485
Views
111
CrossRef citations to date
0
Altmetric
Original Article

Intermittent micromotion inhibits bone ingrowth

Titanium implants in rabbits

, , , &
Pages 141-145 | Accepted 31 Oct 1991, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (10)

Kjeld Søballe, Xinqian Chen, Thomas B Jensen, Louis Kidder & Joan E Bechtold. (2007) Alendronate treatment in the revision setting, with and without controlled implant motion. Acta Orthopaedica 78:6, pages 800-807.
Read now
Mikael Sundfeldt, Lars V Carlsson, Carina B Johansson, Peter Thomsen & Christina Gretzer. (2006) Aseptic loosening, not only a question of wear: A review of different theories. Acta Orthopaedica 77:2, pages 177-197.
Read now
Tian-Fang Li, Seppo Santavirta, Ismo Virtanen, Mauno Könönen, Michiaki Takagi & Yrjö T Konttinen. (1999) Increased expression of EMMPRIN in the tissue around loosened hip prostheses. Acta Orthopaedica Scandinavica 70:5, pages 446-451.
Read now
Per Aspenberg & Harm van der Vis. (1998) Fluid pressure may cause periprosthetic osteolysis: Particles are not the only thing. Acta Orthopaedica Scandinavica 69:1, pages 1-4.
Read now
Jian-Sheng Wang. (1996) Basic fibroblast growth factor for stimulation of bone formation in osteoinductive or conductive implants. Acta Orthopaedica Scandinavica 67:sup269, pages 1-33.
Read now
Per Aspenberg, Magnus Tagil, Carina Kristensson & Sven Lidin. (1996) Bone graft proteins influence osteoconduction: A titanium chamber study in rats. Acta Orthopaedica Scandinavica 67:4, pages 377-382.
Read now
Ingemar Önsten, Lennart Sanzén, Åke Carlsson & Jack Besjakov. (1995) Migration of uncemented, long-stem femoral components in revision hip arthroplasty:A 2-8 year clinical follow-up of 45 cases and radiostereometric analysis of 13 cases. Acta Orthopaedica Scandinavica 66:3, pages 220-224.
Read now
Sissel Torgersen, Nils Roar Gjerdet, Egil S. Erichsen & Gisle Bang. (1995) Metal particles and tissue changes adjacent to miniplates A retrieval study. Acta Odontologica Scandinavica 53:2, pages 65-71.
Read now
Kjeld Søballe. (1993) Hydroxyapatite ceramic coating for bone implant fixation. Acta Orthopaedica Scandinavica 64:sup255, pages 1-58.
Read now

Articles from other publishers (101)

Olivier Schottey, Stijn E.F. Huys, G. Harry van Lenthe, Maurice Y. Mommaerts & Jos Vander Sloten. (2023) Development of a topologically optimized patient-specific mandibular reconstruction implant for a Brown class II defect. Annals of 3D Printed Medicine 10, pages 100107.
Crossref
Ryota Watanabe, Hiroyuki Takahashi, Aira Matsugaki, Toru Uemukai, Yasumichi Kogai, Takashi Imagama, Kiminori Yukata, Takayoshi Nakano & Takashi Sakai. (2022) Novel nano‐hydroxyapatite coating of additively manufactured three‐dimensional porous implants improves bone ingrowth and initial fixation. Journal of Biomedical Materials Research Part B: Applied Biomaterials 111:2, pages 453-462.
Crossref
Nupur Kohli, Jennifer C. Stoddart & Richard J. van Arkel. (2021) The limit of tolerable micromotion for implant osseointegration: a systematic review. Scientific Reports 11:1.
Crossref
Nabil Mehta, Joseph Serino, Edward S. Hur, Shelby Smith, Kamran S. Hamid, Simon Lee & Daniel D. Bohl. (2020) Pathogenesis, Evaluation, and Management of Osteolysis Following Total Ankle Arthroplasty. Foot & Ankle International 42:2, pages 230-242.
