Experimental study on characteristics of sodium fire in a columnar flow with discontinuous injections

, , , &
Pages 1255-1262 | Received 06 Dec 2017, Accepted 18 Jun 2018, Published online: 12 Jul 2018

Figures & data

Figure 1. Experimental apparatus.

Figure 1. Experimental apparatus.

Figure 2. Distributions of measuring points in the test chamber space and the sodium collection plate (unit: millimeter).

Figure 2. Distributions of measuring points in the test chamber space and the sodium collection plate (unit: millimeter).

Figure 3. Temperature distributions in the typical longitudinal line in the Side A (T1–T28).

Figure 3. Temperature distributions in the typical longitudinal line in the Side A (T1–T28).

Figure 4. Temperature distributions at longitudinal heights (direction:T1–T28) in the test chamber space at various times.

Figure 4. Temperature distributions at longitudinal heights (direction:T1–T28) in the test chamber space at various times.

Figure 5. Tmax and corresponding tmax-T at different longitudinal heights (direction:T1–T28) in the test chamber space.

Figure 5. Tmax and corresponding tmax-T at different longitudinal heights (direction:T1–T28) in the test chamber space.

Figure 6. Temperature distributions of radial measuring points T21–T26 in the test chamber space.

Figure 6. Temperature distributions of radial measuring points T21–T26 in the test chamber space.

Figure 7. Temperature distributions of measuring points T28 and Td1.

Figure 7. Temperature distributions of measuring points T28 and Td1.

Figure 8. Average temperature distributions of all measuring points on different radii in the sodium collection plate.

Figure 8. Average temperature distributions of all measuring points on different radii in the sodium collection plate.

Figure 9. Pressure distributions in test chamber space.

Figure 9. Pressure distributions in test chamber space.

Figure 10. Heat release rate of sodium fire in a columnar flow with discontinuous injections.

Figure 10. Heat release rate of sodium fire in a columnar flow with discontinuous injections.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.