164
Views
7
CrossRef citations to date
0
Altmetric
Research Article

Impact of building integrated photovoltaic-phase change material panels on building energy efficiency improvement: a case study

ORCID Icon, &
Pages 7453-7482 | Received 13 Jun 2022, Accepted 02 Aug 2022, Published online: 21 Aug 2022
 

ABSTRACT

Integrating phase change material with building envelopes is recently considered one of the most reliable passive solutions to mitigate indoor temperature fluctuations, improving therefore indoor comfort. In addition, the integration of photovoltaics to combat the gradual increase in energy consumption is highly increasing to meet the growing demand for energy. Using phase change material to improve thermal and electrical performances of building integrated photovoltaic systems and to reduce incoming heat energy indoors, simultaneously, were performed. Interestingly, it is highly recommended to integrate the building integrated photovoltaic phase change material systems on inclined roofs in order to perform the phase change material as preferred through a cyclic process. The peak temperature of the inclined and vertical building integrated photovoltaic systems decreased from 70.5°C and 41°C to 41.4°C and 31°C, respectively. Hence, a drop in average indoor daytime temperature where the peak indoor temperature has been reduced to about 4.5°C. The inclined and vertical building integrated photovoltaic systems’ DC power output, at midday, has been increased from 74.5 W to 108.5 W and 37.5 W to 38.5 W. Eventually, the use of phase change material decreased the thermal load leveling by 7%, 2% and 1.5% during the first three days, respectively, After the third day, the decrease of the thermal load leveling remained constant at 3%. Consequently, findings reveal that using phase change material could be an excellent solution to decrease indoor air temperature fluctuation and can bring higher temperature drops.

Nomenclature

Highlights

  1. The indoor air temperature variation remained cyclic from the third day.

  2. Inclined BIPV-PCM systems are highly recommended to perform a cyclic process.

  3. The use of PCM decreases the indoor air temperature fluctuation during the studied period.

Authors contributions

Meriem NOUIRA: Dr. engineer and contract assistant professor: Optimizing, analyzing, reviewing, investigation, validation, writing, interpreting, editing and performing all the findings and results. Analyzing the numerical results using the presented Methodology and Software.

Habib SAMMOUDA: Professor: review.

Neda AZIMI: Assistant Professor: review.

Disclosure statement

The presented research is a continuity of a research conference paper mentioned below and some data are taken from the following paper: https://ieeexplore.ieee.org/document/9624915

Additional information

Funding

This work did not receive funding from any source.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.