Analytical quality by design approach versus conventional approach: Development of HPLC-DAD method for simultaneous determination of etizolam and propranolol hydrochloride

ORCID Icon, , , , , ORCID Icon, & show all
Pages 197-209 | Published online: 24 Jan 2021
 

Abstract

Considering the importance of robust analytics in the pharmaceutical industry, an analytical quality by design (AQbD) based reversed phase liquid chromatographic method was developed for the quantification of propranolol hydrochloride (PRO) and etizolam (ETZ). The developed method was validated and compared with an analytical method of conventional approach. In AQbD approach, analytical target profile (ATP) and risk assessment were tailored to identify critical method variables (CMVs) as inputs. Accordingly, pH (X1) % aqueous composition (X2), flow rate (X3) and % triethylamine (X4) were identified as CMVs and the respective retention time (Y1 and Y2) and theoretical plate (Y3 and Y4) for PRO and ETZ were set as method responses. The central composite design (CCD) predicted the scientific relationship between CMVs (Xn) and method responses (Yn). Then, the method operable design region (MODR) was arrived from systematic simulation and contour plots. There were six candidate methods selected from MODR and they demonstrated the r2 value > 0.9, thus the model proved its consistency for prediction. The robust range for the selected CMVs was derived from MODR, thus the ranges were 3–4 for pH, 30–35 for % aqueous composition, 0.9–1.1 mL min−1 for flow rate and 0.1–0.2 for % TEA buffer. Finally, the target AQbD method was optimized with pH; 3.5 (X1), 30% of aqueous composition in mobile phase with acetonitrile (X2), 0.9 mL min−1 of flow rate of (X3) and 0. 15% trimethylamine as buffer (X4) and further validated as per ICH Q2 guidelines. The result was compared with the conventional LC method with respect to specificity, accuracy, precision and robustness. The conventional HPLC method failed for robustness and showed relatively higher % RSD values than AQbD method.

Graphical Abstract

Acknowledgments

The authors are thankful to DST-FIST Facility of Raghavendra Institute of Pharmaceutical Education and Research, Anantapur, AP, India for the provided support.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Authors’ contributions

Ramalingam P and Jahnavi B conceptualize the work and drafted the manuscript Vinod Kumar K and Bhadrayya Kalva jointly designed and executed the experimental work, Sainath Gandhi K and Jagadeesh P performed laboratory experiments and Krishnaveni N drawn statistical conclusions and interpretation of results.

Data availability statement

Available.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 583.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.