Correlation between time lag of arterial–plethysmographic waveforms and systemic vascular resistance: a prospective study

, , , , , , & show all
Pages 18-25 | Received 18 Jun 2017, Accepted 16 Nov 2017, Published online: 18 Dec 2017
 

Abstract

Blood pressure (BP), a surrogate of cardiac output (CO), is also dependent on systemic vascular resistance (SVR). But SVR is not routinely monitored in daily clinical practice. We hypothesise that the time difference between the peripheral arterial waveform and the finger plethysmographic waveform (time lag index - TLi) could indicate the systemic vascular resistance. In this study, we correlated TLi with the systemic vascular resistance measured by minimally invasive CO monitor (pulse contour analysis). SVR changes in response to administration of mannitol were studied. American Society of Anesthesiologists (ASA) class I and II patients undergoing major intracranial surgeries were recruited. Arterial cannulation and pulse-oximetry recordings were done in the same limb. Arterial and plethysmographic waveforms were recorded before mannitol infusion (baseline) and at every 10 minutes for 60 minutes after the termination of mannitol infusion. Simultaneously, SVR was recorded from the Vigileo FLotrac CO monitor. Using custom-made programme, the time difference between both waveforms was calculated and corrected for heart rate (TLi). The correlation between time lag and the systemic vascular resistance was assessed using a mixed effect model, adjusting for the subject. Data of one hundred subjects were analysed. Following mannitol administration, there was a significant decrease in the SVR and the TLi (p < .001). The patient characteristics influenced both the baseline values of SVR (intercept) and the changes in SVR over time (slope). As both the baseline value and the change over time for SVR were different in each patient, we used mixed effect model analysis to assess the relationship between SVR and TLi for different time periods. The effect of TLi on SVR was significant (β = 877.16, p = .008). The high beta coefficient suggests that when SVR increases, the TLi also increase and vice versa. A strong correlation between SVR and TLi was demonstrated for a given patient. Further studies are needed to explore the possibility of utilising this parameter to follow up changes in SVR in an individual patient at a particular point in time in different clinical scenarios.

Disclosure statement

None of the authors have any conflict of interests.

Additional information

Funding

The study was funded by Life Sciences Research Board – Defence Bio-Engineering & Electro Medical Laboratory (DEBEL), Defence Research and Development Organisation (DRDO), India [Grant number: DLS/81/48222/LSRB-243/BDB/2012].

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 706.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.