240
Views
8
CrossRef citations to date
0
Altmetric
Original Articles

Experiments on Integral and Local Crystallization Fouling Resistances in a Double-Pipe Heat Exchanger With Wire Matrix Inserts

, , &
Pages 24-31 | Published online: 30 Jul 2015
 

Abstract

Wire matrix inserts are used in different applications of tubular heat exchangers to improve tube side heat transfer. They have also been used to suppress fouling in crude oil refining services. In this paper it is investigated whether the changed hydrodynamic and thermal conditions when applying wire matrix inserts have an impact on crystallization fouling compared to the plain tube. With a turbulent flow, at Reynolds number of 9877 and an inlet temperature of 42°C, fouling tests with an aqueous calcium sulfate solution for two wire matrix inserts with a different packing density were carried out and compared with a plain tube. Integral and local measurements of the fouling were performed. The experiments were realized in a double-pipe heat exchanger with a pipe length of 2000 mm. The integral fouling resistances between the inserts and the plain tube showed no significant difference, whereas major differences of the local fouling resistances were observed. Compared to the plain tube, the inserts showed an increased heat transfer up to a maximum of 35% but also a significantly increased pressure drop. Fouling on the inserts themselves, which was observed optically, is the possible explanation for this behavior.

NOMENCLATURE

A=

heat transfer area, m2

cF=

bulk phase concentration, mol/L

cP=

heat capacity, J/(kg-K)

d=

diameter, m

L=

length, m

LMDT=

logarithmic mean temperature difference, K

=

mass flow rate, kg/s

=

heat flow, W

=

heat flow density, W/m2

Pr=

Prandtl number cpμ/λ, dimensionless

Re=

Reynolds number based on the hydraulic diameter udh/μ, dimensionless

Rf=

fouling resistance, (m2-K)/W

Rov=

overall thermal resistance, (m2-K)/W

s=

wall thickness, m

t=

time, s

T=

temperature, K

u=

flow velocity, m/s

U=

overall heat transfer coefficient, W/(m2-K)

x=

local position, m

Greek Symbols

α=

heat transfer coefficient, W/(m2-K)

λ=

thermal conductivity of the liquid, W/(m-K)

λw=

thermal conductivity of the tube wall, 15 W/(m-K)

μ=

dynamic viscosity, Pa-s

Subscripts

0=

without fouling

f=

fouling

h=

hydraulic

i=

inlet

int=

integral

n=

segment number

m=

measurement point

o=

outlet

out=

outside

ss=

shell side

ts=

tube side

w=

wall

x=

axial position

Additional information

Notes on contributors

Robert Goedecke

Robert Goedecke is Ph.D. student at the Institute for Chemical and Thermal Process Engineering, Technische Universität Braunschweig, Germany. In 2010 he received his Dipl.-Ing. from Technische Universität Braunschweig. He worked on structural influences of crystallization fouling on heat transfer, and currently he is working on the experimental investigation of heat transfer and fluid dynamics in a pillow plate thermosiphon reboiler.

Peter Drögemüller

Peter Drögemüller works as research and development manager for Cal Gavin Ltd in the United Kingdom. His main research area is enhanced heat transfer in single- and two-phase flow applications. This includes research into suppression of fouling using tube-side enhancement technology. He is also responsible for software development, providing engineers with the opportunity to incorporate high-performance tube-side enhancement to the design of various types of tubular heat exchangers.

Wolfgang Augustin

Wolfgang Augustin is a senior researcher at the Institute for Chemical and Thermal Process Engineering, Technische Universität Braunschweig, Germany. He received his Dr.-Ing. in 1992 from Technische Universität Braunschweig. His main research interests are heat and mass transfer, fouling, viscous fluid flow, and surface interactions on the microscale level.

Stephan Scholl

Stephan Scholl is a professor of chemical and thermal process engineering at the Technische Universität Braunschweig, Germany. He received his doctorate degree in 1991 from the Technical University of Munich. After 11 years with BASF AG, Ludwigshafen, Germany, he joined Technische Universität Braunschweig in 2002. His main research areas are heat and mass transfer with an emphasis on fouling and viscous systems, separation processes in biotechnological applications, and process intensification.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 323.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.