252
Views
0
CrossRef citations to date
0
Altmetric
Review

Efficacy of Soft Contact Lenses for Myopia Control: A Systematic Review

, & ORCID Icon
Pages 185-192 | Received 20 Jul 2023, Accepted 25 Sep 2023, Published online: 18 Oct 2023
 

ABSTRACT

Purpose

To summarize and analyze critically the scientific evidence focused on the effectiveness of the use of hydrophilic contact lenses (HCLs) in myopia control, as well as their impact on visual quality and the involvement on the accommodative and binocular function.

Methods

This systematic review was developed selecting all original studies which evaluated HCLs for myopia control with follow-up of at least 1 year. Eligible randomized controlled trials (RCTs) were retrieved from PubMed MEDLINE and Scopus. Methodological quality of the studies was assessed using the Critical Appraisal Skills Programme (CASP) for RCTs.

Results

The search provided a total of 276 articles, selecting 13 according to the inclusion and exclusion criteria. The majority of studies evaluating the effectiveness of HCL showed a good efficacy in myopia progression, providing a good quality of vision. The quality of these studies was found to be suitable according to the CASP tool. The accommodative and binocular function with these lenses was evaluated in few studies, reporting a trend to an increase in the accommodative response and exophoria in near vision, while maintaining good level of stereopsis. Aberrometry and pupillometry were only studied in one trial, in which the authors did not find changes in these variables after the use of a myopia control HCL.

Conclusions

There is a strong evidence about the effectiveness of different HCLs designs for slowing down myopia progression in children, providing all of them good levels of visual quality. However, there is still poor evidence about changes in accommodation and binocular function, as well as in pupil size and aberrometry with myopia control HCLs, being necessary more studies focused on this issue.

Disclosure statement

The authors have no proprietary or commercial interest in the medical devices that are involved in this manuscript.

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 530.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.