Crossref
MAHDI QASEMI, M-MORAD SHEIKHI, MOJTABA ZOLFAGHARI & VAHID TAHMASBI. (2020) EXPERIMENTAL ANALYSIS, STATISTICAL MODELING AND OPTIMIZATION OF EFFECTIVE PARAMETERS ON SURFACE QUALITY IN CORTICAL BONE MILLING PROCESS. Journal of Mechanics in Medicine and Biology 20:04, pages 1950078.
Crossref
Nicholas A. Beckmann, Rudi G. Bitsch, Mareike Schonhoff, Klaus-Arno Siebenrock, Martin Schwarze & Sebastian Jaeger. (2020) Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs. Materials 13:7, pages 1783.
Crossref
MohammedInuwa Maitama, YauZakari Lawal, FridaySamuel Ejagwulu, AbubakarMohammed Kabir & LawalDahiru Ismaila. (2020) Challenges in primary hip arthroplasty for neglected post-traumatic hip dislocations with acetabular defect. Nigerian Journal of Orthopaedics and Trauma 19:2, pages 73.
Crossref
Sachin Khurana, Manish Khatri, Mansi Bansal, Mohd Rehan, Komal Puri, Rana Afreen & Ritika Narang. (2020) Clinical and esthetic outcome of immediate implant placed in postextraction site with alveolar bone defect using guided bone regeneration. International Journal of Preventive and Clinical Dental Research 7:3, pages 87.
Crossref
Vahid Tahmasbi, Mehdi Safari & Jalal Joudaki. (2019) Statistical modeling, Sobol sensitivity analysis and optimization of single-tip tool geometrical parameters in the cortical bone machining process. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 234:1, pages 28-38.
Crossref
Siddhartha Das, Kanchan Dholam, Sandeep Gurav, Kiran Bendale, Arvind Ingle, Bhabani Mohanty, Pradip Chaudhari & Jayesh R. Bellare. (2019) Accentuated osseointegration in osteogenic nanofibrous coated titanium implants. Scientific Reports 9:1.
Crossref
Benjamin A. McArthur, Ryan Scully, F. Patrick Ross, Mathias P. G. Bostrom & Anna Falghren. (2018) Mechanically Induced Periprosthetic Osteolysis: A Systematic Review. HSS Journal ® 15:3, pages 286-296.
Crossref
C. Nich & M. Hamadouche. (2018) Reacciones a los productos de degradación de los implantes articulares. EMC - Aparato Locomotor 51:4, pages 1-14.
Crossref
Roy D. Bloebaum, Nicole T. Abdo, Aaron A. Hofmann, Richard T. Epperson, Raymond E. Olsen & Ornusa Chalayon. (2018) Transcortical or intracondylar? Which model is accurate for predicting biomaterial attachment in total joint replacement?. Journal of Biomedical Materials Research Part B: Applied Biomaterials 106:2, pages 578-588.
Crossref
Hyun-Chang Lim, Daniel S. Thoma, Mijeong Jeon, Je-Seon Song, Sang-Kyou Lee & Ui-Won Jung. (2018) Effect of Hypoxia-Inducible Factor 1 α on Early Healing in Extraction Sockets . BioMed Research International 2018, pages 1-9.
Crossref
Mohit G. Kheur, Raman Sandhu, Supriya Kheur, Bach Le & Tabrez Lakha. (2016) Reliability of Resonance Frequency Analysis as an Indicator of Implant Micromotion. Implant Dentistry 25:6, pages 783-788.
Crossref
Yonathan Buks, Kirk L. Wendelburg, Susan M. Stover & Tanya C. Garcia‐Nolen. (2016) The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora. Veterinary Surgery 45:2, pages 155-164.
Crossref
H. M. Korani, D. J. Marcellin-Little & S. C. Roe. (2015) Variability associated with assessing changes in position of a canine uncemented femoral stem prosthesis. Veterinary and Comparative Orthopaedics and Traumatology 28:6, pages 409-416.
