TABLE 1 Summary of comparisons between automated and filter-based measurements
TABLE 2 DemingFootnote a regression and Pearson correlation (r) results
TABLE 3 Minimum (Min.), maximum (Max.), mean (μ), and median (Med.) concentrations by comparison and method
FIG. 1 Comparison of the R&P 5400 TC to the RAAS TOT TC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression, and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 1 Comparison of the R&P 5400 TC to the RAAS TOT TC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression, and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/90f032ab-d617-4464-afcc-255fb7be908a/uast_a_9705924_o_f0001g.gif)
FIG. 2 Comparison of the R&P 5400 OC and RAAS TOT OC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 2 Comparison of the R&P 5400 OC and RAAS TOT OC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/d62ea7cd-0d16-4eea-b906-a250671bafb4/uast_a_9705924_o_f0002g.gif)
FIG. 3 Comparison of the R&P 5400 EC and RAAS TOT EC OC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 3 Comparison of the R&P 5400 EC and RAAS TOT EC OC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/dd7c1e6f-8916-4453-884e-f97d8e28f01d/uast_a_9705924_o_f0003g.gif)
FIG. 4 Difference in RAAS TOT and R&P 5400 measurements as a function of RAAS TOT concentration (μg C m−3) for (a) OC and (b) EC. The sampling period was 1 July through 2 October 2002. The number of samples for was (a) 26 and (b) 24.
![FIG. 4 Difference in RAAS TOT and R&P 5400 measurements as a function of RAAS TOT concentration (μg C m−3) for (a) OC and (b) EC. The sampling period was 1 July through 2 October 2002. The number of samples for was (a) 26 and (b) 24.](/cms/asset/f53c8701-122e-4a7d-ae73-1bfd10deafa7/uast_a_9705924_o_f0004g.gif)
FIG. 5 Comparison of Aethalometer BC and Andersen RAAS filter EC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 5 Comparison of Aethalometer BC and Andersen RAAS filter EC concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/a9f4c3f9-44a3-4f6a-b88e-da02e8101498/uast_a_9705924_o_f0005g.gif)
FIG. 6 Comparison of R&P 5400 EC and Aethalometer BC, without PM2.5 inlet (AETH BC) concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 6 Comparison of R&P 5400 EC and Aethalometer BC, without PM2.5 inlet (AETH BC) concentrations (μg C m−3) measured 1 July to 2 October 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/56f0eaa7-05c2-4e1e-8ef0-f8f820e88bf2/uast_a_9705924_o_f0006g.gif)
FIG. 7 Comparison of R&P 5400 EC and Aethalometer BC with PM2.5 inlet (AETH2.5) concentrations (μg C m−3) measured 23 November to 31 December 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.
![FIG. 7 Comparison of R&P 5400 EC and Aethalometer BC with PM2.5 inlet (AETH2.5) concentrations (μg C m−3) measured 23 November to 31 December 2002. The solid line represents the Deming linear regression and the dashed line represents the 1:1 line. The correlation (r), number of samples (N), and mean ratio are also shown.](/cms/asset/88222de2-845f-4460-9d8a-5b90ab961f90/uast_a_9705924_o_f0007g.gif)
FIG. 8 Difference in Aethalometer BC and 5400 EC as a function of Aethalometer BC concentration for (a) Aethalometer with the PM2.5 inlet and (b) Aethalometer without the PM2.5 inlet. The sampling period was 1 July through 2 October 2002, and the number of samples was (a) 558 and (b) 189. The sampling period was 23 November through 31 December 2002.
![FIG. 8 Difference in Aethalometer BC and 5400 EC as a function of Aethalometer BC concentration for (a) Aethalometer with the PM2.5 inlet and (b) Aethalometer without the PM2.5 inlet. The sampling period was 1 July through 2 October 2002, and the number of samples was (a) 558 and (b) 189. The sampling period was 23 November through 31 December 2002.](/cms/asset/5719e4af-5bf3-41ef-9560-7a5ae2ed5749/uast_a_9705924_o_f0008g.gif)