Abstract
This paper reports on a thermoluminescence study of D2O ice Ih. A sample of hexagonal (Ih) ice is irradiated by a 100 MeV X-ray source at 77 K. The emission spectrum that is measured immediately after the end of the irradiation process has the thermoluminescent behaviour of amorphous ice. The kinetic transition is followed to the stable form, taking place at 85 K. The relaxation time of the transition is of the order of 5 minutes. It is concluded that, due to irradiation, a few outer layers of ice Ih are converted to the low-density amorphous form of ice, which then converts to cubic ice. Although complex to quantify, thermoluminescence appears to be, in the present study, particularly sensitive to the time evolution of irradiated samples.
Keywords:
Acknowledgements
We wish to thank AREVA Marcoule Celestin Reactor and Laboratoires Boiron-Dolisos for their interest in and support of this research. We are also grateful for fruitful discussions with Dr. S. Le Caër during the preparation of the manuscript. The technical help of Sebastien Riegler has been deeply appreciated.