Crossref
Redmer van Wijngaarden, Laurens van der Plaat, Rebecca A. Nieuwe Weme, H. Cornelis Doets, Johan Westerga & Daniel Haverkamp. (2015) Etiopathogenesis of osteolytic cysts associated with total ankle arthroplasty, a histological study. Foot and Ankle Surgery 21:2, pages 132-136.
Crossref
Leandro Chambrone, Jamil Awad Shibli, Carlos Eduardo Mercúrio, Bruna Cardoso & Philip M. Preshaw. (2015) Efficacy of standard (SLA) and modified sandblasted and acid-etched (SLActive) dental implants in promoting immediate and/or early occlusal loading protocols: a systematic review of prospective studies. Clinical Oral Implants Research 26:4, pages 359-370.
Crossref
Adrien Michel, Romain Bosc, Romain Vayron & Guillaume Haiat. (2015) In Vitro Evaluation of the Acetabular Cup Primary Stability by Impact Analysis. Journal of Biomechanical Engineering 137:3.
Crossref
Nathan T. Evans, F. Brennan Torstrick, Christopher S.D. Lee, Kenneth M. Dupont, David L. Safranski, W. Allen Chang, Annie E. Macedo, Angela S.P. Lin, Jennifer M. Boothby, Daniel C. Whittingslow, Robert A. Carson, Robert E. Guldberg & Ken Gall. (2015) High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants. Acta Biomaterialia 13, pages 159-167.
Crossref
Troedhan Angelo, Wainwright Marcel, Kurrek Andreas & Schlichting Izabela. (2015) Biomechanical Stability of Dental Implants in Augmented Maxillary Sites: Results of a Randomized Clinical Study with Four Different Biomaterials and PRF and a Biological View on Guided Bone Regeneration. BioMed Research International 2015, pages 1-17.
Crossref
Géraldine Wolinne, Céline Harnisch, Eva Héripré, Sylvie Ruch, Armando Salito, Michel Jeandin & Laurent Corté. (2014) Mechanical Study of Novel VPS-Titanium Coating on Polyethylene Substrates. Journal of Thermal Spray Technology.
Crossref
ShihJye Tan, Josephine Y. Fang, Zhi Yang, Marcel E. Nimni & Bo Han. (2014) The synergetic effect of hydrogel stiffness and growth factor on osteogenic differentiation. Biomaterials 35:20, pages 5294-5306.
Crossref
Till Orla Klatte, Daniel Kendoff, Reza Sabihi, Atul F. Kamath, Johannes M. Rueger & Thorsten Gehrke. (2014) Tantalum Acetabular Augments in One-stage Exchange of Infected Total Hip Arthroplasty: A Case–control Study. The Journal of Arthroplasty 29:7, pages 1443-1448.
Crossref
Mayara B. Ferreira, Valentim A. Barão, Juliana A. Delben, Leonardo P. Faverani, Ana Carolina Hipólito & Wirley G. Assunção. (2014) Non-linear 3D finite element analysis of full-arch implant-supported fixed dentures. Materials Science and Engineering: C 38, pages 306-314.
Crossref
Nicholas A. Beckmann, Stefan Weiss, Matthias C.M. Klotz, Matthias Gondan, Sebastian Jaeger & Rudi G. Bitsch. (2014) Loosening After Acetabular Revision: Comparison of Trabecular Metal and Reinforcement Rings. A Systematic Review. The Journal of Arthroplasty 29:1, pages 229-235.
Crossref
Kris Gellynck, Rishma Shah, Mohammed Parkar, Anne Young, Paul Buxton & Peter Brett. (2013) Small molecule stimulation enhances bone regeneration but not titanium implant osseointegration. Bone 57:2, pages 405-412.
Crossref
Aaron J. Krych, Florian Wanivenhaus, Kenneth W. Ng, Stephen Doty, Russell F. Warren & Suzanne A. Maher. (2013) Matrix generation within a macroporous non-degradable implant for osteochondral defects is not enhanced with partial enzymatic digestion of the surrounding tissue: evaluation in an in vivo rabbit model. Journal of Materials Science: Materials in Medicine 24:10, pages 2429-2437.
