118
Views
0
CrossRef citations to date
0
Altmetric
Articles

Abridged validation of charm II screening tests for the detection of veterinary drug residues in fish farmed in Cameroon

, , , , , , & show all
Pages 1691-1704 | Received 15 Apr 2022, Accepted 24 Jul 2022, Published online: 03 Aug 2022
 

Abstract

The intensification of aquaculture in Cameroon requires efficient screening methods to control veterinary drug residues in fish. This is why the charm II radio receptor technique for the detection of antimicrobial residues in aquaculture fish initiated in Belgium was transferred to Cameroon according to Commission Decision 2002/657/EC. The validation parameters included the following tests: repeatability, reproducibility and robustness in addition to the mandatory characteristics, detection capability and specificity. Selected veterinary drug-free fish samples of tilapia (Oreochromis niloticus), catfish (Clarias gariepinus), carp (Cyprinus Carpio) and kanga (Heterotis niloticus) were spiked at different target concentrations with different antimicrobials (β-lactams, tetracycline, sulfonamides, macrolides and chloramphenicol). The detection capabilities (CCβ) were at MRPL (0.3 µg/kg for chloramphenicol), or below the regulatory limits in a range of 0.25–0.5 MRL with 0% false-negative results. β-lactams (penicillin G), tetracyclines (tetracycline, chloretetracycline and oxytetracycline) and macrolides (erythromycine A) were detected at half MRL (25, 50 and 100 µg/kg respectively), while sulfonamides (sulfamethazine) was detected at 25 µg/kg (0.25 MRL). The detection capabilities (CCβ) obtained were satisfactory as the cut-off factors (Fm) were less than the mean values of blank fish readings (B) (Fm < B). Furthermore, the method was applicable since the cut-off factor was less than the positivity threshold (Fm < T). The variability of the data under repeatability and reproducibility conditions was acceptable, with a relative standard deviation less than 15%. Results were unaffected by delaying the reading time from 0 h to 24 h after the addition of scintillation fluid, with a precision below 16%. Likewise, non-target drugs were not detected even at high concentrations (100 MRL) in a cross-reactivity study. From the overall results, the performance characteristics (detection capabilities, precision, robustness and specificity) were suitable and comparable to the initial validation results, indicating that the transfer to Cameroon laboratory was valid, the method was reliable and could be used in aquaculture fish quality monitoring programs in Cameroon.

Acknowledgments

We are thankful to Dr Tchuenchieu K. Dimitri Alex for the statistical analysis assistance and to the fish farmers for their collaboration.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

This work was supported by the International Atomic Energy Agency (IAEA) under the Coordinated Research Project (CRP) code D 52039, contract [no. 18832].

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 799.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.