichi Katsuda & Yuko Furuki. (1998) Effects of Ti, Al and V Concentrations on Cell Viability. Materials Transactions, JIM 39:10, pages 1053-1062.
Crossref
Tang-Kue Liu, Shin-Hwa Liu, Chia-Hsieh Chang & Rong-Sen Yang. (1998) Concentration of Metal Elements in the Blood and Urine in the Patients with Cementless Total Knee Arthroplasty.. The Tohoku Journal of Experimental Medicine 185:4, pages 253-262.
Crossref
Tuomo Visuri, Pekka Pulkkinen, Pekka Paavolainen, Markku Koskenvuo & Kaj.B. Turula. (1997) Causes of death after hip arthroplasty in primary arthrosis. The Journal of Arthroplasty 12:4, pages 397-402.
Crossref
Tuomo Visuri, Eero Pukkala, Pekka Paavolainen, Pekka Pulkkinen & Erik B. Riska. (1996) Cancer Risk After Metal on Metal and Polyethylene on Metal Total Hip Arthroplasty. Clinical Orthopaedics and Related Research 329, pages S280-S289.
Crossref
G.C. McKay, R. Macnair, C. MacDonald & M.H. Grant. (1996) Interactions of orthopaedic metals with an immortalized rat osteoblast cell line. Biomaterials 17:13, pages 1339-1344.
Crossref
M. Browne & P.J. Gregson. (1995) Metal ion release from wear particles produced by Ti-6Al-4V and Co-Cr alloy surfaces articulating against bone. Materials Letters 24:1-3, pages 1-6.
Crossref
Katharine Merritt & Stanley A. Brown. (2004) Release of hexavalent chromium from corrosion of stainless steel and cobalt—chromium alloys. Journal of Biomedical Materials Research 29:5, pages 627-633.
Crossref
Stanley A. Brown, Kan Zhang, Katharine Merritt & Joe H. Payer. (2004) In vivo transport and excretion of corrosion products from accelerated anodic corrosion of porous coated F75 alloy . Journal of Biomedical Materials Research 27:8, pages 1007-1017.
Crossref
F. William SundermanJr.Jr., Sidney M. Hopfer, Thomas Swift, William N. Rezuke, Linda Ziebka, Paul Highman, Brian Edwards, Marilyn Folcik & Harry R. Gossling. (2005) Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prostheses. Journal of Orthopaedic Research 7:3, pages 307-315.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.