91
Views
21
CrossRef citations to date
0
Altmetric
Original Article

Plain radiographs inadequate for evaluation of the cement-bone interface in the hip prosthesis A cadaver study of femoral stems

, , , &
Pages 541-543 | Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (1)

Bengt Mjöberg. (1991) Fixation and loosening of hip prostheses. Acta Orthopaedica Scandinavica 62:5, pages 500-508.
Read now

Articles from other publishers (20)

Christian B. Scheele, Peter E. Müller, Christian Schröder, Thomas Grupp, Volkmar Jansson & Matthias F. Pietschmann. (2019) Accuracy of a non-invasive CT-based measuring technique for cement penetration depth in human tibial UKA. BMC Medical Imaging 19:1.
Crossref
S. Lee, B.T. Goh, H. Tideman, P.J.W. Stoelinga & J.A. Jansen. (2009) Modular endoprosthesis for mandibular body reconstruction: a clinical, micro-CT and histologic evaluation in eight Macaca fascicularis. International Journal of Oral and Maxillofacial Surgery 38:1, pages 40-47.
Crossref
P.D. Vaughan, P.J. Singh, R. Teare, R. Kucheria & G.C. Singer. (2018) Femoral Stem Tip Orientation and Surgical Approach in Total Hip Arthroplasty. HIP International 17:4, pages 212-217.
Crossref
Gavan P. Duffy, Andrew J. Lozynsky & William H. Harris. (2006) Polished vs Rough Femoral Components in Grade A and Grade C-2 Cement Mantles. The Journal of Arthroplasty 21:7, pages 1054-1063.
Crossref
Thierry Scheerlinck, Johan De Mey & Rudi Deklerck. (2005) In vitro analysis of the cement mantle of femoral hip implants: Development and validation of a CT-scan based measurement tool. Journal of Orthopaedic Research 23:4, pages 698-704.
Crossref
Steffen J. Breusch. 2005. The Well-Cemented Total Hip Arthroplasty. The Well-Cemented Total Hip Arthroplasty 125 140 .
B. Barden, B. Weßkamp, F. Löer & I. Michiels. (2004) Modified cemented stem fixation in hip arthroplasty with computer based analysis – Experimental results. Materialwissenschaft und Werkstofftechnik 34:12, pages 1155-1162.
Crossref
Friedrich Bottner & Thomas P. Sculco. (2001) Infection in Revision Total Hip Arthroplasty. Techniques in Orthopaedics 16:3, pages 310-322.
Crossref
Steffen J. Breusch, Martin Lukoschek, Jürgen Kreutzer, Dario Brocai & Thomas A. Gruen. (2001) Dependency of cement mantle thickness on femoral stem design and centralizer. The Journal of Arthroplasty 16:5, pages 648-657.
Crossref
M.E. Havinga, M. Spruit, P.G. Anderson, M.S.W. van Dijk-van Dam, P.W. Pavlov & J. van Limbeek. (2001) Results with the M. E. Müller cemented, straight-stem total hip prosthesis. The Journal of Arthroplasty 16:1, pages 33-36.
Crossref
Steffen J. Breusch. 2001. Bone Cements and Cementing Technique. Bone Cements and Cementing Technique 53 79 .
J. Christopher Banwart, David A. McQueen, Elizabeth A. Friis & Charles D. Graber. (2000) Negative pressure intrusion cementing technique for total knee arthroplasty. The Journal of Arthroplasty 15:3, pages 360-367.
Crossref
Robert J. Carangelo & Arnold D. Scheller. 1999. Revision Total Hip Arthroplasty. Revision Total Hip Arthroplasty 47 58 .
S. A. Brumby, D. W. Howie, M. J. Pearcy, A. W. Wang & N. S. Nawana. (1998) Radiographic and Histologic Analysis of Cemented Double Tapered Femoral Stems. Clinical Orthopaedics and Related Research 355, pages 229-237.
Crossref
Bengt Mjöberg. (1997) The Theory of Early Loosening of Hip Prostheses. Orthopedics 20:12, pages 1169-1175.
Crossref
S S Hughes, J P Furia, P Smith & V D PellegriniJrJr. (1995) Atrophy of the proximal part of the femur after total hip arthroplasty without cement. A quantitative comparison of cobalt-chromium and titanium femoral stems with use of dual x-ray absorptiometry.. The Journal of Bone & Joint Surgery 77:2, pages 231-239.
Crossref
Robert L Barrack. (1994) ASSESSMENT OF THE SYMPTOMATIC TOTAL HIP. Orthopedics 17:9, pages 793-795.
Crossref
U.E. Pazzaglia & S. Cattaneo. (2019) Bone-Cement Interface: Theory and Practice. HIP International 3:3-4, pages 63-65.
Crossref
Johan Kärrholm & Finnur Snorrason. (2005) Migration of porous coated acetabular prostheses fixed with screws: Roentgen stereophotogrammetric analysis. Journal of Orthopaedic Research 10:6, pages 826-835.
Crossref
Bengt Mj�berg. (1991) Letter to the editor. Archives of Orthopaedic and Trauma Surgery 110:3, pages 178-178.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.