454
Views
15
CrossRef citations to date
0
Altmetric
Original Article

Accuracy of sonographic estimated fetal weight in suspected macrosomia: the likelihood of overestimating and underestimating the true birthweight

ORCID Icon, & ORCID Icon
Pages 967-972 | Received 04 Jun 2018, Accepted 10 Aug 2018, Published online: 03 Sep 2018
 

Abstract

Objective: Macrosomia has increased risk of serious adverse outcomes for both infants and their mothers. As such, many providers recommend induction of labor or cesarean delivery (CD) based on sonographic estimated fetal weight (sonoEFW) cutoffs. It is known that sonoEFW is a poor predictor of birthweight (BW), especially at the extremes of weight. It is not clear, however, whether sonoEFWs tend to underestimate or overestimate the true BW among fetuses with suspected macrosomia. The objective of this study was to compare rates of overestimation of BW among women with suspected macrosomia by sonoEFW.

Methods: This was a retrospective cohort study of women who presented to a single maternal–fetal medicine ultrasound unit within 2 weeks prior to delivery from January 2011 to November 2017. We identified women who received a sonoEFW ≥4000 g. The study sample was divided into four sonoEFW categories: 4000–4249, 4250–4499, 4500–4749, and ≥4750 g. Accuracy of sonoEFW was compared across groups, with the primary outcome being overestimation of BW.

Results: A total of 502 patients were included, of whom 301 (60.1%) had a sonoEFW 4000–4249 g, 135 (26.9%) had a sonoEFW 4250–4499 g, 45 (9.0%) had a sonoEFW 4500–4749 g, and 21 (4.2%) had a sonoEFW ≥4750 g. In each sonoEFW group, the risk of overestimating BW was greater than 50%, and the likelihood of overestimation of BW increased significantly across sonoEFW groups (69.4, 76.3, 80.0, 95.2%, p < .001). This held true after adjusting for differences in baseline characteristics, including diabetes and amniotic fluid index. BW ≥4500 g was not accurately predicted. Among women with sonoEFW 4500–4749 g, only 28.9% delivered a neonate with a BW >4500 g; for women with a sonoEFW ≥4750 g, only 47.6% had a BW >4500 g. One hundred sixty-one (32.1%) women underwent CD for suspected macrosomia. Of these CDs, 48 (29.8%) of neonates had a BW <4000 g and 134 (83.2%) had a BW <4500 g.

Conclusion: In patients undergoing sonoEFW within 2 weeks of delivery, sonoEFWs ≥4000 g are significantly more likely to overestimate than underestimate the true BW. Obstetricians should be cautious about intervening based on sonoEFW alone, given the high risk that this value is an overestimation of the true weight.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.