Identification of capillary blood pressure levels at which capillary collapse is likely in a tissue subjected to large compressive and shear deformations

&
Pages 59-71 | Received 14 Jul 2010, Accepted 08 Nov 2010, Published online: 21 Dec 2010
 

Abstract

Pressure ulcers (PU) are localised damage to skin and underlying tissues, caused by sustained tissue deformations and ischaemia. PU typically appear in insensitive or immobile patients, e.g. those with spinal cord injury (SCI) or geriatric patients. As these patients often experience fluctuations in blood pressure, and are also exposed to high-shear loads in their weight-bearing soft tissues during wheelchair sitting or bed rest, we used an inverse finite element method to determine the effects of capillary blood pressure (CBP) and shear deformations on occurrence of mechanical collapse in capillaries. We studied collapse in straight, U-shaped and bifurcated capillaries. All model configurations were consistent in demonstrating that the level of CBP has a considerable influence on the likelihood of capillary collapse in the physiological CBP range, particularly if shear is present. Our modelling therefore suggests that low CBP is a ‘suspect’ risk factor for PU in SCI and geriatric patients.

Notes

1. Submitted to a Special Issue of Computer Methods in Biomechanics and Biomedical Engineering on Identification of Material Parameters using Inverse Methods (Guest Editors: Drs. Stéphane Avril and Sam Evans)

2. In preliminary analyses, we tested the effects of using denser meshes for the capillary wall. Though denser meshes provided better resolution of the strain/stress distributions across the deformed wall, they did not affect the collapse behaviour of capillaries, in terms of the eccentricity parameter (Equation (Equation4)), and hence, for cost-effectiveness, it was decided to use a single layer of elements for meshing the capillary walls (Figure (c)). Likewise, using elements of higher order for the capillary wall (the element types that were used are specified in Table ) did not affect the behaviour of the eccentricity parameter.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.