Crossref
Thomas L. Bernasek, Naga Kiran Thatimatla, Melissa Levering & George J. Haidukewych. (2013) Effect of Immediate Full Weight Bearing on Abductor Repair and Clinical Function After THA Through a Modified Hardinge Approach. Orthopedics 36:3.
Crossref
J. Geringer, M.T. Mathew, M.A. Wimmer & D.D. Macdonald. 2013. Biomaterials and Medical Tribology. Biomaterials and Medical Tribology 133 180 .
Shan-Shan Gao, Ya-Rong Zhang, Zhuo-Li Zhu & Hai-Yang Yu. (2012) Micromotions and combined damages at the dental implant/bone interface. International Journal of Oral Science 4:4, pages 182-188.
Crossref
Jason P. Long, Scott J. Hollister & Steven A. Goldstein. (2012) A paradigm for the development and evaluation of novel implant topologies for bone fixation: In vivo evaluation. Journal of Biomechanics 45:15, pages 2651-2657.
Crossref
S. HEBERER, D. HILDEBRAND & K. NELSON. (2011) Survival rate and potential influential factors for two transitional implant systems in edentulous patients: a prospective clinical study. Journal of Oral Rehabilitation 38:6, pages 447-453.
Crossref
Kristen L. Helton, Buddy D. Ratner & Natalie A. Wisniewski. (2011) Biomechanics of the Sensor-Tissue Interface—Effects of Motion, Pressure, and Design on Sensor Performance and Foreign Body Response—Part II: Examples and Application. Journal of Diabetes Science and Technology 5:3, pages 647-656.
Crossref
Donok Choi, Yong-San Yoon & Deuksoo Hwang. (2011) Evaluation of sleeved implant fixation using a rat model. Medical Engineering & Physics 33:3, pages 310-314.
Crossref
Michel Nganbe, Usman Khan, Hakim Louati, Andrew Speirs & Paul E. Beaulé. (2011) In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements . Journal of Biomedical Materials Research Part B: Applied Biomaterials 97B:1, pages 132-138.
Crossref
Chih-Long Chen, Chih-Ling Chang & Shih-Jung Lin. (2011) Immediate implant placement and provisionalization with simultaneous guided bone regeneration in the esthetic zone. Journal of Dental Sciences 6:1, pages 53-60.
Crossref
Michel Nganbe, Hakim Louati, Usman Khan, Andrew Speirs & Paul E. Beaulé. (2010) Retrieval analysis and in vitro assessment of strength, durability, and distraction of a modular total hip replacement . Journal of Biomedical Materials Research Part A 95A:3, pages 819-827.
Crossref
Leandro Chambrone, Luiz A. Chambrone & Luiz A. Lima. (2010) Effects of Occlusal Overload on Peri-Implant Tissue Health: A Systematic Review of Animal-Model Studies. Journal of Periodontology 81:10, pages 1367-1378.
Crossref
David A.J. Wilson, Janie L. Astephen, Allan W. Hennigar & Michael J. Dunbar. (2010) Inducible Displacement of a Trabecular Metal Tibial Monoblock Component. The Journal of Arthroplasty 25:6, pages 893-900.
Crossref
Daniel Rodrigo, Luis Aracil, Conchita Martin & Mariano Sanz. (2010) Diagnosis of implant stability and its impact on implant survival: a prospective case series study. Clinical Oral Implants Research 21:3, pages 255-261.
Crossref
Naomitsu Hamada. (2010) A Case Report of a Dental Implant using a Modified Free-end Saddle-bridge as a Provisional Prosthesis. Annals of Japan Prosthodontic Society 2:2, pages 118-121.
Crossref
Marjolein C. H. van der Meulen, Xu Yang, Timothy G. Morgan & Mathias P. G. Bostrom. (2009) The Effects of Loading on Cancellous Bone in the Rabbit. Clinical Orthopaedics & Related Research 467:8, pages 2000-2006.
