145
Views
8
CrossRef citations to date
0
Altmetric
Research Article

Pulmonary targeting of sustained release formulation of budesonide in neonatal rats

, , , , &
Pages 680-686 | Received 30 Jan 2006, Accepted 28 Sep 2006, Published online: 08 Oct 2008
 

Abstract

Systemic corticosteroids are widely used for the treatment/prevention of chronic lung disease (CLD) in premature infants. The use of the inhalation route for delivering corticosteroids has been widely recognized, however so far pre-term babies continue to be treated with oral glucocorticoids, such as dexamethasone. We hypothesize that the pulmonary administration of sustained release formulations of inhaled corticosteroids to pre-term infants will result in a higher benefit/risk ratio as compared to traditional inhalation therapy. To achieve a slow release formulation budesonide particles were coated with a very thin film of polylactic acid using a pulse laser ablation technique. Coated material was characterized with respect to the dissolution behavior and particle size. Ex vivo receptor binding studies were performed to monitor the cumulative lung, liver and brain receptor occupancies after adminstration in neonatal (10–11 days old) rats after intratracheal instillation of either uncoated budesonide or poly (l-lactic acid) (PLA) coated budesonide. The mean dissolution timed for the uncoated and the polymer coated formulations were 1.2 ± 0.5 and 4.7 ± 0.1 h, respectively (p < 0.05). No significant differences in the respirable fraction were found between coated and uncoated formulation (p>0.05). The average receptor occupancies in the lung, liver and brain after administration of uncoated budesonide were 58.4 ± 12.9, 56.4 ± 6.8 and 38.3 ± 6.7%, respectively. However, after administration of PLA coated budesonide, the average AUC estimates in the lung, liver and brain were 75.8 ± 3.7%, 46.6 ± 14.5 and 29 ± 7, respectively. The results from our study suggest sustained receptor occupancy in the lungs of neonatal rats after administration of PLA coated budesonide results in lower systemic exposure (as indicated by low liver receptor occupancy). The data strongly underscore the urgent need to develop sustained release pulmonary-targeted delivery systems of corticosteroids for the treatment of CLD in pre-term infants. The administration of inhaled corticosteroids using targeted drug-delivery systems will potentially result in higher local effects and a reduction in systemic exposure.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 767.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.