Biometric Factors Associated with the Visual Performance of a High Addition Multifocal Intraocular Lens

, ORCID Icon, , &
Pages 998-1005 | Received 08 Feb 2018, Accepted 16 May 2018, Published online: 30 May 2018
 

ABSTRACT

Purpose/Aim: To evaluate the impact of ocular parameters on the visual performance achieved with the multifocal intraocular lens (IOL) Bi-Flex M 677MY.

Materials and Methods: About 26 subjects were included in the current study. Several physiological variables were retrieved from the 3-month follow-up visit, including pupil diameter and distance from pupil center to the vertex normal of the anterior cornea (µ). These variables were also obtained in the preoperative visit. Binocular and monocular visual acuity defocus curves were measured at 1 and 3 months after surgery, respectively. The monocular Area Under the Curve (AUC) was computed along the total range (Total Area Under the Curve (TAUC), +1.00 to −4.00 D) and for the ranges of Far (Far Area Under the Curve (FAUC), +0.50 to −0.50 D), (Intermediate Area Under the Curve (IAUC), −1.00 to −1.50 D) and Near vision (Near Area Under the Curve (NAUC), −2.00 to −4.00 D). Correlations between these areas and the postoperative physiological variables were assessed.

Results: The mean µ was reduced from 0.21 to 0.10 mm after surgery, as well as pupil diameters, either photopic (−7.4%) or mesopic (−8.1%) (p < 0.05). The mean AUCs were 2.08 ± 0.74 for TAUC, 0.57 ± 0.17 for FAUC, 0.16 ± 0.09 for IAUC, and 0.81 ± 0.29 for NAUC. Significant correlations were found between NAUC and corneal power  (r = −0.39, p = 0.05) as well as between IAUC and temporal decentration of the lens from vertex normal (ρ = −0.41, p = 0.04).

Conclusions: The visual performance at near distance with the IOL evaluated improved in eyes with less corneal power. On the other hand, a slight temporal IOL decentration from vertex normal also improved intermediate visual acuity. The binocular defocus curve was similar to other trifocal IOLs.

Acknowledgment

None.

Declaration of interest statement

MR-V has designed and programmed the Multifocal Lens Analyzer test used in the current study which is distributed by the Apple Store as well as the Refractive Analysis Toolbox for Matlab. The other authors report no conflicts of interest and have no proprietary interest in any of the materials mentioned in this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 555.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.