338
Views
23
CrossRef citations to date
0
Altmetric
Original Article

Polyethylene failure in two total knees: Wear of thin, metal-backed PCA tibial components

, &
Pages 575-577 | Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Ching-Jen Wang, Henry E Wang & Wilfredo C Causing. (1997) Extraosseous granuloma after total knee arthroplasty–a case report. Acta Orthopaedica Scandinavica 68:4, pages 404-405.
Read now
Jun-Wen Wang & Cheng-Ching Lin. (1993) A case of massive osteolysis after knee prosthesis polyethylene failure. Acta Orthopaedica Scandinavica 64:4, pages 491-493.
Read now
Niek J. A. Tulp. (1992) Polyethylene delamination in the PCA total knee Material analysis in two failed cases. Acta Orthopaedica Scandinavica 63:3, pages 263-266.
Read now
Anders Lindstr & Anders Stenström. (1992) Polyethylene wear of the PCA unicompartmental knee. Acta Orthopaedica Scandinavica 63:3, pages 260-262.
Read now
Anders Lindstr, Anders Stenström & Stefan Lewold. (1992) Multicenter study of unicompartmental knee revision. Acta Orthopaedica Scandinavica 63:3, pages 256-259.
Read now

Articles from other publishers (18)

Matthew T. Houdek, Chad D. Watts, Cody C. Wyles, John R. Martin, Robert T. Trousdale & Michael J. Taunton. (2017) Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis. The Journal of Arthroplasty 32:3, pages 836-842.
Crossref
Hon-Ming Ma, Yung-Chang Lu, Fang-Yuan Ho & Chun-Hsiung Huang. (2005) Long-Term Results of Total Condylar Knee Arthroplasty. The Journal of Arthroplasty 20:5, pages 580-584.
Crossref
A. LakdawalaS. TodoG. Scott. (2005) The significance of surface changes on retrieved femoral components after total knee replacement. The Journal of Bone and Joint Surgery. British volume 87-B:6, pages 796-799.
Crossref
Steven F Harwin. (2003) Complications of unicompartmental knee arthroplasty. Seminars in Arthroplasty 14:4, pages 232-244.
Crossref
Orhun K. Muratoglu, Charles R. Bragdon, Daniel O. O???Connor, Rebecca S. Perinchief, Murali Jasty & William H. Harris. (2002) Aggressive Wear Testing of a Cross-Linked Polyethylene in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research 404, pages 89-95.
Crossref
Pacharapol Udomkiat, Lawrence D. Dorr & William Long. (2001) Matched-pair analysis of all-polyethylene versus metal-backed tibial components. The Journal of Arthroplasty 16:6, pages 689-696.
Crossref
Yi-Sheng Chan, Ching-Jen Wang & Chun-Hsiung Shin. (2000) Two-stage operation for treatment of a large dissecting popliteal cyst after failed total knee arthroplasty. The Journal of Arthroplasty 15:8, pages 1068-1072.
Crossref
Markus S. Kuster, Sigrid Horz, Esther Spalinger, Gwidon W. Stachowiak & Andr?? G??chter. (2000) The Effects of Conformity and Load in Total Knee Replacement. Clinical Orthopaedics and Related Research 375, pages 302-312.
Crossref
John H Newman. (2000) Unicompartmental knee replacement. The Knee 7:2, pages 63-70.
Crossref
Leif Ryd, Ulrik Hansson, Gordon Blunn, Anders Lindstrand & Sören Toksvig‐Larsen. (2005) Failure of partial cementation to achieve implant stability and bone ingrowth: A long‐term roentgen stereophotogrammetric study of tibial components. Journal of Orthopaedic Research 17:3, pages 311-320.
Crossref
T M McGloughlin & J M Monaghan. (2016) Contact stress analysis of the tibial component of prosthetic knee implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 211:5, pages 391-399.
Crossref
I.D. Learmonth, J.G. Hussell & E.J. Smith. (1997) Inadequate polyethylene thickness and osteolysis in cementless hip arthroplasty. The Journal of Arthroplasty 12:3, pages 305-309.
Crossref
Willard L. Sauer, Kevin D. Weaver & Neil B. Beals. (1996) Fatigue performance of ultra-high-molecular-weight polyethylene: effect of gamma radiation sterilization. Biomaterials 17:20, pages 1929-1935.
Crossref
Søren Toksvig-Larsen, L. Ryd, A. Stentström, Finn Dansgård, Kjell Jonsson, Otto Robertson & A. Lindstrand. (1996) The porous-coated anatomic total knee experience. The Journal of Arthroplasty 11:1, pages 11-17.
Crossref
Jonathan L. Knight, Patricia A. Gorai, Richard D. Atwater & Louis Grothaus. (1995) Tibial polyethylene failure after primary porous-coated anatomic total knee arthroplasty. The Journal of Arthroplasty 10:6, pages 748-757.
Crossref
Douglas A Dennis. (1994) CEMENTED METAL-BACKED TIBIAL COMPONENTS. Orthopedics 17:9, pages 838-840.
Crossref
Thomas P. Schmalzried, Murali Jasty, Andrew Rosenberg & William H. Harris. (1994) Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. Journal of Applied Biomaterials 5:3, pages 185-190.
Crossref
John J. O’Connor & John W. Goodfellow. 1992. Biomechanics in Orthopedics. Biomechanics in Orthopedics 76 101 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.