Deformation patterns in WorldSID 50th percentile dummy instrumented with IR-TRACC and RibEye™ in different loading configurations

, &
Pages 515-520 | Received 20 Apr 2018, Accepted 29 Apr 2019, Published online: 10 Jun 2019
 

Abstract

Objective: The purpose of this study was to investigate the effect of different loading configurations on the WorldSID 50th percentile male dummy instrumented either with the Infra-Red Telescoping Rod for the Assessment of Chest Compression (IR-TRACC) or the RibEye™ rib deflection measurement system.

Methods: The optical sensors of the RibEye system were used to capture the multipoint deformation of the dummy at frontal and rearward off-center locations in addition to the center of the rib location. The experimental setup consisted of 2 types of loadings: Low severity and high severity. Low-severity loading was performed by deploying a fixture-mounted side airbag on the dummy and high-severity loading was achieved by deploying a driver front airbag mounted in a similar fashion. The low-severity condition aimed at deforming the dummy’s ribs locally at off-center locations where the RibEye light emitting diodes (LEDs) were positioned to capture the deformations at those locations. The high-severity condition aimed at loading the dummy at high speed in lateral and oblique directions similar to what is experienced by dummies in side impacts.

Results: In the low-severity tests, the peak deflections, in terms of length change, were approximately 15–20 mm, whereas for the high-severity cases the peak deflections were in the range of 30–40 mm for both IR-TRACC and RibEye cases.

Conclusions: For similar physical insults, dummies with the IR-TRACC and RibEye systems showed varying results for both length changes and the shoulder forces depending on the severity and direction of loading. Under purely lateral loading, the mid-length changes with the RibEye and the 1D IR-TRACC were comparable. In the oblique loading conditions, more differences were seen with the 2 systems depending on the impact direction. The shoulder forces consistently differed between the 2 systems. In the frontal oblique low-severity cases, the ribs pivoted along the spine end and the length change was not found to be a suitable parameter to quantify rib deformation in such loading scenarios.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 331.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.