182
Views
18
CrossRef citations to date
0
Altmetric
Original Articles

Ligandless dispersive solid phase extraction of cobalt ion using magnetic graphene oxide as an adsorbent followed by its determination with electrothermal atomic absorption spectrometry

, &
Pages 17-34 | Received 16 Jun 2019, Accepted 16 Aug 2019, Published online: 01 Oct 2019
 

ABSTRACT

Ligandless dispersive solid phase extraction technique was used for preconcentration of cobalt ion (Co2+) followed by its determination using electrothermal atomic absorption spectrometry (ETAAS). Graphene oxide (GO) was synthesised from graphite by the Hummer method and chemically magnetised to synthesise of the magnetic graphene oxide (MGO). The synthesised MGO was characterised by the Fourier transform-infrared spectrophotometry (FT-IR), vibrating sample magnetometer (VSM), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) and then used as an adsorbent for solid phase extraction of Co2+. The main parameters affecting the extraction recovery of Co2+ including pH of sample solution, amounts of adsorbent, extraction time and type and concentration of desorption solvent were investigated and optimised. The calibration curve was plotted in the range of 0.08–1.2 µg L−1 Co2+ with a correlation coefficient of 0.9987. The intra-day precision based on six replicate analysis of 0.2 µg L−1 Co2+ was 3.8% and the limit of detection (LOD) was 0.023 µg L−1 Co2+ (n = 5). Also, the adsorption isotherms and adsorption kinetics were investigated and based on the obtained results, the adsorption of Co2+ onto the MGO nanocomposite followed by both Langmuir and Freundlich isotherms with a maximum adsorption capacity of 114.9 mg g−1 Co2+. The results of kinetic models also show that the adsorption of Co2+ followed by the pseudo second order kinetic model. The accuracy of the proposed method was successfully checked by the analysis of two certified reference materials including certified reference material-trace metals in drinking water (CRM-TMDW) and spinach leaves 1570a samples (Student t-test with 95% confidence limit, n = 5). Finally, the proposed rapid and efficient solid phase extraction technique was used for the determination of trace levels of Co2+ in the human saliva, urine and different real samples.

Acknowledgments

The authors wish to thank the University of Neyshabur for supporting of this project.

Disclosure statement

No potential conflict of interest was reported by the authors.

Additional information

Funding

This work was supported by the university of neyshabur [14205].

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,223.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.