819
Views
27
CrossRef citations to date
0
Altmetric
Review

Insertable cardiac monitors: current indications and devices

, , &
Pages 45-55 | Received 26 Sep 2018, Accepted 05 Dec 2018, Published online: 11 Dec 2018
 

ABSTRACT

Introduction: Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded.

Areas covered: This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially available ICMs.

Expert commentary: The 2018 ESC Syncope guidelines have expanded the indications for an ICM to patients with inherited cardiomyopathy, inherited channelopathy, suspected unproven epilepsy, and unexplained falls. ICMs are also increasingly used for the detection of subclinical atrial fibrillation (AF) in patients with cryptogenic stroke. Whether treatment of subclinical AF (SCAF) with oral anticoagulation prevents recurrent stroke is yet unknown. The current generation of ICMs are smaller, easier to implant, have better diagnostics, and are capable of remote monitoring. The Reveal LINQ (Medtronic) is the smallest ICM and has the most extensive performance and clinical data. The BioMonitor 2 (Biotronik) is the largest ICM but has excellent R-wave amplitudes, longest longevity, and reliable remote monitoring. The Confirm Rx (Abbott) is capable to provide mobile data transmission enabled by a smartphone app. Future generation of ICMs will incorporate heart failures indices to facilitate remote monitoring of heart failure patients.

Declaration of interest

S.C. Yap has received a research grant from Medtronic. The authors have no other relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript.

Reviewer disclosures

A reviewer on this manuscript has disclosed that they are an employee of Medtronic, the manufacturer of some of the devices mentioned in the paper under review. Peer reviewers on this manuscript have no other relevant financial relationships or otherwise to disclose.

Additional information

Funding

This paper was not funded.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 99.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 570.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.