Abstract
Conditioning of an aluminum-based water treatment sludge by single and dual polymers was investigated in this study. Capillary suction time (CST), specific resistance to filtration (SRF) and settling rate were used to evaluate the sludge dewatering characteristics. Sludge dewaterability resulting from single and dual polymer conditioning were compared for the purpose of exploring the validity and effectiveness of dual polymer conditioning strategy. Unlike activated sludge derived from wastewater treatment, results from this study have demonstrated that conditioning of the alum sludge by the combined use of an cationic polymer (FO-4140) followed by an anionic polymer (LT-25) does not exhibit considerable advantage in further improvement of sludge dewaterability with comparison of single polymer conditioning. This study supports the view that for aluminum-based water treatment sludge, inter particle bridging seems to be the dominative mechanism and the charge neutralization plays a less important role in the conditioning process. In addition, an intrinsic relationship between CST and SRF was deducted and tested via the experimental data obtained from the study.
Acknowledgment
The first author, Dr W. Ma, would like to thank the University College Dublin for providing his visiting scholarship via Strategic Initiative Fund.