Crossref
Kenneth A. Mann, Mark A. Miller, Amos Race & Nico Verdonschot. (2009) Shear fatigue micromechanics of the cement–bone interface: An in vitro study using digital image correlation techniques. Journal of Orthopaedic Research 27:3, pages 340-346.
Crossref
V.A. Stadelamann, A. Terrier & D.-P. Pioletti. (2009) Osteoclastogenesis can be mechanically-induced in the peri-implant bone. IRBM 30:1, pages 10-13.
Crossref
Sara Checa & Patrick J. Prendergast. (2008) A Mechanobiological Model for Tissue Differentiation that Includes Angiogenesis: A Lattice-Based Modeling Approach. Annals of Biomedical Engineering 37:1, pages 129-145.
Crossref
Anke Bernstein, Doreen Nöbel, Hermann O. Mayr, Felix Göbel, Georg Berger, Ute Ploska, Renate Gildenhaar & Jörg Brandt. (2008) Inhibition of mineralization by a calcium zirconium phosphate coating. Journal of Biomedical Materials Research Part B: Applied Biomaterials 86B:2, pages 422-429.
Crossref
Anke Bernstein, Doreen Nöbel, Hermann O. Mayr, Renate Gildenhaar, Georg BergerUte PloskaJoerg Brandt. (2007) Influence of Calcium Zirconium Phosphate Containing Coatings on Mineralization of Bone. Key Engineering Materials 361-363, pages 641-644.
Crossref
Luiz Meirelles, Anna Arvidsson, Tomas Albrektsson & Ann Wennerberg. (2007) Increased bone formation to unstable nano rough titanium implants. Clinical Oral Implants Research 18:3, pages 326-332.
Crossref
Paul A. Clark, Andrew M. Clark, Anthony Rodriguez, Mohammad A. Hussain & Jeremy J. Mao. (2007) Nanoscale characterization of bone–implant interface and biomechanical modulation of bone ingrowth. Materials Science and Engineering: C 27:3, pages 382-393.
Crossref
Katleen Vandamme, Ignace Naert, Liesbet Geris, Jozef Vander Sloten, Robert Puers & Joke Duyck. (2007) The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit. European Journal of Oral Sciences 115:1, pages 21-29.
Crossref
M. Lewandowska-Szumieł, K. Sikorski, A. Szummer, Z. Lewandowski & W. Marczyński. (2007) Osteoblast response to the elastic strain of metallic support. Journal of Biomechanics 40:3, pages 554-560.
Crossref
D. B. HERREN, S. SCHINDELE, J. GOLDHAHN & B. R. SIMMEN. (2016) Problematic Bone Fixation with Pyrocarbon Implants in Proximal Interphalangeal Joint Replacement: Short-Term Results. Journal of Hand Surgery 31:6, pages 643-651.
Crossref
J. Goldhahn, D. Neuhoff, S. Schaeren, B. Steiner, B. Linke, M. Aebi & E. Schneider. (2006) Osseointegration of hollow cylinder based spinal implants in normal and osteoporotic vertebrae: a sheep study. Archives of Orthopaedic and Trauma Surgery 126:8, pages 554-561.
Crossref
Per Aspenberg. 2005. Joint Replacement and Bone Resorption. Joint Replacement and Bone Resorption 399 411 .
Jae-Hoon Lee, Val Frias & Keun-woo Lee. (2005) Use of an Immediate Provisional Implant to Support a Full-Arch Interim Restoration: A Clinical Report. Journal of Prosthodontics 14:2, pages 127-130.
Crossref
A S Wong, A M R New, G Isaacs & M Taylor. (2006) Effect of Bone Material Properties on the Initial Stability of a Cementless Hip Stem: A Finite Element Study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 219:4, pages 265-275.
