148
Views
5
CrossRef citations to date
0
Altmetric
Research Articles

Development and greenness assessment of a stability-indicating HPLC-DAD method for simultaneous determination of allopurinol and benzbromarone

, , &
Pages 887-896 | Received 12 Jan 2021, Accepted 24 Mar 2021, Published online: 25 Jun 2021
 

Abstract

The growing interest in Green Analytical Chemistry (GAC) principles through the replacement of polluting analytical procedures with greener ones, has encouraged us to develop an eco-friendly stability-indicating HPLC with diode array detection method (HPLC-DAD) for simultaneous determination of allopurinol (ALP) and benzbromarone (BNZ). Effective separation was accomplished using Durashell C18 column (4.6 × 250 mm, 5 µm particle size) with gradient elution of the mobile phase composed of 0.02 M ammonium acetate (pH 5.0) and methanol. Quantification of ALP and BNZ was based on measuring their peak areas at 251 nm. ALP and BNZ peaks eluted at retention times 4.85 and 10.30 min respectively. The proposed HPLC procedure was carefully validated in terms of system suitability, linearity, ranges, precision, accuracy, specificity, robustness, detection, and quantification limits. The linearity range for both ALP and BNZ was 5–100 µg/mL with correlation coefficients >0.9999. Forced degradation conditions of neutral, acidic, and alkaline hydrolysis, oxidation, and thermal degradation were applied on both drugs. Good resolution of the drugs from their forced degradation products proved that the proposed method is stability-indicating. In addition, the resolution of both drugs from about 10 pharmacologically or chemically related pharmaceutical compounds of different medicinal categories showed the high specificity of the proposed method. The validated HPLC method was successfully applied to the simultaneous determination of both drugs in their tablet dosage forms. Furthermore, greenness assessment and comparison with previously published methods were carried out using two different GAC metrics, namely, the national environmental method index (NEMI) and the analytical Eco-Scale.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,085.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.