Abstract

Introduction

Inferior vena cava (IVC) diameter decreases under conditions of hypovolemia. Point-of-care ultrasound (POCUS) may be useful to emergently assess IVC diameter. This study tested the hypothesis that ultrasound measurements of IVC diameter decreases during severe simulated blood loss.

Methods

Blood loss was simulated in 14 healthy men (22 ± 2 years) using lower body negative pressure (LBNP). Pressure within the LBNP chamber was reduced 10 mmHg of LBNP every four minutes until participants experienced pre-syncopal symptoms or until 80 mmHg of LBNP was completed. IVC diameter was imaged with POCUS using B-mode in the long and short axis views between minutes two and four of each stage.

Results

Maximum IVC diameter in the long axis view was lower than baseline (1.5 ± 0.4 cm) starting at -20 mmHg of LBNP (1.0 ± 0.3 cm; p < 0.01) and throughout LBNP (p < 0.01). The minimum IVC diameter in the long axis view was lower than baseline (0.9 ± 0.3 cm) at -20 mmHg of LBNP (0.5 ± 0.3 cm; p < 0.01) and throughout LBNP (p < 0.01). Maximum IVC diameter in the short axis view was lower than baseline (0.9 ± 0.2 cm) at 40 mmHg of LBNP (0.6 ± 0.2; p = 0.01) and the final LBNP stage (0.6 ± 0.2 cm; p < 0.01). IVC minimum diameter in the short axis view was lower than baseline (0.5 ± 0.2 cm) at the final LBNP stage (0.3 ± 0.2 cm; p = 0.01).

Conclusion

These data demonstrate that IVC diameter decreases prior to changes in traditional vital signs during simulated blood loss. Further study is needed to determine the view and diameter threshold that most accurate for identifying hemorrhage requiring emergent intervention.

Additional information

Funding

This work ws supported by National Center for Advancing Translational Sciences; National Heart, Lung, and Blood Institute.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 85.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.