Crossref
Małgorzata Lewandowska‐Szumieł, Krzysztof Sikorski, Andrzej Szummer, Janusz Komender, Marcin Kowalski & A. U. Daniels. (2004) Experimental model for observation of micromotion in cell culture. Journal of Biomedical Materials Research Part B: Applied Biomaterials 72B:2, pages 379-387.
Crossref
R. G�nther, L. Morawietz, T. Gehrke, L. Frommelt, C. Kaps & V. Krenn. (2005) Inflammatorische Reaktion bei abriebinduzierter und infekti�ser Lockerung von H�ft- und KnieendoprothesenInflammatory reactions in the wear particle induced and infectious periprosthetic membrane of loosened hip- and knee endoprostheses: pathogenetic relevance of differentially expressed genes cd9, cd11b, cd18, cd52 and pdgfr?. Der Orthop�de 34:1, pages 55-64.
Crossref
Joke Duyck, Michel De Cooman, Robert Puers, Hans Van Oosterwyck, Jos Vander Sloten & Ignace Naert. (2004) A repeated sampling bone chamber methodology for the evaluation of tissue differentiation and bone adaptation around titanium implants under controlled mechanical conditions. Journal of Biomechanics 37:12, pages 1819-1822.
Crossref
H.E Götz, M Müller, A Emmel, U Holzwarth, R.G Erben & R Stangl. (2004) Effect of surface finish on the osseointegration of laser-treated titanium alloy implants. Biomaterials 25:18, pages 4057-4064.
Crossref
E.M. Ooms, N. Verdonschot, J.G.C. Wolke, W.Van de Wijdeven, M.M.M. Willems, M.F.T. Schoenmaker & J.A. Jansen. (2004) Enhancement of initial stability of press-fit femoral stems using injectable calcium phosphate cement: an in vitro study in dog bones. Biomaterials 25:17, pages 3887-3894.
Crossref
Periklis Proussaefs & Jaime Lozada. (2004) Immediate loading of hydroxyapatite-coated implants in the maxillary premolar area: Three-year results of a pilot study. The Journal of Prosthetic Dentistry 91:3, pages 228-233.
Crossref
M. Mullender, A. J. El Haj, Y. Yang, M. A. van Duin, E. H. Burger & J. Klein-Nulend. (2004) Mechanotransduction of bone cellsin vitro: Mechanobiology of bone tissue. Medical and Biological Engineering and Computing 42:1, pages 14-21.
Crossref
Jean-Alain Epinette & Michael T. ManleyOle Rahbek, Søren Overgaard & Kjeld Søballe. 2004. Fifteen Years of Clinical Experience with Hydroxyapatite Coatings in Joint Arthroplasty. Fifteen Years of Clinical Experience with Hydroxyapatite Coatings in Joint Arthroplasty 35 51 .
Ricardo Gapski, Hom-Lay Wang, Paulo Mascarenhas & Niklaus P. Lang. (2003) Critical review of immediate implant loading. Clinical Oral Implants Research 14:5, pages 515-527.
Crossref
David Leshem, Ziv Mazor, Roy Leshem & Daren Rosen. (2003) A Simple Technique for Fabrication of Immediate Interim Removable Prosthesis Supported by Transitional Implants. Implant Dentistry 12:3, pages 227-231.
Crossref
Adriano Piattelli, Antonio Scarano, Lorenzo Favero, Giovanna Iezzi, Giovanna Petrone & Gian Antonio Favero. (2003) Clinical and Histologic Aspects of Dental Implants Removed Due to Mobility. Journal of Periodontology 74:3, pages 385-390.
Crossref
Greg Kammeyer, Periklis Proussaefs & Jaime Lozada. (2002) Conversion of a complete denture to a provisional implant-supported, screw-retained fixed prosthesis for immediate loading of a completely edentulous arch. The Journal of Prosthetic Dentistry 87:5, pages 473-476.
Crossref
Kitichai Rungcharassaeng, Jaime L. Lozada, Joseph Y.K. Kan, Jay S. Kim, Wayne V. Campagni & Carlos A. Munoz. (2002) Peri-implant tissue response of immediately loaded, threaded, HA-coated implants: 1-year results. The Journal of Prosthetic Dentistry 87:2, pages 173-181.
