200
Views
2
CrossRef citations to date
0
Altmetric
Articles

Streamlined stationary phase selection facilitated by a “sample-plug retention test” in supercritical fluid extraction-supercritical fluid chromatography-mass spectroscopy (SFE-SFC-MS) method development for on-line extraction of anabolic agents

ORCID Icon, , ORCID Icon, , , & ORCID Icon show all
Pages 842-861 | Published online: 20 Jul 2022
 

Abstract

A novel method development (MD) approach was established to aid column selection for online supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry (SFE-SFC-MS). An adapted stationary phase (SP) selection procedure was used to expand traditional SFC-MS screening by inclusion of an “Analyte-Plug Retention Test.” This test enabled an early evaluation of “trapping” capability for a plug of targeted analytes on the SP. Using an SFE-simulation method, the on-line trapping of an SFE-based extract-plug was mimicked by trapping an SFC-based injection-plug under instrument conditions similar to an actual on-line extraction. Thirteen SPs were screened using the adapted MD procedure as part of the SFC-separation optimization in the development of an on-line SFE-SFC-MS extraction method for anabolic agents (AAS) in anti-doping testing. A cyano SP was chosen for further development, based on chromatographic separation potential and high plug-retention potential for targeted analytes. The chosen column was used in “proof-of-concept” on-line extractions using a generic SFE-SFC-MS method. Successful extract-plug trapping was demonstrated. Retention times and peak areas (4–20%RSD) were reproducible for targeted AAS. Successful first round SFE-SFC-MS SP selection was demonstrated to circumvent tedious re-optimization in future development stages and streamlining of the hyphenated SFE-SFC-MS MD process.

Graphical Abstract

Acknowledgments

The authors acknowledge Shimadzu Scientific Instruments, Inc. for instrumentation and research support for this work. We would also like to acknowledge the support from Restek Corporation, in the form of chromatography columns and stationary phases used during this work. We offer this study in honor of and in remembrance to Professor Harold McNair, a wonderful teacher, researcher, mentor, friend, and human being.

Disclosure statement

The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: YF, WH, and MN are employed by Shimadzu Corporation or Shimadzu Scientific Instruments, Inc., the manufacturer of the instrumentation utilized in this work.

Additional information

Funding

Further support is acknowledged from the National Science Foundation [CHE-2108767].

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 583.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.