Intraoperative ossicular loading with the Otologics fully implantable hearing device

, MD, &
Pages 360-364 | Received 11 Sep 2006, Published online: 08 Jul 2009
 

Abstract

Conclusions. Use of the recently introduced intraoperative loading instrumentation during surgery improves the coupling efficiency and consistency of a fully implantable hearing device to the ossicles and ultimately leads to better patient performance with the device. Background. Patient performance with an implantable hearing device is dependent on effective coupling of the implant to the middle ear ossicles. New intraoperative instrumentation aids the surgeon in coupling the implantable hearing device and consistently optimizes patient performance. Materials and methods. The middle ear transfer function for the Otologics MET Ossicular Stimulator (METFMET) is a measure of transducer coupling efficiency, defined as acoustic threshold (in dB HL) minus implant threshold (in dB MET). This transfer function was measured in the Otologics US Phase I Semi-Implantable Clinical Trial without intraoperative loading instrumentation and in the Otologics US Phase I Fully Implantable Clinical Trial with intraoperative loading instrumentation. The same operative techniques and transducer design were used in both studies. The theory of operation and surgical technique for using this instrumentation are described. Results. In the semi-implantable clinical trials, METFMET was −10 to −15 dB for frequencies above 1 kHz, and dropped to −15 to −20 dB for lower frequencies. Fully implantable clinical trial results were 10–20 dB better than the semi-implantable trial results, with less variability at all frequencies. These findings indicate more consistent and better coupling efficiency of the transducer to the ossicles.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 226.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.