Crossref
R.Theodore FieldsJrJr & Larry M. Wolford. (2001) The osseointegration of Mitek mini anchors in the mandibular condyle. Journal of Oral and Maxillofacial Surgery 59:12, pages 1402-1406.
Crossref
Robert L. Vonau, Mathias P. G. Bostrom, Per Aspenberg & Andrew E. Sams. (2001) Combination of Growth Factors Inhibits Bone Ingrowth in the Bone Harvest Chamber. Clinical Orthopaedics and Related Research 386, pages 243-251.
Crossref
Periklis Proussaefs & Jaime Lozada. (2001) Immediate loading of single root form implants with the use of a custom acrylic stent. The Journal of Prosthetic Dentistry 85:4, pages 382-385.
Crossref
D.E.T Shepherd, J.C Leahy, D.W.L Hukins & D Wardlaw. (2001) Slippage of a spinous process hook during flexion in a flexible fixation system for the lumbar spine. Medical Engineering & Physics 23:2, pages 135-141.
Crossref
Marco Esposito, Peter Thomsen, Lars E. Ericson, Lars Sennerby & Ulf Lekholm. (2007) Histopathologic Observations on Late Oral Implant Failures. Clinical Implant Dentistry and Related Research 2:1, pages 18-32.
Crossref
S??ren Toksvig-Larsen, Lars Peter Jorn, Leif Ryd & Anders Lindstrand. (2000) Hydroxyapatite-Enhanced Tibial Prosthetic Fixation. Clinical Orthopaedics and Related Research 370, pages 192-200.
Crossref
Leif Ryd, Ulrik Hansson, Gordon Blunn, Anders Lindstrand & Sören Toksvig‐Larsen. (2005) Failure of partial cementation to achieve implant stability and bone ingrowth: A long‐term roentgen stereophotogrammetric study of tibial components. Journal of Orthopaedic Research 17:3, pages 311-320.
Crossref
Harm M. Van Der Visa, Per Aspenberg, Wikky Tigchelaar & Cornelis J.F. Van Noorden. (1999) Mechanical compression of a fibrous membrane surrounding bone causes bone resorption. Acta Histochemica 101:2, pages 203-212.
Crossref
Koichi Ito, Koichi Nanba & Seidai Murai. (1998) Effects of Bioabsorbable and Non-Resorbable Barrier Membranes on Bone Augmentation in Rabbit Calvaria. Journal of Periodontology 69:11, pages 1229-1237.
Crossref
Per Aspenberg & Harm Van der Vis. (1998) Migration, Particles, and Fluid Pressure. Clinical Orthopaedics and Related Research 352, pages 75???80.
Crossref
George L. Pal, Alastair Stevenson, Iven J. Klineberg, Martin Pearson, Tomas Albrektsson & Carina Johansson. (2013) A volumetric study of guided bone regeneration around titanium implants in the New Zealand white rabbit. Australian Dental Journal 43:2, pages 73-80.
Crossref
Balaji S. Ramamurti, Tracy E. Orr, Charles R. Bragdon, Jay D. Lowenstein, Murali Jasty & William H. Harris. (1997) Factors influencing stability at the interface between a porous surface and cancellous bone: A finite element analysis of a caninein vivo micromotion experiment. Journal of Biomedical Materials Research 36:2, pages 274-280.
Crossref
J. A. M. Clemens, C. P. A. T. Klein, R. J. B. Sakkers, W. J. A. Dhert, K. de Groot & P. M. Rozing. (1997) Healing of gaps around calcium phosphate-coated implants in trabecular bone of the goat. Journal of Biomedical Materials Research 36:1, pages 55-64.
Crossref
K. Kieswetter, Z. Schwartz, D.D. Dean & B.D. Boyan. (2016) The Role of Implant Surface Characteristics in the Healing of Bone. Critical Reviews in Oral Biology & Medicine 7:4, pages 329-345.
