Abstract
High‐performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of nadolol in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 230 and 300 nm, respectively. A mobile phase composed by acetonitrile‐water containing 0.1% triethylamine (15∶85 v/v) and pH adjusted to 4.6 with formic acid was used. The UVDS method was performed taken a signal at 279.5 nm. The correlation coefficient (r) obtained for both methods was 0.9999. The proposed methods are simple, precise, accurate, and can be used in routine analysis.
We acknowledge FAPESP (Fundação de Amparo à Pesquisa do Estado de São Paulo) and CNPq (Conselho Nacional de Pesquisa‐Brasil) for the financial support.