Validation of the Fitbit One, Garmin Vivofit and Jawbone UP activity tracker in estimation of energy expenditure during treadmill walking and running

, , , , &
Pages 208-215 | Received 18 Jun 2016, Accepted 20 Oct 2016, Published online: 05 Dec 2016
 

Abstract

Objectives: To determine the validity of energy expenditure estimation made by the Fitbit One, Garmin Vivofit and Jawbone UP activity trackers during treadmill walking and running. Determining validity of such trackers will inform the interpretation of the data they generate.

Design: Cross-sectional study.

Method: Fourteen adults walked at 0.70, 1.25, 1.80 ms−1 and ran at 2.22, 2.78, 3.33 ms−1 on a treadmill wearing a Fitbit One, Garmin Vivofit and Jawbone UP. Estimation of energy expenditure from each tracker was compared to measurement from indirect calorimetry (criterion). Paired t-tests, correlation coefficients and Bland–Altman plots assessed agreement and proportional bias. Mean percentage difference assessed magnitude of difference between estimated and criterion energy expenditure for each speed.

Results: Energy expenditure estimates from the Fitbit One and Garmin Vivofit correlated significantly (p< 0.01; r= 0.702; 0.854) with criterion across all gait speeds (0.70–3.33 ms−1). Fitbit One, Garmin Vivofit and Jawbone UP correlated significantly (p < 0.05; r = 0.729; 0.711; 0.591) with criterion across all walking speeds (0.70–1.80 ms1). However, only the Garmin Vivofit correlated significantly (p< 0.05; r = 0.346) with energy expenditure estimations from criterion across running speeds (2.22–3.33 ms1). Bland–Altman plots showed proportional bias for the Fitbit One and Garmin Vivofit. Energy expenditure estimations of single speeds were overestimated by the Fitbit One and underestimated by the Garmin Vivofit.

Conclusions: Energy expenditure reported by the devices distinguished between walking and running, with a general increase as exercise intensity increased. However, the reported energy expenditure from these devices should be interpreted with caution, given their potential bias and error.

    Practical implications

  • Although devices report the same outcome of EE estimation, they are not equivalent to each other and differ from criterion measurements during walking and running.

  • These devices are not suitable as research measurement tools for recording precise and accurate EE estimates but may be suitable for use in interventions of behaviour change as they provide feedback to user on trends in energy expenditure.

  • If intending to use these devices in studies where precise measurements of energy expenditure are required, researchers need to undertake specific validation and reliability studies prior to interventions and the collection of cross-sectional data.

Disclosure statement

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 706.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.