The Reliability of Central Corneal Thickness Measurements by Ultrasound and by Orbscan System in Schoolchildren

, &
Pages 569-575 | Received 20 Jan 2006, Accepted 06 May 2006, Published online: 02 Jul 2009
 

Abstract

Purpose: To compare the central corneal thickness measurements obtained by ultrasound (US) pachymetry and the Orbscan II system in healthy schoolchildren. Methods: A total of 356 schoolchildren aged 7 to 12 years underwent central cornal thickness (CCT) measurement with Orbscan II and ultrasonic pachymetry. All eyes were examined first with the Orbscan II and then by US pachymetry. The mean of the difference, standard deviation (SD), and 95% limits of agreement, with and without applying the acoustic correction factor, were determined. The differences between the devices in measuring mean CCT were calculated with paired-sample t test. Pearson correlation test was used to determine the correlation between variables. p < 0.05 was considered to be statistically significant. Linear regression analysis was used to quantify the correlation between the two methods. Results: Orbscan II measurements were significantly higher than US pachymetry measurements without applying the manufacturer-recommended acoustic correction factor (0.92) correction (580.39 ± 37 μm and 562.95 ± 32 μm, respectively) (p < 0.0001). When this acoustic correction factor was applied, the Orbscan II measurements demonstrated significantly lower results when compared with those of US pachymetry (533.96 ± 34 μm and 562.95 ± 32 μm, respectively) (p < 0.0001). The linear regression analysis lines showed approximately 45-degree slope indicating a strong correlation between these methods (US pachymetry = 145.71 + 0.72 × Orbscan II value without acoustic correction factor (μm), r = 0.89, p < 0.0001). There was a high degree of variability in differences between the 2 devices in individual subjects. The range was between 25 to −55 μm without the acoustic correction factor and 67 to −5 μm with the acoustic correction factor. Conclusions: Although US pachymetry and Orbscan II demonstrated a strong linear correlation, there was a high degree of variability in differences between the two devices in individual subjects who participated.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 555.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.