891
Views
3
CrossRef citations to date
0
Altmetric
Original Articles

Efficacy of aerosol reduction measures for dental aerosol generating procedures

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon show all
Pages 413-424 | Received 09 Oct 2021, Accepted 28 Jan 2022, Published online: 01 Mar 2022

Figures & data

Figure 1. (a) High-speed handpiece [HS]. (b) Piezoelectric ultrasonic scaler [PUS]. (c) High-speed handpiece with plastic high-volume evacuator [HS + HVE(P)]. (d) High-speed handpiece with metal high-volume evacuator [HS + HVE(M)]. (e) Four sampling positions: (1) Dentist, (2) Assistant, (3) 1 m, (4) 2 m. Notice air purifier placement to the right of patient’s feet. (f) Air purifier [AP]. (g) Particle counter.

Figure 1. (a) High-speed handpiece [HS]. (b) Piezoelectric ultrasonic scaler [PUS]. (c) High-speed handpiece with plastic high-volume evacuator [HS + HVE(P)]. (d) High-speed handpiece with metal high-volume evacuator [HS + HVE(M)]. (e) Four sampling positions: (1) Dentist, (2) Assistant, (3) 1 m, (4) 2 m. Notice air purifier placement to the right of patient’s feet. (f) Air purifier [AP]. (g) Particle counter.

Figure 2. Median dynamic aerosol concentrations measured at the dentist’s position: (a) high-speed handpiece [HS], (b) piezoelectric ultrasonic scaler [PUS], (c) control [CTL], (d, e) high-speed handpiece with high-volume evacuator (plastic/metal) [HS + HVE(P/M)], (f) high-speed handpiece with air purifier [HS + AP], (g) high-speed handpiece with plastic high-volume evacuator and air purifier [HS + HVE(P)+AP], (h) air purifier only [AP]. Color band represents the interquartile range. Median (IQR) increase ratio (RI˜) and reduction rate (RR˜).

Figure 2. Median dynamic aerosol concentrations measured at the dentist’s position: (a) high-speed handpiece [HS], (b) piezoelectric ultrasonic scaler [PUS], (c) control [CTL], (d, e) high-speed handpiece with high-volume evacuator (plastic/metal) [HS + HVE(P/M)], (f) high-speed handpiece with air purifier [HS + AP], (g) high-speed handpiece with plastic high-volume evacuator and air purifier [HS + HVE(P)+AP], (h) air purifier only [AP]. Color band represents the interquartile range. Median (IQR) increase ratio (RI˜) and reduction rate (RR˜).

Figure 3. (a) Change in aerosol concentration after 15 min. (b) Particle size distribution as measured at the dentist’s position at 15 min. More than 94.9% of particles were below 1.0 µm.

Figure 3. (a) Change in aerosol concentration after 15 min. (b) Particle size distribution as measured at the dentist’s position at 15 min. More than 94.9% of particles were below 1.0 µm.

Figure 4. Particle size distribution measured at the dentist’s position before and after interventions (n = 6).

Figure 4. Particle size distribution measured at the dentist’s position before and after interventions (n = 6).
Supplemental material

Supplemental Material

Download MS Word (808.8 KB)

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.