Crossref
Per Aspenberg, Stuart B. Goodman & Jian-Sheng Wang. (1996) Influence of Callus Deformation Time Bone Chamber Study in Rabbits. Clinical Orthopaedics and Related Research 322, pages 253???261.
Crossref
Per Aspenberg. 1996. Orthopaedic Allograft Surgery. Orthopaedic Allograft Surgery 53 60 .
Kjeld Søballe & Richard J. Friedman. 1996. Human Biomaterials Applications. Human Biomaterials Applications 137 167 .
J E Feighan, V M Goldberg, D Davy, J A Parr & S Stevenson. (1995) The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model.. The Journal of Bone & Joint Surgery 77:9, pages 1380-1395.
Crossref
Stuart B. Goodman, Per Aspenberg, Yong Song, Donald Regula & Lars Lidgren. (2004) Intermittent micromotion and polyethylene particles inhibit bone ingrowth into titanium chambers in rabbits. Journal of Applied Biomaterials 6:3, pages 161-165.
Crossref
S. Torgersen, G. Moe & R. Jonsson. (2007) Immunocompetent cells adjacent to stainless steel and titanium miniplates and screws. European Journal of Oral Sciences 103:1, pages 46-54.
Crossref
J. Pajam�ki, S. Lindholm, �. Andersson, K. Karlson, A. Yli-Urpo & R. -P. Happonen. (1995) Glass-ceramic-coated titanium hip endoprosthesis. Archives of Orthopaedic and Trauma Surgery 114:2, pages 119-122.
Crossref
Stuart B. Goodman, Yong Song, Amol Doshi & Per Aspenberg. (1994) Cessation of strain facilitates bone formation in the micromotion chamber implanted in the rabbit tibia. Biomaterials 15:11, pages 889-893.
Crossref
Stuart Goodman, Per Aspenberg, Yong Song, Donald RegulaJr.Jr., Amol Doshi & Lars Lidgren. (2004) Effects of intermittent micromotion versus polymer particles on tissue ingrowth: Experiment using a micromotion chamber implanted in rabbits. Journal of Applied Biomaterials 5:2, pages 117-123.
Crossref
I Onsten, A S Carlsson, A Ohlin & J A Nilsson. (1994) Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using roentgenstereophotogrammetric analysis.. The Journal of Bone & Joint Surgery 76:2, pages 185-194.
Crossref
Stuart Goodman, Jian-Sheng Wang, Amol Doshi & Per Aspenberg. (1993) Difference in bone ingrowth after one versus two daily episodes of micromotion: Experiments with titanium chambers in rabbits. Journal of Biomedical Materials Research 27:11, pages 1419-1424.
Crossref
Stuart Goodman, Søren Toksvig‐Larsen & Per Aspenberg. (2004) Ingrowth of bone into pores in titanium chambers implanted in rabbits: Effect of pore cross‐sectional shape in the presence of dynamic shear. Journal of Biomedical Materials Research 27:2, pages 247-253.
Crossref
Stuart Goodman & Per Aspenberg. (1993) Effects of mechanical stimulation on the differentiation of hard tissues. Biomaterials 14:8, pages 563-569.
Crossref
Leif Ryd & Sören Toksvig‐Larsen. (2005) Early postoperative fixation of tibial components: An in vivo roentgen stereophotogrammetric analysis. Journal of Orthopaedic Research 11:1, pages 142-148.
Crossref
Stuart Goodman & Per Aspenberg. (1992) Effect of amplitude of micromotion on bone ingrowth into titanium chambers implanted in the rabbit tibia. Biomaterials 13:13, pages 944-948.
Crossref
Olivier Schottey, Stijn E.F. Huys, Harry van Lenthe, Maurice Y. Mommaerts & Jos Vander Sloten. (2022) Development of a Topologically Optimized 3D-Printed Patient-Specific Mandibular Reconstruction Implant for a Brown Class II Defect. SSRN Electronic Journal.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.