Generalized Procedure for Improved Accuracy of Thermal Contact Resistance Measurements for Materials With Arbitrary Temperature-Dependent Thermal Conductivity

Pages 433-438 | Published online: 24 Oct 2014
 

Abstract

Thermal contact resistance (TCR) is most commonly measured using one-dimensional steady-state calorimetric techniques. In these experimental methods, a temperature gradient is applied across two contacting beams and the temperature drop at the interface is inferred from the temperature profiles of the rods that are measured at discrete points. During data analysis, thermal conductivity of the beams is typically taken to be an average value over the temperature range imposed during the experiment. Here, a generalized theory is presented that accounts for temperature-dependent changes in thermal conductivity. The procedure presented enables accurate measurement of TCR for contacting materials whose thermal conductivity is any arbitrary function of temperature. For example, it is shown that the standard technique yields TCR values that are about 15% below the actual value for two specific examples of copper and silicon contacts. On the other hand, the generalized technique predicts TCR values that are within 1% of the actual value. The method is exact when thermal conductivity is known exactly and no other errors are introduced to the system.

NOMENCLATURE

c=

specific heat

c1, c2=

constants

k=

thermal conductivity

N=

number

q=

heat flux

=

volumetric heat generation rate

R=

thermal contact resistance

r2=

coefficient of determination

T=

temperature

t=

time

x=

position

Greek Symbols

ΔT=

temperature drop

θ=

transformed temperature

ρ=

density

σ=

standard deviation

=

normalized standard deviation

Subscripts

0=

reference

A=

specimen A

B=

specimen B

TC=

thermocouples

Additional information

Funding

Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

Notes on contributors

Robert A. Sayer

Robert A. Sayer is a senior research engineer at Sandia National Laboratories in Albuquerque, NM. He received his Ph.D. in mechanical engineering from Purdue University in 2011. He obtained his bachelor's degree in 2006 from The Ohio State University. His research interests include microscale and interfacial heat transfer, energy conversion, and material property measurement techniques. He is currently working on experimental measurement of thermal contact resistance and material thermal properties under extreme conditions.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 323.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.