Preliminary results analysis for left ventricular systolic function in normal fetuses by automated cardiac motion quantitation

, , , , &
Pages 2701-2709 | Received 09 Aug 2019, Accepted 18 Sep 2019, Published online: 10 Oct 2019
 

Abstract

Background

Fetal heart evaluation has been proven to have the utility in the differential diagnosis of cardiomyopathies or prediction of perinatal mortality in congenital heart disease. The purpose of this study is to introduce a novel method that can measure the global and regional longitudinal strain of left ventricle in fetuses, described as automated cardiac motion quantitation (aCMQ). Furthermore, to evaluate the feasibility and value of aCMQ.

Methods

A cross-sectional study was conducted in 138 fetuses with normal heart structure, then were divided into four groups by gestational age, standard four-chamber view clips were collected, the global and segmental longitudinal peak systolic strain of the left ventricle were measured by aCMQ, interobserver and intraobserver variability was analyzed.

Results

The success rate of aCMQ analysis was 90.6% (125/138). aCMQ can obtain more comprehensive data to evaluate fetal cardiac function by on-line analysis, including the left ventricular end-systolic volume (LVESV, 0.64 ± 0.16 ml), the left ventricular end-diastolic volume (LVEDV, 0.85 ± 0.35 ml), strain and so on. There was no significant correlation between the gestational age and the global and segmental longitudinal peak strain of the left ventricle (all p > .05). The base and middle segmental strain values of left ventricular free wall were similar to those of the interventricular septum. No significant differences were found in base segments and middle segments for left ventricular free wall (LVLW) and the interventricular septum (IVS) (p > .05). The strain of the apex segment was higher than that of the base and middle segment (p < .05), and there were significant differences between the apex and the base and the middle (p < .05). Interobserver and intraobserver variability showed a small bias among the observers.

Conclusions

The global and regional strain values of fetus have no correlation with gestational ages, and the strain values of apical segment are higher than those of basal and middle segments. The base and middle segmental strain values of left ventricular free wall were similar to those of the interventricular septum. aCMQ is a novel method of two dimensional speckle tracking echocardiography to assess the global and regional systolic function of fetuses. It’s a feasible and reproducible approach to evaluate normal cardiac function of fetus quantitatively and may have potential in fetuses with congenital heart diseases.

Disclosure statement

No potential conflict of interest was reported by the authors.

A data availability statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.