317
Views
1
CrossRef citations to date
0
Altmetric
Preliminary Report

Synchronized Chest Compressions for Pseudo-PEA: Proof of Concept and a Synching Algorithm

Pages 721-729 | Received 02 Jun 2019, Accepted 05 Nov 2019, Published online: 19 Dec 2019
 

Abstract

Objective: The two objectives of this report are: first, to describe a comparison of chest compressions unsynchronized or synchronized to native cardiac activity in a porcine model of hypotension, and second, to develop an algorithm to provide synchronized chest compressions throughout a range of native heart rates likely to be encountered when treating PEA cardiac arrest. Methods: We adapted our previously developed signal-guided CPR system to provide compressions synchronized to native electrical activity in a porcine model of hypotension as a surrogate of PEA arrest. We describe the first comparison of unsynchronized to synchronized compressions in a single animal as a proof-of-concept. We developed an algorithm to provide optimal synchronized chest compressions regardless of intrinsic PEA heart rate while simultaneously maintaining the chest compression rate within a desired range. We tested the algorithm with computer simulations measuring the proportion of intrinsic and compression beats that were synchronized, and the compression rate and its standard deviation, as a function of intrinsic heart rate and heart rate jitter. Results: We demonstrate and compare unsynchronized versus synchronized chest compressions in a single porcine model with an intrinsic rhythm and hypotension. Synchronized, but not unsynchronized, chest compressions were associated with increased blood pressure and coronary perfusion pressure. Our synchronized chest compression algorithm is able to provide synchronized chest compressions to over 90% of intrinsic beats for most heart rates while maintaining an average compression rate between 90 and 140 compressions per minute with relatively low variability. Conclusions: Synchronized chest compression therapy for pulseless electrical rhythms is feasible. A high degree of synchronization can be maintained over a broad range of intrinsic heart rates while maintaining the compression rate within a satisfactory range. Further investigation to assess benefit for treatment of PEA is warranted.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 85.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.