TABLE 1 Nephelometer models and specifications
FIG. 1 Schematic of the goniometer used to measure the angular illumination function of the nephelometer light sources in WCCAP2007.
![FIG. 1 Schematic of the goniometer used to measure the angular illumination function of the nephelometer light sources in WCCAP2007.](/cms/asset/22336a02-761e-4b8b-86e3-4c7bf442deaf/uast_a_380018_o_f0001g.gif)
FIG. 2 Angular intensity function, f(θ), including forward and backward truncation, for the TSI 3563, Radiance Research M903 and Ecotech 9003 nephelometers at green wavelengths. For comparison purposes, each function has been normalized to the area under the reference sine curve over the truncation angle range of the TSI instrument, 7 to 170 degrees.
![FIG. 2 Angular intensity function, f(θ), including forward and backward truncation, for the TSI 3563, Radiance Research M903 and Ecotech 9003 nephelometers at green wavelengths. For comparison purposes, each function has been normalized to the area under the reference sine curve over the truncation angle range of the TSI instrument, 7 to 170 degrees.](/cms/asset/79c45b3d-a73a-4de3-b9a2-28e1c033c16e/uast_a_380018_o_f0002g.jpg)
FIG. 3 Calculated generic correction factor, C ts , vs. D gv for three models of nephelometers accounting for truncation and angular illumination function of the light sources. The result of CitationAnderson and Ogren (1998) from the previous illumination function for the same aerosol parameters is shown for comparison.
![FIG. 3 Calculated generic correction factor, C ts , vs. D gv for three models of nephelometers accounting for truncation and angular illumination function of the light sources. The result of CitationAnderson and Ogren (1998) from the previous illumination function for the same aerosol parameters is shown for comparison.](/cms/asset/14e6ebf3-e1eb-41f9-b880-b0146bdd13fe/uast_a_380018_o_f0003g.jpg)
FIG. 4 Calculated generic correction factor, C ts , versus Ångström exponent for the TSI 3563, Radiance Research M903 and Ecotech 9003 nephelometers based on the WCCAP2007 angular illumination function. Results based on CitationAnderson and Ogren (1998) are shown for comparison. The horizontal bars show ranges of Ångström exponent from several regions of the globe as measured with a TSI three wavelength nephelometer (CitationAndrews 2004; CitationCarrico 2000; CitationDoherty 2005; CitationQuinn 2000; CitationSierau 2006).
![FIG. 4 Calculated generic correction factor, C ts , versus Ångström exponent for the TSI 3563, Radiance Research M903 and Ecotech 9003 nephelometers based on the WCCAP2007 angular illumination function. Results based on CitationAnderson and Ogren (1998) are shown for comparison. The horizontal bars show ranges of Ångström exponent from several regions of the globe as measured with a TSI three wavelength nephelometer (CitationAndrews 2004; CitationCarrico 2000; CitationDoherty 2005; CitationQuinn 2000; CitationSierau 2006).](/cms/asset/43eab018-28be-47cc-9769-17b081ceef78/uast_a_380018_o_f0004g.gif)