Abstract

Introduction: This case of Loperamide misuse had refractory ventricular arrhythmias and was successfully supported by VA ECMO. Loperamide is currently available without prescription and can be obtained in large quantities over the internet despite Food and Drug Administration (FDA) 2016 black box warning noting cardiac toxicity. This case illustrates the life-threatening toxicity of loperamide and suggests a supportive modality to provide clinical time while the drug is cleared endogenously or exogenously.

Case report: A 36-year-old female was found minimally responsive. Vital signs and monitoring revealed wide complex bradycardia, undetectable blood pressure, hypothermia, bradypnea, and hypoglycemia. The rhythm degenerated to polymorphic ventricular tachycardia cardia refractory to multiple ACLS protocols. VA-ECMO was initiated with immediate stabilization. Subsequent history revealed massive consumption of loperamide taking 400–600 mg daily. Highest known loperamide and N-desmethyl-loperamide levels were 32 and 500 ng/ml respectively. Since loperamide and metabolites are known to be protein bound, molecular adsorbent recirculating system (MARS) was initiated for toxin clearance. Additionally, she developed acute renal failure supported by CRRT. She was ultimately weaned from ECMO, MARS, and CRRT and discharged neurologically intact on hospital day 12.

Discussion: VA ECMO for hemodynamic support provided the needed time for natural resolution of the cardiac toxicity while providing adequate perfusion. MARS was used in the setting of highly protein bound toxins, but drug clearance could not be demonstrated through serial levels. VA ECMO (or referral to a center with VA ECMO) should be considered with lethal loperamide-induced cardiotoxicity and perhaps other cardio-toxins.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,501.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.