Publication Cover
Journal of Environmental Science and Health, Part A
Toxic/Hazardous Substances and Environmental Engineering
Volume 46, 2011 - Issue 14
387
Views
5
CrossRef citations to date
0
Altmetric
ARTICLES

Comparison of anion removal capacities of Octolig® and Cuprilig

&
Pages 1619-1624 | Received 29 Mar 2011, Published online: 11 Nov 2011
 

Abstract

Mixtures of sodium salts of phosphate, arsenate, and fluoride were used in chromatography and batch experiments to compare the capacity of two immobilized ligands (IMLIGs) to remove these anions: Octolig® and its copper (II)-based metallolig, Cuprilig. The focus of this study was twofold. First, to find out which material, Octolig® or Cuprilig, would remove these anions most effectively; and secondly to determine the optimal capacity for removal of representative anions. Removal capacity was evaluated by two methods: by chromatography and by a batch method. The methods gave identical results, but the batch method was more convenient. Cuprilig had a lower capacity for removal of phosphate than Octolig®. The capability of Octolig® for removing anions was: phosphate > arsenate > fluoride >>>chloride >>>>bromide. Replication of phosphate removal was good for a given batch of Octolig®. Of three different samples of Octolig®, two seemed to be alike based on the phosphate- removal capacity; the third was different on the basis of a Student's t-test. This distinction indicates the batch procedure could serve as a quality control/assurance technique.

Acknowledgments

We appreciate technical assistance by Christopher Lizardi at early stages of this work. We thank an anonymous reviewer for helpful comments and suggestions. We also appreciate financial assistance of the USF Honors College, Dr. Naomi Yavneh, Associate Dean and Director, Undergraduate Research.

Notes

*Chromatography: 100 ppm aqueous samples through column (1.9 cm, i.d.) packed with Cuprilig (14, 21, 28 mL) at a rate of 10 mL/min (50-mL aliquots were collected. With the phosphate runs, 28 mL of Octolig® was used.

**Volumes of Cuprilig used were 40, 60, and 80 mL, respectively for the three assays.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 709.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.